background image

5. Canister: Make sure canister is clean. Never try to clean canister by wash-

ing it or using compressed air. Inspect canister for dents, scratches or other
damage.

Assemble Gas Mask as Follows:

Place canister onto inlet port carefully. Hand tighten by turning clockwise to
ensure a good seal against the gasket or facepiece.

DONNING THE MASK

1. Extend all headband straps.
2. Put you chin in first.
3. Grasp the two side straps in each hand, and pull the harness back over your

head.

4. To tighten straps, pull straight back, not out.
5. Adjust straps as necessary to position facepiece.

TEST FOR TIGHTNESS

THE FACEPIECE MUST BE SUBJECTED TO THE FOLLOWING TIGHTNESS
TEST BEFORE EACH USE. Test the mask facepiece for tightness by lightly
placing a palm over the inlet end of the canister. Inhale gently so that the face-
piece collapses slightly and hold breath for ten seconds. The facepiece will
remain collapsed while the breath is held providing the assembly is gas tight. If
any leakage is detected around the facial seal, readjust head harness straps
and repeat test until there is no leakage. If other than facial seal leakage is
detected, the condition must be investigated and corrected before another test
is made. The facepiece must pass the tightness test before the user should
attempt to enter any toxic atmosphere. The mask will not furnish protection
unless all inhaled air is drawn through the canister.

Do not enter any atmosphere with this respirator unless you KNOW that:
1. You have read, understood and followed all instructions and warnings

pertaining to the respirator.

2. The respirator and conditions meet the requirements outlined.
3. The canister is the proper type for the contaminant or contaminants

present.

4. The amount of oxygen is sufficient to support life (that is, at least 19.5

percent oxygen by volume at sea level). Do not use if oxygen concen-
tration sufficient to support life is questionable.

5. Respirator does not leak (see Test for Tightness).
6. Canister does not need to be replaced. Discard exhausted canister.

FAILURE TO FOLLOW ABOVE WARNINGS CAN

RESULT IN SERIOUS PERSONAL INJURY OR DEATH.

4

TAL 704 (L) Rev. 11 - 487373

WARNING

Summary of Contents for Phalanx Alpha

Page 1: ...under the 42 CFR 84 P100 classification 99 97 efficiency level against all particulate aerosols including oil based aerosols NIOSH approval See inside for instructions warnings and limitations See separate insert for NIOSH Approval Matrix Phalanx Alpha Phalanx Beta and Ultra Elite TAL 704 L Rev 11 MSA 2007 Print Spec 10005389 F Mat 487373 Doc 487373 ...

Page 2: ...es vapors NIOSH approved for CN chloroacetophenone and CS chlorobenzylidene malononitrile and all particulate aerosols including oil based aerosols listed on the canister label from the inhaled air Inhaled air is drawn through the canister which con tains chemicals and a P100 filter that removes or neutralizes the contaminants The air is then drawn through the facepiece where it passes over the le...

Page 3: ...w all warnings and limita tions specified Failure to do so can result in serious personal injury or death PREPARATIONS FOR USE There are five inspection points listed below that must be checked before donning the respirator Under no circumstances should a respirator that fails inspection be used The respirator must be repaired or replaced 1 Head harness Check to see that the head harness straps st...

Page 4: ...akage is detected around the facial seal readjust head harness straps and repeat test until there is no leakage If other than facial seal leakage is detected the condition must be investigated and corrected before another test is made The facepiece must pass the tightness test before the user should attempt to enter any toxic atmosphere The mask will not furnish protection unless all inhaled air i...

Page 5: ...This mask must be kept in good condition to function properly When any part shows evidence of failure it must be replaced immediately with the proper part CLEANING AND DISINFECTING The facepiece assembly with canister removed should be cleaned after each use with MSA Cleaner Disinfectant Liquid P N 697284 maximum 120 F 1 Immerse soiled equipment in the solution and scrub gently with a soft brush u...

Page 6: ... determine or check with the safety office to verify that the protective equipment to be used is sufficient for exposure to their particular hazard and contamination level Mis use of the protective equipment can result in serious personal injury or death During the Stay in the CBA Contaminated Area 1 It is recommended that the area be real timed monitored with alarm for exposure levels of the cont...

Page 7: ...Failure to follow accepted safety and protection procedures when exposed to hazardous atmospheres can result in serious personal injury or death WARNING TAL 704 L Rev 11 487373 7 ...

Page 8: ...8 TAL 704 L Rev 11 487373 817589 634323 ...

Page 9: ...634623 TAL 704 L Rev 11 487373 9 ...

Page 10: ...10 TAL 704 L Rev 11 487373 ...

Page 11: ...TAL 704 L Rev 11 487373 11 NOTES ...

Page 12: ......

Page 13: ...1 TAL 7921 L Rev 9 DRAFT 12 15 97 ...

Page 14: ...1 TAL 7921 L Rev 9 DRAFT 12 15 97 ...