Section 1

General Description

The TDM is a multipurpose timing module that can be 

used for a variety of applications.  Its unique design and 

open architecture allows the TDM to be used in any 

application that requires timing control of up to two 

outputs with up to four inputs.  Common applications 

include: simple time delay, vestibule door sequencing 

(only one device required) and electric lock/automatic 

door operator sequencing.

The four inputs on the TDM allow sequencing or 

independent operation of the two outputs.  Input 1 will 

sequence Outputs 1 then 2.  Input 2 will sequence 

Outputs 2 then 1.  Input 3 will operate Output 1 

independently.  Input 4 will operate Output 2 

independently.

Both outputs on the TDM are fully programmable for "on 

time" duration as well as the delay time between the two 

outputs from 0 to 99 seconds.  

 

 

WARNING: 

 Devices to be controlled by the TDM

 

must be low voltage (12-24V) but can be 

 

inductive loads.  Surge suppressors are standard 

 

on the TDM.

WET/DRY CONTACT OPTION:

The TDM has the option to supply power to Relay Output 

1 contacts.  This is known as having a "Wet" contact 

instead of the conventional "Dry" contact closure.  To use 

output 1 as a "Wet" contact, change the jumper setting 

(see Figure 1).  The voltage supplied to Output 1 will be 

the same as the voltage supplied to the input power wires 

of the TDM.

 

WARNING: 

 Changing jumper settings to enable 

 

the “Wet” Contact option will apply a voltage to 

 

the Output 1 relay contact. Please ensure that 

 

any device connected to this output is capable of 

 

accepting voltage. Failure to do so may result in 

 

damage to the device.

Section 2

Basic Installation

1.  Mount the TDM in desired location.

2.  With power off, make all necessary wiring 

 

connections to the wiring harnesses (Fig. 1).

 

Figure 1:  TDM Layout and Wiring Connections

Detailed wiring and programming instructions for three 

common applications are included.

 

Figure 2:  Simple Time Delayed Output

  Figure 3:  Electric Lock & Door Operator Sequencing

  Figure 4:  Vestibule Door Sequencing

Detailed Operating Display functions for the TDM are 

shown in Figure 5.  For additional technical assistance, 

contact us toll free at 1-317-842-2545.

  Figure 5:  TDM Operating Display Function

 

NOTICE:

  These instructions are provided for your 

 

convenience.  Please verify your installation is in 

 

compliance with all applicable standards upon

 

completing installation of this device.

Section 3

Technical Data

Model....................................... TDM

Input Power.............................. 12-24V AC or DC

Power Consumption................ 2W Maximum

Output Contacts....................... Form C, Rated at 3 Amps

Relay Contact Rating............... 3A:120V AC; 3A:60V DC

Temperature Rating................ -22°F to 158°F 

 

(-30°C to 70°C)

Weight...................................... <0.25 lbs.

Physical Size............................ 4.75"L x 2.125"W x 0.75"H

Section 4

Warranty

MS SEDCO guarantees this product to be free from manufacturing 

defects for 1 year from date of installation.  Unless MS SEDCO is 

notified of the date of installation, the warranty will be in effect for 

1 year from the date of shipment from our factory.  If, during the 

first year, this device fails to operate and has not been tampered 

with or abused, the unit can be returned prepaid to factory and it 

will be repaired free of charge.  After 1 year, the unit will be 

repaired for a nominal service charge.  

This limited warranty is in 

lieu of all other warranties expressed or implied, including any 

implied warranty of merchantability, and no representative or 

person is authorized to assume for MS SEDCO any other liability 

in connection with the sale of our products.  All warranties are 

limited to the duration of this written warranty.  In no event 

shall MS SEDCO be liable for any special, incidental, 

consequential or other damages arising from any claimed 

breach of warranty as to its products or services.

Questions?  Call us toll-free at 1-317-842-2545 or

visit us online at www.mssedco.com.

!

!

!

                             Universal Time Delay Module 

INSTALLATION INSTRUCTIONS

The 

Series

TDM

Commander

7898 Zionsville Road 

 Indianapolis, Indiana 46268

Telephone: (317) 842-2545 

 www.mssedco.com 

 [email protected]

Summary of Contents for TDM

Page 1: ...ns are included Figure 2 Simple Time Delayed Output Figure 3 Electric Lock Door Operator Sequencing Figure 4 Vestibule Door Sequencing Detailed Operating Display functions for the TDM are shown in Figure 5 For additional technical assistance contact us toll free at 1 317 842 2545 Figure 5 TDM Operating Display Function NOTICE These instructions are provided for your convenience Please verify your ...

Page 2: ...044 TDMv1017 FIGURE 1 TDM Layout Wiring Connections Input Connections Wht Brown Wht Vio Wht Grn Wht Red Wht Blue Blue Green Green Wht Gray Input Power 12 24V AC or DC Switch Input 1 Switch Input 2 Switch Input 3 Switch Input 4 Output Connections Orange Brown Yellow Violet White Gray Output 2 Output 1 COM N O N C COM N O N C Input Actions Input 1 Sequences Output 1 then Output 2 Input 2 Sequences O...

Page 3: ...hanged make the change to the d1 setting press the PROGRAM MODE BUTTON once and then wait 30 seconds until the double bars appear again 5 During operation of the unit the display will indicate its operating status Please refer to Figure 5 at the end of this installation manual or Electric Exit Device Wall Switch PUSH TO OPEN WHT RED WHT VIO MS SEDCO TDM Timing Control Module N C Output 1 Input 3 S...

Page 4: ...e door This time is usually set around 0 5 1 second Again adjust the setting and then depress the PROGRAM MODE BUTTON The display should now read d4 Now wait 30 seconds until the double bars appear indicating that the unit is in its normal operating ready mode NOTE d1 should be longer than d3 3 You are now ready to test your installation If any of the time settings need to be changed make the chan...

Page 5: ... is the delay time between the opening of the doors going in the opposite direction Adjust this value in the same manner as before When the PROGRAM MODE BUTTON is depressed i1 will then be displayed Now wait 30 seconds until the double bars appear indicating that the unit is in its normal operating ready mode 3 You are now ready to test your installation If any of the time settings need to be chan...

Page 6: ...o2 Relay Output 2 N O or N C Error flashing The PUSHBUTTON FAULT INDICATOR is a special feature designed to alert the installer if a pushbutton is stuck in the active position or if the wires have shorted If this occurs the display will flash double dots Additionally this could mean that the wiring did not match the programmed parameter In other words the unit may be programmed for use with a norm...