(HTL) setting, the window displays redness and system alarms to attract user’s notice.
(During the initial start-up, a “HTL” alarm is normal operation. After the temperature is
stabilized and the “HTL” alarm stops you can put goods in your freezer);
6. “Ajar” indicator
:
The window displays redness and system alarms to attract if the
door opens for more than 1 minute. After the door is closed, the alarm stops
;
7. Upper sensor: show the upper cabinet temperature.
8. Lower sensor: show the lower cabinet temperature.
9.Door switch
:
To control the evaporation fan movement, the fan stop and compressor
force to start when door open.(So after taking out the goods, please close
the door at once).The system automatically record the time of door open
and duration, Will alarm beyond 1minute.After close the door, Cut off
the compressor force switch(To protect the compressor, Please leave
3minutes for 2times door open).
10.Door heating switch
:
When the surroundings temperature is high, Door body will
drop dew, Please press the door heating switch.
※
11.
When the rechargeable battery existences, when the power source supply
disruption, the screen still lightened, showed the real-time cabinet temperature, recorded the
number of door opening, LTL and HTL alarm. But the ventilator, the lamp and the
refrigeration system does not work. (If the freezer has not been used for long time, the battery
does not have electric quantity, it is normal that the window have no display. When freezer
power source puts through, electrification completes automatically.)
Please close the power switch on the back of the box when the power cut for a
longtime (than three hours), otherwise the electric quantity loses and affects the
battery service life!
(
3
)
Functions Setting
1.
time set:
Press "inspect" key, The Digital-Code window displays Year, month, date, Hour,
minute. Now set the current clock. Temperature window displays current
temperature and the Ten bit of year blinks in clock display window. Press “
▼
” to
change the blinking bit which changes in sequence according “Ten bit of year
One
bit of year
Ten bit of month
One bit of month
Ten bit of day
One bit of
day
Ten bit of hour
One bit of hour
Ten bit of min.
One bit of min.
Am or
PM
Ten bit of year”. All these shows in the format as: “Y
;
D
;
AM
;
PM”. Now
press “
▲
”to add 1 per touch to the blinking bit which will return to the min. after
the max. When the set finishes, press “Enter” activate the setting. Then the number
in time display window stops blinking and the set mark “TIME” disappears to exit
the time setting status. If no keys are pressed within 15 seconds the system exits the