MRS MCharger Easy S Installation And Operating Manual Download Page 30

MCharger_Easy_S_ENG  

Copyright © 2022  

Page 30 

TTechnical data (11 kW / 22 kW)

 

Functions

 

  

Charging Functionality 3.7/7.4 – 11/22kW (1ph-3ph)

 

9

 

Easy Installation

 

9

 

Integrated type 2-socket

 

9

 

Static Status Display (time, kW, kWh)

 

9

 

Acoustic integrated buzzer

 

9

 

RCD Integrated (6mA DC failure)*

 

9

 

SW update CAN (wired)

 

9

 

KfW eligible (Germany only)

 

9

 

Electrical Characteristics

 

  

Charging Mode

 

3

 

Nominal Current (A)

 

16A / 32A 1-3 phase

 

Grid Network System

 

TN - TT

 

Input Voltage (V AC)

 

230 (1ph) / 400 (3ph)

 

Grid Frequency (Hz)

 

50

 

Overvoltage protection IEC 61010-1

 

CAT III

 

IEC 61140 Protection Class

 

I

 

Residual Current Monitoring

 

6mA DC failure  included

 

Mechanical Characteristics

 

  

Dimensions Housing (W x H x D in mm)

 

266 x 441 x 137

 

Weight (kg) including  packaging

 

4,3

 

IP protection  class

 

IP54

 

Mechanical Impact Class

 

IK08

 

Interface Characteristics

 

  

Charging Power

 

11kW / 22kW

 

Output Voltage  (V AC)

 

230 (1ph) / 400 (3ph)

 

Installation Cable

 

 2.5mm² /  

 6mm²

 

Cable feed

 

Top, Bottom, Rear

 

Charging Socket

 

Type 2

 

Status Display 

 

2.4" Color

 

Environmental Characteristics

 

  

Operating Temperature  (°C)

 

-25°C to  +40°C

 

Storage Temperature  (°C)

 

-40°C to  +80°C

 

Permissible max. relative  humidity  (%)

 

95%

 

Maximum Altitude  (m)

 

2000

 

Certifications / 

 

Norms

 

  

CE

 

9

 

RoHS

 

9

 

REACH

 

9

 

WEEE

 

9

 

IEC 61000-6-1 / 61000-6-3

 

9

 

IEC 61851-1

 

9

 

IEC 62196

 

9

 

IEC 62955

 

9

 

Summary of Contents for MCharger Easy S

Page 1: ...MCharger Easy S 11 kW and 22 kW Installation and operating manual...

Page 2: ...IMPORTANT NOTICES Particularly important information is marked in this operating manual as follows DANGER This warning alerts you of possible dangers in handling or operating the wallbox that may lea...

Page 3: ...tools 7 Assembly 8 Connection to the power grid 19 Power grid connection requirements 19 Connecting the power cable 19 Mounting the top cover 22 Operating instructions 23 General 23 Standby mode 23 Ve...

Page 4: ...r approval obligation for the installation or the operation of a wallbox may be mandatory In Germany there is a reporting obligation according to 19 NAV Qualification of personnel for installation and...

Page 5: ...tact the supplier from whom you bought the wallbox immediately Note Check all parts for damage before the assembly Damaged parts may not be installed 1 x Housing with pre assembled lower lid and a cha...

Page 6: ...on the bottom of the MCharger wallbox shows all relevant data Here you will find e g type designation serial number date of manufacture month year as well as the operating parameters of the charging...

Page 7: ...or possible tripping points created by the charging cable x is below an altitude of 2000 m x does not become a tripping hazard due to cables lying around x offers sufficient space for a safe passage b...

Page 8: ...here special attention should be paid to when mounting on the wall If the wallbox is not attached to a wall please follow the instructions in the installation manual of the accessory Preparation Remov...

Page 9: ...be inserted through the middle opening Break out the opening with the screwdriver and hammer then deburr the area with a knife Use the small black rubber grommet for sealing Cable from the bottom The...

Page 10: ...S_ENG Copyright 2022 Page 10 Cable from the top Use the free space to lay a drip shape loop if you want to use the cable entry provided from the top Break out the opening with the pliers and deburr it...

Page 11: ...022 Page 11 Cable from the rear Break out the opening with a screwdriver and a hammer and then deburr it with a knife After entering the cable use the appropriate marking small triangle on the install...

Page 12: ...MCharger_Easy_S_ENG Copyright 2022 Page 12 For the installation from the bottom use the left side mark on the installation rail Draw the mark...

Page 13: ...MCharger_Easy_S_ENG Copyright 2022 Page 13 For a connection cable from the top use the middle marking on the installation rail Draw the mark...

Page 14: ...arger_Easy_S_ENG Copyright 2022 Page 14 For a connection cable from the rear use the right side marking on the installation rail Draw the mark Mark the holes for the installation rail Use a spirit lev...

Page 15: ...suitable screws and dowels Use the screws of max 6 mm Use a cylinder head screw Drill the appropriate holes for the wall bracket Attach the installation rail to the wall with the dowels and screws Ch...

Page 16: ...MCharger_Easy_S_ENG Copyright 2022 Page 16 Attach the wallbox to the installation rail Press the wallbox firmly against the wall Mark the upper holes...

Page 17: ...MCharger_Easy_S_ENG Copyright 2022 Page 17 Insert suitable screws and dowels Remove the wallbox again from the installation rail Drill the pre marked holes Mount the dowels...

Page 18: ...ger_Easy_S_ENG Copyright 2022 Page 18 Insert the connection cable into the wallbox and use the appropriate gray rubber grommet Attach the wallbox to the installation rail Secure the wallbox with two s...

Page 19: ...has the ability to assess the installation steps and to identify any possible dangers On the building side it is necessary to provide RCD type A circuit breaker 30mA AC The wallbox already has an int...

Page 20: ...by shortening the individual wires to the correct length and insulate the individual wires with the stripping pliers The stripping length of the individual wires is 11 13 mm Insert the individual wire...

Page 21: ...MCharger_Easy_S_ENG Copyright 2022 Page 21 Note Check that all wires have a firm fit in the terminal block Note After connection or reconnection the wallbox must be tested according to VDE 0105 100...

Page 22: ...ns the upper cover must be mounted and screwed on Make sure the seal is in the correct fit before placing the cover Insert the cover first at the bottom before it can snap into place at the top of the...

Page 23: ...correctly placed back onto the plug For the rest position the cable must be wound up so that the plug does not lie on the floor Optionally a wall holder for the plug part No 503146 can be ordered Sta...

Page 24: ...llow you to observe the charging process On the left is the time counter it counts the time from the start of the charging process to its completion The charging time is maintained as long as the conn...

Page 25: ...display Charging may be terminated when the battery is fully charged or when the vehicle has stopped charging or paused If the charging process continues after a pause the display switches back to ch...

Page 26: ...fer to the operating instructions of your vehicle and contact your supplier of the wallbox or the vehicle brand dealership Provide the corresponding error IDs from the wallbox and the vehicle 0010 Tem...

Page 27: ...rging cable could not be locked Make sure that the plug of the charging cable has been fully inserted into the charging socket of the wallbox and that it is a compatible charging cable Restart the cha...

Page 28: ...ust be switched off via the circuit breaker and the residual current circuit breaker and secured against being switched on again Then remove the wallbox from the wall or the surface by loosening all t...

Page 29: ...61851 1 2019 12 incl correction 1 x IEC 61851 21 2 2018 x EN IEC 61821 21 2 2021 x IN 55032 2015 x IN 61000 3 11 2000 x IN 61000 3 12 2011 x IN 61000 6 1 2007 x IN 61000 6 3 2007 x DIN EN IEC 63000 2...

Page 30: ...CAT III IEC 61140 Protection Class I Residual Current Monitoring 6mA DC failure included Mechanical Characteristics Dimensions Housing W x H x D in mm 266 x 441 x 137 Weight kg including packaging 4 3...

Page 31: ...MCharger_Easy_S_ENG Copyright 2022 Page 31 D Dimensions...

Page 32: ...fer from the delivered product and do not represent an obligation on the part of the manufacturer The manufacturer assumes no responsibility for any loss and or damage that occurs as a result of any i...

Reviews: