System Operation
Power On
1.
Switch MAIN POWER on.
2.
Set heater air flow to 20-40 SCFH.
3.
Switch HEATER POWER on.
a.
When the temperature is not /- 3 degrees of the set point the error
message
“TEMPERATURE ERROR” will be displayed.
4. Position components to be processed within the thermal nozzle for a timed duration.
5. Remove the components from the thermal nozzle and position them at the end of the
Cooling air nozzle. Depress the foot switch or toggle, the panel switch will start the flow
of air.
Power Off
1.
Switch HEATER POWER off.
2.
Place the Nozzle Cover (shown below in Figure 5) over the Thermal Nozzle appliance, to
prevent heat related burns and/or injuries.
3.
Let the heater cool for approximately 5 minutes.
4.
Switch MAIN POWER off.
Note: Failure to let heater completely cool down will result in a shortened heater lifecycle.
Figure 5: Nozzle Cover