![MRF 12997 Operator'S Manual Download Page 10](http://html1.mh-extra.com/html/mrf/12997/12997_operators-manual_1845854010.webp)
10
5. Disconnect the attachment hydraulic hoses from the
loader’s front auxiliary couplers (A).
a. Rotate the coupler sleeves (B) so the ball (C) is
aligned with the groove (D) to allow the coupler
to disconnect (Some sleeves may not have this
locking mechanism).
b. Grasp and push or pull the sleeves to disconnect
the couplers.
6. Install protective caps on the couplers if they are
provided, and insert the couplers in the tube (E).
WARNING
AVOID INJURY!
Loader attaching plate levers which are operated
manually may have spring tensioning. Firmly grasp
the levers and move the levers slowly.
Installing and Removing
7. Move the loader attaching plate levers (F) to the
unlocked (up) position as shown either manually or
by using the loader controls.
8. Tilt the loader attaching plate forward slightly and
drive the loader backward until the top edge of
the attaching plate clears the top flange (G) of the
attachment mounting frame.