INSTALLATION INSTRUCTIONS
M S D I G N I T I O N
• w w w . m s d i g n i t i o n . c o m • ( 9 1 5 ) 8 5 7 - 5 2 0 0 • FA X ( 9 1 5 ) 8 5 7 - 3 3 4 4
Default SettINgS aND aDjuStMeNtS
The following list shows all of the default values and adjustable increment of the PN 7530 Ignition.
Display
Default
Data Low-High (step by)
ShiftLt1 ###00 Rpm
12,500
2,000-12,500 (100)
ShiftLt2 ###00 Rpm
12,300
2,000-12,500 (100)
ShiftLt3 ###00 Rpm
12,100
2,000-12,500 (100)
ShiftLt4 ###00 Rpm
11,900
2,000-12,500 (100)
ShiftLt5 ###00 Rpm
11,700
2,000-12,500 (100)
LastGear #
5
2-6
MagComp #.# Deg
2.0
0-3.0 (.5)
RevBurn ###00 Rpm
7,000
2,000-12,500 (100)
RevLaunch ###00 Rpm
6,200
2,000-12,500 (100)
RevMax ###00 Rpm
9,500
2,000-12,500 (100)
RetStart ## Deg
10
00-25
Retard1 ##.# Deg
2.0
0-15.0 (.5)
Retard2 ##.# Deg
3.0
0-15.0 (.5)
Retard3 ##.# Deg
5.0
0-15.0 (.5)
Retard1 ###00 Rpm
800
800-12,500 (100)
Retard2 ###00 Rpm
800
800-12,500 (100)
Retard3 ###00 Rpm
800
800-12,500 (100)
RetLaun ##.# Deg
0.0
0-15.0 (.5)
RampTim #.## Sec
.50
0-2.50 (.01)
Spark1 #.# Deg
0
0-5.0 (.1)
Spark2 #.# Deg
0
0-5.0 (.1)
Spark3 #.# Deg
0
0-5.0 (.1)
Spark4 #.# Deg
0
0-5.0 (.1)
Spark5 #.# Deg
0
0-5.0 (.1)
Spark6 #.# Deg
0
0-5.0 (.1)
Spark7 #.# Deg
0
0-5.0 (.1)
Spark8 #.# Deg
0
0-5.0 (.1)
CylCnt $
8
4/6/8
Distributor
Distributor
Distributor/CrankTrigger
DropRpm ##00
600
500-1500 (100)
RunCurve Rpm ###00
800
800-12500 (100)
RunCurve Deg ##.#
0
0.0-25.0 (.1)
LaunchCurve Rpm ###00
800
800-12500 (100)
LaunchCurve Deg ##.#
0
0.0-25.0
(.1)
StepOffDelay #.##
.50
0-2.50 (.01)
AlertsPer #
0
0-1
RpmSw On
2000
2000-12,500 (100)
RpmSw Off
6000
2000-12,500 (100)
Gear3 Retard Deg #.#
0
0.0-5.0 (.5)
Gear4 Retard Deg #.#
0
0.0-5.0 (.5)
Gear5 Retard Deg #.#
0
0.0-5.0 (.5)
Gear6 Retard Deg #.#
0
0.0-5.0 (.5)
ScanTime #Sec
1
1-9
CamSync $$$$
NONE/SYNC
Rpm ####
monitor
RetSum ##.#
monitor
ShiftLt $$
OFF/ON
LowBatt $$$
OK/LOW
Gear #
1-5
RpmSw $$$
OFF/ON
MaxCylDeg
0.0-5.0
TrigScr
NONE/MAG/PTS
Step1In
OFF/ON
Step2In
OFF/ON
Step3In
OFF/ON
RevLaunIn
OFF/ON
RevBurnIn
OFF/ON