12
• "PROTOCOL"
:
voltage regulator protocol type ("BSS", "LIN").
• "VOLTAGE"
: voltage of "B+" terminal, V.
• "ERROR"
: potential errors in voltage regulator operation. The are 3 types of potential errors:
–
"EL"
: electric;
–
"МЕС"
: mechanic;
–
"ТН"
: thermal.
• "DFM"
: alternator load control indicator, %.
• "Volt.Reg"
: indicator of set voltage, Volt. The value is set with the buttons "⇧" and "⇩".
5.2 When testing voltage regulators
with "RLO", "SIG", "P-D", "C" terminals
• TERMINAL
:
voltage regulator testing mode
terminal. "RLO", "SIG", "P-D", "C" protocols are
displayed. The terminal designation depends on
the selected option in the menu.
• VOLTAGE
:
Voltage of "B+" terminal, V.
• DFM
:
alternator load control indicator, %.
• Vol. Reg
:
indicator of set voltage, Volt. The
value is set with the buttons "⇧" and "⇩".
5.3 Display data output in "PWM" mode (PWM generator)
• PWM, %
:
set of the duty cycle in percent,
varying from 0 to 100.
• FREQUENCY, Hz
: set of frequency, Hertz. Value
varies from 0 to 100. The required value is
set by pressing the pole with the number on
the touch screen. The value is set with the
buttons "⇧" and "⇩".