Facepiece
The facepiece is available in 3 sizes (small, medium, large) and the nosecup is available in three sizes
(small, medium, large). The facepiece includes a large lens to optimize field of view. The facepiece
includes a mechanical speech diaphragm to enhance speech communication.
When the facepiece is not connected to a regulator, an opening in the facepiece connection allows
airflow to bypass the inhalation and exhalation valves, which decreases breathing resistance and
further enhances speech communication. The facepiece includes a broad range of head harness
design and material options. An optional spectacle kit is available.
2.2
Regulator
The regulator connects to the facepiece with a Push-To-Connect (PTC) connection. The regulator
connection includes two independent release buttons.
The regulator is available with two cover options (purge, solid). The purge cover allows users to manu-
ally activate the regulator or deliver a quick burst of air. The regulator includes a bypass valve with a
large and easily accessible bypass knob.
The regulator hose is available in three options (continuous, threaded, quick connect). The continuous
hose provides an uninterrupted connection from the pressure reducer to the regulator. The threaded
and quick connect hose options include a connection positioned on the chest to improve hose maneu-
verability and provide a hose separation point to simplify regulator removal for testing or repair.