MS Sedco TDM Installation Instructions Manual Download Page 2

io

Wet/Dry

Contact Option

Orange

Brown

Ye

llo

w

Vi

olet

Gray

Whit

e

2

TDM

INPUT 

1

12-24V AC/DC

INPUT 

1

CO

M

CO

M

N.

O.

N.

C.

N.

C.

N.

O.

PROGRAM

MODE BUTTON

DISPLAY

ADJUSTMENT

LED DISPLAY KEY

d1 = delay 1

d2 = delay 

d3 = delay d1 to d2

d4 = delay d2 to d1

i1 = input 1 (n.o. / n.c.)

i3 = input 3 (n.o. / n.c.)

i2 = input 2 (n.o. / n.c.)

i4 = input 4 (n.o. / n.c.)

o2 = output 2 (n.o. / n.c.)

o1 = output 1 (n.o. / n.c.)

o1= dry

o1= wet

Output #1

Output #2

INPUT 

4

INPUT 

3

INPUT 

2

CO

M

CO

M

Green

Green

Blue

Wht/Blue

Wht/Red

Wht/Grn

Wht/V

Wht/Gray

Wht/Brown

Page 2

(82A044)  TDMv1017

FIGURE 1—TDM Layout & Wiring Connections

Input Connections

Wht/Brown

Wht/Vio

Wht/Grn

Wht/Red

Wht/Blue

Blue

Green
Green

Wht/Gray

Input Power 12-24V 

(AC or DC)

Switch Input #1

Switch Input #2

Switch Input #3

Switch Input #4

Output Connections

Orange

Brown

Yellow

Violet

White
Gray

Output #2

Output #1

COM

N.O.

N.C.

COM

N.O.

N.C.

Input Actions

Input 1—Sequences Output 1 then Output 2

Input 2—Sequences Output 2 then Output 1

Input 3—Operates Output 1 only

Input 4—Operates Output 2 only

(Factory Setting = Dry Contact)

                             Universal Time Delay Module 

INSTALLATION INSTRUCTIONS

The 

Series

TDM

Commander

7898 Zionsville Road 

 Indianapolis, Indiana 46268

Telephone: (317) 842-2545 

 www.mssedco.com 

 [email protected]

Summary of Contents for TDM

Page 1: ...ns are included Figure 2 Simple Time Delayed Output Figure 3 Electric Lock Door Operator Sequencing Figure 4 Vestibule Door Sequencing Detailed Operating Display functions for the TDM are shown in Figure 5 For additional technical assistance contact us toll free at 1 317 842 2545 Figure 5 TDM Operating Display Function NOTICE These instructions are provided for your convenience Please verify your ...

Page 2: ...044 TDMv1017 FIGURE 1 TDM Layout Wiring Connections Input Connections Wht Brown Wht Vio Wht Grn Wht Red Wht Blue Blue Green Green Wht Gray Input Power 12 24V AC or DC Switch Input 1 Switch Input 2 Switch Input 3 Switch Input 4 Output Connections Orange Brown Yellow Violet White Gray Output 2 Output 1 COM N O N C COM N O N C Input Actions Input 1 Sequences Output 1 then Output 2 Input 2 Sequences O...

Page 3: ...hanged make the change to the d1 setting press the PROGRAM MODE BUTTON once and then wait 30 seconds until the double bars appear again 5 During operation of the unit the display will indicate its operating status Please refer to Figure 5 at the end of this installation manual or Electric Exit Device Wall Switch PUSH TO OPEN WHT RED WHT VIO MS SEDCO TDM Timing Control Module N C Output 1 Input 3 S...

Page 4: ...e door This time is usually set around 0 5 1 second Again adjust the setting and then depress the PROGRAM MODE BUTTON The display should now read d4 Now wait 30 seconds until the double bars appear indicating that the unit is in its normal operating ready mode NOTE d1 should be longer than d3 3 You are now ready to test your installation If any of the time settings need to be changed make the chan...

Page 5: ... is the delay time between the opening of the doors going in the opposite direction Adjust this value in the same manner as before When the PROGRAM MODE BUTTON is depressed i1 will then be displayed Now wait 30 seconds until the double bars appear indicating that the unit is in its normal operating ready mode 3 You are now ready to test your installation If any of the time settings need to be chan...

Page 6: ...o2 Relay Output 2 N O or N C Error flashing The PUSHBUTTON FAULT INDICATOR is a special feature designed to alert the installer if a pushbutton is stuck in the active position or if the wires have shorted If this occurs the display will flash double dots Additionally this could mean that the wiring did not match the programmed parameter In other words the unit may be programmed for use with a norm...

Reviews: