Maintenance manual
MSA, Châtillon sur Chalaronne • Tél. +33 (0)474 55 01 55 •
E-mail [email protected]
17
APPENDICES:
Replacement criteria
-
LH 050 PM and GM shell and fittings
Sub-elements
-
Defects
Criteria
-
Action
Shell
Cracks and/or
scratches
Aramid fibres damaged*
Replace
Aramid fibres
not damaged*
Nothing to report
Impacts
Height of fall > 1 m
Replace
Height of fall < 1 m
Nothing to report
Rail
Riveting
Defective
Replace
Attachment
Coming apart
Replace
Breakage
Defective
Replace
Wear
Defective
Replace
Chinstrap mount
Riveting
Defective
Replace
Attachment
Coming apart
Replace
Breakage
Defective
Replace
Wear
Defective
Replace
Edge seals
Attachment
Coming apart
Rebond with glue