PREPARING THE RESPIRATOR FOR USE

6. Ensure proper engagement by pulling on the regulator

to verify that the regulator is securely attached to
facepiece.

DO NOT use the FireHawk M7 Responder APR unless
the regulator is properly connected. A regulator that is
not installed properly can separate from the facepiece
unexpectedly. Return the FireHawk M7 Responder
APR to an MSA trained or certified repairperson to
correct this condition. Failure to follow this warning
can result in serious personal injury or death.

INSTALLING THE BREATHING TUBE

1. Thread the elbow end

of the breathing tube
to the lens receptacle
on the mask.

DO NOT cross thread the breathing tube elbow to the
lens receptacle. The breathing tube will not seal to
the facepiece allowing contaminates to enter the res-
pirator. Failure to follow this warning can result in
serious personal injury or death.

2. Hand-tighten the elbow onto the mask.

3. Verify the canister gas-

ket is in the canister
connector assembly on
the breathing tube is in
place. The canister
gasket is green.

INSTALLING/REPLACING THE CANISTER

Know the contaminant(s) in the environment before
entering. Always check that the filter canister is
appropriate for use in the environment. A canister
which is not designed for the contaminant present
may not provide protection. Failure to follow this
warning can result in serious personal injury or death.

After verifying that the canister type is appropriate for
use in the environment:

1. Verify shelf life expiration date on carton, bag, and

canister label has not been exceeded.

DO NOT use an expired canister. Failure to follow this
warning can result in serious personal injury or death.
DO NOT use the canister if the bag is opened, dam-
aged, or missing. The canister must be in its original
packaging prior to use in a contaminated environment.
Do not reuse the canister. Failure to follow this warn-
ing can result in serious personal injury or death.

2. Remove canister from its packaging.
3. Inspect the canister to be sure that it is not damaged.

The canister gasket must be in place in the breathing
tube canister connector assembly when a canister is
installed. Failure to follow this warning can result in
serious personal injury or death.

4. Thread the canister into the canister connector

assembly and hand tighten.

Use the canister immediately upon opening the bag.

Discard canister after each use.

Replace the canister after each use. Follow the estab-
lished canister change-out schedules to ensure that can-
ister are replaced before breakthrough occurs. When used
at defined occupational exposure limits, the rated service
time cannot be exceeded.

All repair and replacement of subassemblies must be
carried out by a MSA certified repair technician.
Failure to follow this warning will void NFPA and
NIOSH certifications and can result in serious person-
al injury or death.

13

TAL 803 (L) Rev. 0 - 10086002

Summary of Contents for 10086004

Page 1: ...rsons who rely on the FireHawk M7 Responder APR could sustain serious personal injury or death WARNING OPERATION AND INSTRUCTIONS The warranties made by MSA with respect to the product are voided if t...

Page 2: ...ogical and nuclear dust particles Procedures for monitoring radiation expo sure and full radiation protection must be followed Z If during use and unexpected hazard is encoun tered such as a secondary...

Page 3: ...ction with personal protective ensem bles that provide appropriate levels of protection against dermal hazard Failure to do so may result in personal injury even when the respirator is fitted properly...

Page 4: ...NOTES 4 TAL 803 L Rev 0 10086002...

Page 5: ...ear glasses install the spectacle kit 15 The user must perform a respirator fit test Quantitative Test or Qualitative Test and follow all warnings and limitations specified 16 Wear impermeable protect...

Page 6: ...NOTES 6 TAL 803 L Rev 0 10086002...

Page 7: ...esent B The limitations outlined in the applicable NIOSH approval C Any applicable limitation contained in a standard established by regulatory agency such as OSHA with jurisdiction over the wearer An...

Page 8: ...Governmental Industrial Hygienists ACGIH Occupational Safety and Health Administration OSHA National Institute for Occupational Safety and Health NIOSH American Industrial Hygiene Association AIHA Co...

Page 9: ...sure seal test before the user attempts to enter a toxic atmosphere The facepiece will not furnish protection unless all inhaled air is drawn through a suitable canister RESPIRATOR FIT TEST The user m...

Page 10: ...NOTES 10 TAL 803 L Rev 0 10086002...

Page 11: ...ring 4 Starting at the top stretch and push the rubber ring of the nose cup under the plastic retainer ring of the speaking diaphragm assembly 5 Continue stretching around nosecup ring and work it in...

Page 12: ...sliding the strap through the slide It may be nec essary to use a ratcheting motion to completely tight en the strap Note canister connector is opposite the 90 degree elbow connection 4 For Configura...

Page 13: ...esult in serious personal injury or death After verifying that the canister type is appropriate for use in the environment 1 Verify shelf life expiration date on carton bag and canister label has not...

Page 14: ...e with C420 motor blower Refer to the NIOSH approval label for approved configurations In addition to this man ual the FireHawk M7 Responder PAPR manual P N 10086003 must be carefully read and followe...

Page 15: ...har ness back over the head 3 Pull the back of the harness downward until it is centered at the back of the head 4 Tighten the two lower straps first by pulling them straight back not out Tighten the...

Page 16: ...eal during use If adjusting the neck strap does not relieve the tension in the breathing tube a longer length breath ing tube can be used Failure to follow this warning may result in serious personal...

Page 17: ...can result in seri ous personal injury or death Donning the FireHawk M7 Responder PAPR For Donning and negative pressure seal test Instructions refer to the FireHawk M7 Responder PAPR User s Instructi...

Page 18: ...NOTES 18 TAL 803 L Rev 0 10086002...

Page 19: ...formed Disposal is to be performed as required by feder al state and or local laws PROCEDURE FOR REMOVING THE RESPIRATOR 1 Remove strap from around the neck and support the canister 2 To remove the f...

Page 20: ...NOTES 20 TAL 803 L Rev 0 10086002...

Page 21: ...ghly wash the facepiece drink tube and nosecup and breathing tube in the cleaning solu tion A soft brush or sponge can be used to clean the soiled facepiece f Rinse the facepiece and components in cle...

Page 22: ...NOTES 22 TAL 803 L Rev 0 10086002...

Page 23: ...a Inspect the breathing tube for cracks tears and dirt b Inspect the canister connector assembly gasket for cracks tears dirt and distortion 4 Inspect the speaking diaphragm a Inspect speaking diaphra...

Page 24: ...NOTES 24 TAL 803 L Rev 0 10086002...

Page 25: ...N 805029 with the lens cover label P N 10082547 and lens plug P N 10082476 attached The bag is provided as a convenient storage container to protect the facepiece Replace the bag if it becomes dam age...

Page 26: ...NOTES 26 TAL 803 L Rev 0 10086002...

Page 27: ...approved in a CBRN application and must NOT be used Failure to follow this warning can result in serious personal injury or death Some canteens may not be leak tight Canteens used with the hydration...

Page 28: ...ist along the edge of the elastic 6 Conduct a successful negative pressure seal test 7 Attach each of the arm straps to the front of the hood shroud using the Velcro attachment pads Adjust the arm str...

Page 29: ...n place 5 To remove the spark cover gently squeeze the outside of the cover twist and pull the spark cover off 6 Check the spark cover before each use to ensure no sparks have created holes or warped...

Page 30: ...NOTES 30 TAL 803 L Rev 0 10086002...

Page 31: ...se User s Instructions Below is a list of these other configurations and the part number for the User s Instructions Review the NIOSH matrix to verify the con figuration that is being used is an appro...

Page 32: ...representative of MSA may bind MSA to any affirmation representation or modification of the warranty concerning the goods sold under this con tract MSA makes no warranty concerning compo nents or acce...

Reviews: