Installation Instructions and Owner’s Manual
Gas Fired Infrared Space Heater
3. SUSPENSION
Heaterhasfourmountingholes,twooneachend,forattaching
rod,chain,orangleironbracketsandshallbesafelyand
adequatelyfixedinpositionindependentofgasandelectricsupply
lines.
4. GAS SUPPLY
Provideadequategassupplyforratedinputofeachheaterusing
AmericanStandardInstallationofgaspipingandgasappliances
inbuilding.ANSIZ223.1a/NFPA54pamphlet,TableC-3shows
capacityofpipeofdifferentdiametersandlengthsincubicfeet
perhournaturalgaswithpressuredropof0.3inches,specific
gravityof0.60.ForliquefiedPetroleumGas(LP)capacityrefer
toFigures3.Onthreadedpipesuseapipecompoundwhichis
resistanttotheactionofallgases.
Ifgaslinesaretobepressuretestedwithcompressedair,
disconnecteachheatertopreventcontroldamageandcap
outlets.Afterreconnectingallheaters,purgegaslinesofair
andcheckallconnectionsforleaksusingsoapsolution.Liquid
dishwashingdetergentisanexcellentleakdetector.
5. PIPING REQUIREMENTS
Allpipinginstalledmustcomplywithlocalcodesandordinances
orwiththeNationalFuelGasCode,ANSIZ223.1(NFPA54),
whichevertakesprecedence.Wheninstallingpiping,thefollowing
requirementsmustbetakenintoconsideration:
• Usenewproperlyreamedblackpipefreefromchips.
• Applyagoodqualitypipecompoundtoallmalethreadsprior
toassembly.IfL.P.gasisthefuel,ensurethatpipecompound
isresistanttoL.P.gas.DONOTUSETEFLON™tape.
• Priortoinstallation,applypipecompoundtoallmalethreads
asshowninFigure1.
USE MODERATE AMOUNT OF PIPE DOPE
LEAVEFIRST2THREADSBARE
Figure 1. Pipe Compound Application
• Malethreadsonpipetobeinstalledintogasvalveshallmeet
therequirementsofFigure2.Threadslongerthanthose
showninthefiguremaycausegasvalvedistortionandmal-
function.
• AsedimenttrapmeetingthetypicalrequirementsofFigure3
shallbeinstalledinthelinetothegasvalve.
• Adedicatedshutoffvalvefortheheatermustbeinstalledin
thegassupplyline.
3/4¾”MAXIMUMTHREADLENGTH
½”BLACKPIPE
GASVALVEBODY
½”MAXIMUMDEPTHOFINSERTS
INTOGASVALVE
NOTE:
1.OnlyUseAPipeCompoundWhichIsResistantToLiquefied
GasesOnL.P.Installations.
2.FittingsShownAreNotIncludedWithHeater.
Figure 3. Typical Piping Installation
6. GAS PRESSURE
Whenahigherthanthemaximumrecommendedgaspressureis
beingmaintainedatthemaingasline,aseparateregulatormust
beinstalledaheadoftheheater.RefertoTable1onpage3for
maximumallowablepressureforstatedheatermodelandgas.
Seeheaterratingplateforminimumgassupplypressure“Forthe
PurposeofInputAdjustment.”
Onamultipleheaterinstallationinmaybepossibletouseone
largecapacityregulatororanindividualregulatorforeachheater.
Nevertheless,itisrecommendedpracticetomaketheentirepipe
systemaloop.
Contactyourlocalrepresentativeorthefactoryforpropergas
pressurereducingdesignstage.
7. ELECTRICAL
NEVERCONNECTPOWERPILEGASVALVEORTHERMOSTATTO
LINEVOLTAGEORATRANSFORMER.
8. THERMOSTAT & LOCATION
Makesurethattheelectricalcharacteristicsofthethermostat
matchthoseoftheheatercontrols.Forbestresultsthermostat
shouldbepositioned5ft.abovefloorwhereaircancirculate
freelyaroundit.
DO NOT MOUNT directly to cold-side wall, in
direct drafts, or directly beneath the infra-red heater.
Ensurethattheselectedthermostatlocationmeetsallofthe
aboverequirements.Refertotheinstructionsthatcomewith
thethermostatforadditionalgeneralinformationandmounting
instructions.
Ifthewallisofstudandwallboardconstruction,thenusethe#6
by1inchsheetmetalscrews,includedwiththethermostat,and
mountthethermostatintheselectedlocation.
Ifwallisbrickormasonry,theappropriateanchorsmustbe
obtainedtoaccommodatethethermostatmountingscrews.Use
thebackplateofthethermostatasatemplatetomarkthehole
location,drillappropriatesizeanchorholes,installtheanchorsand
securelyattachthethermostatusingthemountingscrews.
ConnectthethermostatwirestogasvalveasshowninFigure4.
Figure 2.
Gas valve
connection
requirements
Sedimenttrap