background image

MSA 419 (L) Rev. 5                                        © MSA 2014                                     Prnt. Spec. 10000005389(I)  Mat. 10110648              

Doc. 10110648

ExtendAire

TM

II 

Intermediate Pressure Accessory Kit for use with the 

FireHawk

TM

M7 and AirHawk

TM

II Air Masks only.

USER INSTRUCTIONS

This manual must be carefully read and followed by all persons who have, or will have, the responsibility
for using or servicing this air mask. These air masks will perform as designed only if used and serviced
according to the instructions; otherwise, the respirator could fail to perform as designed, and persons who
rely on the air mask could sustain serious personal injury or death.

"

WARNING

The warranties made by MSA with respect to the product are voided if the product is not installed, used and
serviced in accordance with the instructions in this manual. Please protect yourself and your employees by
following the instructions. Please read and observe the WARNINGS and CAUTIONS inside. For any additional
information relative to use or repair, write or call 1-877-672-3473 during regular working hours.

Summary of Contents for ExtendAire II

Page 1: ...nd serviced according to the instructions otherwise the respirator could fail to perform as designed and persons who rely on the air mask could sustain serious personal injury or death WARNING The war...

Page 2: ...ovalwhiletransfillinganddoesnotexhibitthe abovehazards INSPECTIONBEFOREUSE 1 EmergencyBreathingHose a InspectthehoseconnectionstothePR14 FirstStageRegulator andthehosemanifold Ensurethatthehoseisprope...

Page 3: ...atorhose c Ifthesecondairmaskdoes nothavetheExtendAireII IntermediatePressure AccessoryKitanddoes not havetheExtendAire IntermediatePressure AccessoryKit butdoeshavea FirehawkSecondStage Regulatorwith...

Page 4: ...d Attemptingtodisassembleapressurizedairmaskcan causepartstobecomeairborneorswingatveryhighratesofspeed Failuretofollowthiswarningcanresultinseriouspersonalinjuryor death 1 Removethecylinderfromthebac...

Page 5: ...NFPA 1981 2002Editioncompliantairmasks 7 Feedthehoserestraintstrapunderthehighpressurehoseand powercable thenattachthehoserestrainttothebackplateas describedbelow Forairmaskswithswivelinglumbar padorF...

Page 6: ...fvalve 4 Insertthehoseintotheportthat previouslycontainedtherelief valveinthefirststageregulator andreinstalltheu clip 5 InstallthePR14FirstStageRegulatorintothebracket Installtwo 2 newscrewsandtighte...

Page 7: ...rizetheairmaskbyattachingtheAudi LarmAudibleAlarm Assemblytoafullychargedcylinder 2 ClosethebypassontheFirehawkSecondStageRegulatorand opentheycylindervalvecompletely TheFireHawkM7Control Moduleorpres...

Page 8: ...nof thismanualforadditionalhelp 5 Beforeinstallingthehoseintothefirststageregulator replacethe o ringonthehosefittingwiththenewo ringprovidedinthe replacementkit ApplyChristo Lubetotheo ring Insertthe...

Page 9: ...ction pour laquelle il a t con u et les personnes dont la s curit en d pend pourraient subir des blessures graves ou mortelles AVERTISSEMENT Les garanties offertes par MSA relatives au produit sont an...

Page 10: ...euvent tre suivies ou pour offrir plus de protection pendant l vacuation utiliser le syst me remplissage rapide Quick Fill Il maintient son approbation pendant le transvidage et ne comporte pas les ri...

Page 11: ...le connexion rapide du tuyau respiratoire d urgence peut tre raccord au raccord m le connexion rapide du collecteur en ligne du tuyau de d tendeur de deuxi me tage du FireHawk c Si le deuxi me masque...

Page 12: ...esse N gligercet avertissementpeutentra nerdesblessuresgravesoumortelles 1 Enlever la bouteille de la plaque dorsale 2 Enlever la courroie tirer de la boucle de friction de la courroie d paule gauche...

Page 13: ...tenue du tuyau sous le tuyau de haute pression et le c ble d alimentation puis fixer la courroie de retenue du tuyau la plaque dorsale comme il est d crit ci dessous Pour les masques air munis d un ce...

Page 14: ...deur de premier tage et r installer le clip en U 5 Installer le d tendeur de premier tage PR14 sur le support Placer les deux 2 nouvelles vis et les visser un couple de 4 5 Nm 35 45 po lb 6 Faire pass...

Page 15: ...ournir une protection ad quate 1 Pressuriser le masque air en fixant l ensemble de l alarme sonore Audi Larm une bouteille compl tement pleine 2 Fermer la vanne de d rivation du d tendeur de second ta...

Page 16: ...erm diaire ExtendAire II dans ce manuel pour obtenir de l aide suppl mentaire 5 Avant d installer le tuyau dans le d tendeur de premier tage remplacer le joint torique du raccord du tuyau par le nouve...

Page 17: ...ionar correctamente y las personas que dependen de la m scara de aire podr an sufrir lesiones personales graves o la muerte ADVERTENCIA Las garant as otorgadas por la compa a MSA con respecto a este p...

Page 18: ...to para la conexi n en ambientes CBRN qu micos biol gicos radiol gicos y nucleares NOTA Si no es posible seguir las instrucciones anteriores o desea mayor protecci n durante el escape use el Sistema Q...

Page 19: ...os de presi n intermedia ExtendAire en la l nea con una manguera del Regulador de la segunda etapa FireHawk El accesorio hembra de conexi n r pida de la manguera de respiraci n de emergencia se puede...

Page 20: ...las piezas salgan despedidas u oscilen a velocidades muy altas El no seguir esta advertencia puede ocasionar lesiones personales graves o la muerte 1 Retire el cilindro de la placa de apoyo 2 Quite la...

Page 21: ...002 7 Pase la correa de sujeci n de la manguera por debajo de la manguera de alta presi n y el cable de energ a luego conecte la sujeci n de la manguera a la placa de apoyo como se describe a continua...

Page 22: ...v lvula de alivio en el regulador de la primera etapa y vuelva a instalar la grapa en U 5 Instale el regulador de la primera etapa PR14 en el soporte Instale 2 dos tornillos nuevos y ajuste a 4 a 5 Nm...

Page 23: ...cuada 1 Presurice la m scara de aire conectando la Unidad de alarma sonora Audi Larm a un cilindro totalmente cargado 2 Cierre la v lvula de derivaci n del regulador de la segunda etapa FireHawk y abr...

Page 24: ...intermedia ExtendAire II de este manual para obtener ayuda adicional 5 Antes de instalar la manguera en el regulador de la primera etapa cambie la junta t rica del accesorio de la manguera por la nuev...