background image

8

Disposal

Recycling of electrical and electronic equipment:

The crossed-out trash can symbol indicates that after the end of life this product should not be thrown
away with the normal trash. To prevent harm to the environment and human health from uncontrolled
waste disposal, do not throw this product together with normal trash and dispose of it with the
responsibility necessary to the use of material resources. For individuals to obtain information about
the rules of disposal in their territory local waste management department should be contacted.

19

GB

8 Disposal

Summary of Contents for M1

Page 1: ...Operating Manual M1 Repeater Telemetry System Order No 10220916 00 MSAsafety com ...

Page 2: ...sit https us msasafety com Trademarks This product incorporates Bluetooth wireless technology The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG Inc and any use of such marks by MSA is under license Other trademarks and trade names are those of their respective owners MSA Europe GmbH Schlüsselstrasse 12 8645 Rapperswil Jona Switzerland For your local MSA contacts pl...

Page 3: ...ion 8 3 2 Battery Installation 9 3 3 Battery Charging 10 4 Use 13 4 1 Powering On 13 4 2 Powering Off 13 4 3 Positioning the Antenna 13 4 4 Operation of Multiple Repeaters 13 4 5 Service Mode 14 5 Maintenance 15 5 1 Cleaning 15 5 2 Replacing the Battery 15 6 Troubleshooting 17 7 Storage 18 8 Disposal 19 9 Technical Data 20 10 Marking and Certification 21 10 1 Marking 21 10 2 Certification 21 11 Or...

Page 4: ... be verified The device must not be used if it is damaged Repair or alteration of the device beyond the procedures described in this manual or by anyone other than a person authorized by MSA could cause the unit to fail to perform properly Use only genuine MSA replacement parts when performing any maintenance procedures described in this manual Substitution of components can seriously impair perfo...

Page 5: ...cordance with the instructions in this manual 1 3 Warranty Local rules apply For any additional information relative to use or repair call 1 877 MSA FIRE 1 877 672 3473 during regular working hours or write an e mail to fire cs msasafety com For additional contact information refer to the MSA website at www MSAsafety com 5 GB 1 Safety Regulations ...

Page 6: ...epeater 1 RFID Asset Chip 4 Power button and power light LED 2 Battery holder 5 Antenna holder and guide 3 Connection status lights LEDs 6 Goose neck antenna 2 3 Connectivity The device automatically searches for a network connection and repeats signal in the telemetry system using Long Range Radio LRR For the connectivity status see 2 4 LED Status 6 GB 2 Description ...

Page 7: ...ottom of a staircase Sharp corner in a corridor or a tunnel Where the M1 Control Module loses radio connection to the hub see M1 Control Module operating manual on the product page at www MSAsafety com Make sure that minimum one repeater is within the range of the HUB In case of poor or loss of connection a repeater must be placed For more information on signal reception see Entry Control Board op...

Page 8: ...ay be damaged 3 1 Antenna Installation WARNING Antenna connection must be clean and dry prior to installation to prevent moisture or contaminants from entering the electrical connector area resulting in intermittent or unexpected loss of signal or damage to the device Failure to follow this warning can result in serious personal injury or death Assembling 1 Hand screw the antenna Disassembling 1 U...

Page 9: ...atteries Do not short circuit the batteries Do not overheat the batteries Do not open the batteries Do not deform the batteries Do not expose the batteries to water Do not modify the batteries Failure to follow this warning can result in serious personal injury or death 1 Remove the U clip from battery compartment completely using a flat tool 2 Insert the battery 10201874 3 Push the battery end do...

Page 10: ...rmittent or unexpected loss of power to the device Failure to follow this warning can result in serious personal injury or death To remove battery reverse the above installation procedure 3 3 Battery Charging Use the M1 Control Module charging adapter set the SCBA truck charger or the Multi Bay charger 11 Ordering Information For battery status condition see section 2 4 LED Status 10 GB 3 Before U...

Page 11: ... rechargeable battery or charging system to high temperature or heating equipment including but not limited to direct sunlight and water heaters Overheating may cause an explosion Do not drop crush or puncture the rechargeable battery or charging system Damage from such occurrences can lead to short circuit and overheating of the equipment Do not dispose of batteries in a fire Batteries can explod...

Page 12: ...sure the charging clip is aligned correctly and the contacts are free of dirt Device controls the charging process without user interaction Maximum charging time is four hours 2 Disconnect the charging clip after the charging process is complete For charging multiple batteries with the Multi Bay Charger follow the charger s user instructions 12 GB 3 Before Use ...

Page 13: ...ower LED lights up green NOTE When red remove battery If still fails replace the repeater Connection lights start to blink When radio signal is repeated the connection lights are constantly on 4 2 Powering Off Press the red power button The device is considered to be off when the power LED is off 4 3 Positioning the Antenna 1 Place the device on the ground NOTE Make sure that the device has full c...

Page 14: ...ted via Bluetooth using a special software application To access the service mode press the power button longer than 5 sec Power button LED is green and connection state LEDs are red 2 4 LED Status For further information see the A2 Software Operating Manual on the MSA Software Product website at www MSAsafety com 14 GB 4 Use ...

Page 15: ... Always use a damp cloth instead Avoid alcoholic and chemical detergents Otherwise the device will be damaged and the labels might be unreadable Periodically clean the exterior of the device with a damp cloth The device components should be cleaned after each operation and if badly contaminated with a damp cloth tepid water and a little detergent When cleaning the battery should always be connecte...

Page 16: ...ndensed water on the inner electronic contacts of the battery pack Clean the inner electronic contacts only dry without the help of chemical cleaning compounds Otherwise the full functionality of the device is not ensured For battery exchange see section 3 2 Battery Installation 16 GB 5 Maintenance ...

Page 17: ...al Remedy Power LED lights red Remove battery If failure still occurs after replacement contact a service technician Any other error Usage of the device is not recommended Return device to an MSA service center 17 GB 6 Troubleshooting ...

Page 18: ...evice to not perform as designed and approved Do not store the device for extended periods with the battery installed if the device is not intended for service If the device is in service ensure that the battery is charged Ensure the entire device is clean and dry Store the device in a cool dry place Always secure the device against moving or falling down during transport 18 GB 7 Storage ...

Page 19: ... trash To prevent harm to the environment and human health from uncontrolled waste disposal do not throw this product together with normal trash and dispose of it with the responsibility necessary to the use of material resources For individuals to obtain information about the rules of disposal in their territory local waste management department should be contacted 19 GB 8 Disposal ...

Page 20: ...without M1 Battery Pack 1775 g with M1 Battery Pack Ingress protection IP67 Max RF output power 27 dBm Power supply Battery powered by M1 Battery Pack 7 4 VDC 2 2 Ah Connectivity Bluetooth BR EDR LE Operation frequency range 2402 MHz 2480 MHz Max RF power 10 dbm 10 mW Telemetry radio Operation frequency range 469 93 MHz Max RF power 500 mW 20 GB 9 Technical Data ...

Page 21: ...g of Device ID e g A for main device B for battery pack etc Production year two digits e g 19 Production week two digits e g 06 Consecutive number e g 001 4 Address of manufacturer 10 2 Certification Approvals 0158 PPE EN 137 2007 type 2 DEKRA DEKRA Testing and Certification GmbH Notified Body number 0158 The Declaration of Conformity can be found under the following link https MSAsafety com DoC 2...

Page 22: ... Use None Quality Assurance Notification 0158 Year of Manufacture see Label Serial No see Label 2 W in ATEX fault condition Marking and Certificates according to IECEx Manufacturer MSA Europe GmbH Schlüsselstr 12 CH 8645 Rapperswil Jona Product M1 Repeater EU Type Examination Certificate IECEx BVS 21 0023 Standards IEC 60079 0 2017 IEC 60079 11 2011 Cor 2012 Marking II 1G Ex ia IIC T4 Ga 30 C Ta 6...

Page 23: ... battery 10201874 M1 Control Module Bat U clip 5 pcs 10201875 M1 Control Module Charging Adapter Set 10203487 Multi Bay Charger EU 10214753 Multi Bay Charger UK HK SG 10214754 Truck Charger 10220790 11 1 Spare Parts Description Part Number UK Telemetry Antenna 470 Mhz 10217282 SP 23 GB 11 Ordering Information ...

Page 24: ...For local MSA contacts please visit us at MSAsafety com ...