background image

NOTE:

For rescue belts, pouch must 

be attached to the quick-release strap 
on the backside for the FireHawk 
Rescue Belt II (or to the auxiliary strap 
for the Rescue Belt I)

Placing the regulator holder on the quick-release straps of the 
FireHawk Rescue Belt II will impede the use of the quick-release 
function of the rescue belt. Failure to follow this warning can result 
in serious personal injury or death.

NOTE:

For rescue belts, the regulator 

holder must be moved from the 
auxiliary strap to the waist belt.

NOTE:

For swiveling lumbar pads 

found on the AirHawk II Air Masks 
or NFPA 1981, 2002 Edition air masks, 
the left waist belt pull-strap must be 
routed as shown.

12. Coil the ExtendAire II System

manifold and hose and insert
into the pouch. Orient the
manifold so that it is near the
opening of the pouch.

13. Close the pouch and snap all

three (3) snaps closed.

DO NOT pressurize the system until all hoses and fittings are 
properly secured with u-clips. Pressurizing the system with 
unsecured hoses can cause the hoses to release explosively. 
Properly install and secure all hoses and fittings before pressuring 
the system. Failure to follow this warning can result in serious 
personal injury or death.

Checking for Leaks and Proper Operation

The air mask must hold system pressure without leaks to provide
adequate protection.
1.

Pressurize the air mask by attaching the Audi-Larm Audible Alarm
Assembly to a fully charged cylinder.

2.

Close the bypass on the Firehawk Second Stage Regulator and
open they cylinder valve completely. The FireHawk M7 Control
Module or pressure gauge will indicate the pressure of the
system.

3.

Close the cylinder valve and watch the FireHawk M7 Control
Module or pressure gauge. There should not be a drop in
pressure if the system is leak tight. (The maximum allowable
pressure drop is 100 psi in 10 seconds)

4.

If there is a noticeable decrease in pressure, a leak test is required

before using the air mask.

REPAIR AND SERVICE

The repair and service of the ExtendAire II Intermediate Pressure
Accessory Kit is designated by MSA as end user serviceable.
The following repairs require that the cylinder be disconnected
from the air mask. For additional illustrations and supplemental
instructions, refer to the 

Installing the ExtendAire II Intermediate

Pressure Accessory Kit

section of this manual.

Replacing the Dust Cover

To replace the dust cover, the ExtendAire II Dust Cover Kit, P/N
10111351, is required.
1.

Remove the two (2) screws in the first stage regulator bracket and
remove the PR14 First Stage Regulator. Do not remove the
regulator bracket from the backplate. Discard the screws.

2.

Remove the lower u-clip and the ExtendAire II emergency
breathing hose from the PR14 First Stage Regulator.

3.

Remove the ExtendAire II emergency breathing hose from the
hose restraint and from the pouch.

"

WARNING

"

WARNING

MSA 419 (L) Rev. 5 - 10110648

ExtendAire II Repair and Service

7

Summary of Contents for ExtendAire II

Page 1: ...nd serviced according to the instructions otherwise the respirator could fail to perform as designed and persons who rely on the air mask could sustain serious personal injury or death WARNING The war...

Page 2: ...ovalwhiletransfillinganddoesnotexhibitthe abovehazards INSPECTIONBEFOREUSE 1 EmergencyBreathingHose a InspectthehoseconnectionstothePR14 FirstStageRegulator andthehosemanifold Ensurethatthehoseisprope...

Page 3: ...atorhose c Ifthesecondairmaskdoes nothavetheExtendAireII IntermediatePressure AccessoryKitanddoes not havetheExtendAire IntermediatePressure AccessoryKit butdoeshavea FirehawkSecondStage Regulatorwith...

Page 4: ...d Attemptingtodisassembleapressurizedairmaskcan causepartstobecomeairborneorswingatveryhighratesofspeed Failuretofollowthiswarningcanresultinseriouspersonalinjuryor death 1 Removethecylinderfromthebac...

Page 5: ...NFPA 1981 2002Editioncompliantairmasks 7 Feedthehoserestraintstrapunderthehighpressurehoseand powercable thenattachthehoserestrainttothebackplateas describedbelow Forairmaskswithswivelinglumbar padorF...

Page 6: ...fvalve 4 Insertthehoseintotheportthat previouslycontainedtherelief valveinthefirststageregulator andreinstalltheu clip 5 InstallthePR14FirstStageRegulatorintothebracket Installtwo 2 newscrewsandtighte...

Page 7: ...rizetheairmaskbyattachingtheAudi LarmAudibleAlarm Assemblytoafullychargedcylinder 2 ClosethebypassontheFirehawkSecondStageRegulatorand opentheycylindervalvecompletely TheFireHawkM7Control Moduleorpres...

Page 8: ...nof thismanualforadditionalhelp 5 Beforeinstallingthehoseintothefirststageregulator replacethe o ringonthehosefittingwiththenewo ringprovidedinthe replacementkit ApplyChristo Lubetotheo ring Insertthe...

Page 9: ...ction pour laquelle il a t con u et les personnes dont la s curit en d pend pourraient subir des blessures graves ou mortelles AVERTISSEMENT Les garanties offertes par MSA relatives au produit sont an...

Page 10: ...euvent tre suivies ou pour offrir plus de protection pendant l vacuation utiliser le syst me remplissage rapide Quick Fill Il maintient son approbation pendant le transvidage et ne comporte pas les ri...

Page 11: ...le connexion rapide du tuyau respiratoire d urgence peut tre raccord au raccord m le connexion rapide du collecteur en ligne du tuyau de d tendeur de deuxi me tage du FireHawk c Si le deuxi me masque...

Page 12: ...esse N gligercet avertissementpeutentra nerdesblessuresgravesoumortelles 1 Enlever la bouteille de la plaque dorsale 2 Enlever la courroie tirer de la boucle de friction de la courroie d paule gauche...

Page 13: ...tenue du tuyau sous le tuyau de haute pression et le c ble d alimentation puis fixer la courroie de retenue du tuyau la plaque dorsale comme il est d crit ci dessous Pour les masques air munis d un ce...

Page 14: ...deur de premier tage et r installer le clip en U 5 Installer le d tendeur de premier tage PR14 sur le support Placer les deux 2 nouvelles vis et les visser un couple de 4 5 Nm 35 45 po lb 6 Faire pass...

Page 15: ...ournir une protection ad quate 1 Pressuriser le masque air en fixant l ensemble de l alarme sonore Audi Larm une bouteille compl tement pleine 2 Fermer la vanne de d rivation du d tendeur de second ta...

Page 16: ...erm diaire ExtendAire II dans ce manuel pour obtenir de l aide suppl mentaire 5 Avant d installer le tuyau dans le d tendeur de premier tage remplacer le joint torique du raccord du tuyau par le nouve...

Page 17: ...ionar correctamente y las personas que dependen de la m scara de aire podr an sufrir lesiones personales graves o la muerte ADVERTENCIA Las garant as otorgadas por la compa a MSA con respecto a este p...

Page 18: ...to para la conexi n en ambientes CBRN qu micos biol gicos radiol gicos y nucleares NOTA Si no es posible seguir las instrucciones anteriores o desea mayor protecci n durante el escape use el Sistema Q...

Page 19: ...os de presi n intermedia ExtendAire en la l nea con una manguera del Regulador de la segunda etapa FireHawk El accesorio hembra de conexi n r pida de la manguera de respiraci n de emergencia se puede...

Page 20: ...las piezas salgan despedidas u oscilen a velocidades muy altas El no seguir esta advertencia puede ocasionar lesiones personales graves o la muerte 1 Retire el cilindro de la placa de apoyo 2 Quite la...

Page 21: ...002 7 Pase la correa de sujeci n de la manguera por debajo de la manguera de alta presi n y el cable de energ a luego conecte la sujeci n de la manguera a la placa de apoyo como se describe a continua...

Page 22: ...v lvula de alivio en el regulador de la primera etapa y vuelva a instalar la grapa en U 5 Instale el regulador de la primera etapa PR14 en el soporte Instale 2 dos tornillos nuevos y ajuste a 4 a 5 Nm...

Page 23: ...cuada 1 Presurice la m scara de aire conectando la Unidad de alarma sonora Audi Larm a un cilindro totalmente cargado 2 Cierre la v lvula de derivaci n del regulador de la segunda etapa FireHawk y abr...

Page 24: ...intermedia ExtendAire II de este manual para obtener ayuda adicional 5 Antes de instalar la manguera en el regulador de la primera etapa cambie la junta t rica del accesorio de la manguera por la nuev...

Reviews: