background image

AccuGuard HP2

Modular Safety Beam System 

INSTALLATION INSTRUCTIONS

8701 Castle Park Drive 

 Indianapolis, Indiana 46256

Telephone: (317) 842-2545 

 www.mssedco.com 

 [email protected]

Page 4

(/MANU)HP2v0813

Accu

Gu

ard

 HP

2 WI

RI

NG DIA

GRAM

FIGURE 3

Control Mod

ule

Cont

act Ou

tp

ut

to

Door Controller

PO

WER

(1

2-2

4V A

C/DC)

Non-pola

rity

Tra

nsmit

ter (Blu

e)

L2

L1

N.O.

Wire Shield Wire Shield

L2

L1

Po

w

er

Wire

Shield

Wire

Shield

L2

L1

Po

w

er R

ed

LED

Po

w

er Green LED

R

eceiv

er (Gra

y)

L2

L1

L2 T

ransmitt

er

L1 R

eceiv

er

L2 R

eceiv

er

L1 T

ransmitt

er

Min. Height 20”

Bea

m Ins

ta

lla

tion Guid

e

Ensure the T

ransmitt

er Heads

are installed on opposit

e sides 

of the opening.

Summary of Contents for AccuGuard HP2

Page 1: ...ause the device to malfunction WARNING To avoid beam cross talking mount the Transmitter Beam Heads opposite of each other 4 RECESS MOUNT Push each Beam Head into the 1 2 holes SURFACE MOUNT Attach the surface mount housing with Beam Heads installed at the desired location using the supplied screws ensuring the 1 2 holes are covered Wiring Fig 3 1 Connect Beam Head cables to the Control Module wir...

Page 2: ... Section 5 Technical Data Model AccuGuard HP2 Size Control Module 4 1 2 L x 1 3 4 W x 1 D Recess Mount Beam Heads 1 2 Dia x 5 8 D Surface Mount Beam Head Housings 2 7 8 H x 1 1 2 W x 1 D Cable 2 conductor 16 ft ea Color Coded Blue Transmitter Gray Receiver Detection Method Active Infrared 950nm Detection Range 6 to 32 Feet Power Requirements 12 24V AC or DC No Polarity Requirements Light Resistanc...

Page 3: ...ceivers must be mounted at equal heights above the floor NOTE To accommodate the cables running from the control module to the individual beam heads drill appropriate holes through the door header into the sidelight channel Receiver or Transmitter Receiver or Transmitter SWING The control module may occupy any available space in the door header Receivers or Transmitters Receivers or Transmitters S...

Page 4: ...IRING DIAGRAM FIGURE 3 Control Module Contact Output to Door Controller POWER 12 24V AC DC Non polarity Transmitter Blue L2 L1 N O Wire Shield Wire Shield L2 L1 Power Wire Shield Wire Shield L2 L1 Power Red LED Power Green LED Receiver Gray L2 L1 L2 Transmitter L1 Receiver L2 Receiver L1 Transmitter Min Height 20 Beam Installation Guide Ensure the Transmitter Heads are installed on opposite sides ...