4

3. CONSTRUCTION

Front panel of the meter 

1. 

Case cover

*1- Multi-function electrode support

stand rack (it has been set up under 
bottom of the meter) 

2. keyboard
3. Screen

5. Electrode

4.  Multi-function electrode support stand

Back panel of the meter 

6. 

Measuring electrode socket

7. Reference electrode terminal
9. Temperature electrode socket
10. Fuse
11. Power switch
12. Power socket

6  7  9

10  11  12 

Descriptions of keyboard 

Keyboard

Function

“pH/mV” button 

Press this button to select mV measuring, pH measuring, 

“Std” button
“Slope” button 

For calibration, slope adjusting function

“ENTER” button 

Press this button to confirm the last one operation and then to the next state. 
The other function of the button is in case of mistaken operation in the course 
of calibration, users may switch off the meter, then hold “ENTER” button, 
switch on the meter again, the meter will be in the state of beginning.   

Ÿ

” button 

This button is a increasing value key. Press the button to adjust the value 
larger. Press the button to adjust the temperature value larger manually at the 
pH measurement state; Press the button to adjust the calibration,slope pH 
value larger manually at the calibration,slope adjusting state. 

"

ź

" button 

This button is a reducing value key. Press the button to adjust the value 
smaller. Press the button to adjust the temperature value smaller manually at 
the pH measurement state; Press the button to adjust the calibration,slope pH 
value smaller manually at the calibration,slope adjusting state. 

Descriptions of LCD display

-18.88—Displaying pH measurement and mV measurement value 
88.8 — Displaying temperature value. If the ATC probe connected to the meter, the 

displayed temperature value is the automatic measuring temperature, i.e. the 
temperature of measured solution; if the ATC probe is not connected to the meter, 
the meter will display temperature value which is set by manual.. Press this button 
to set temperature value larger or smaller at the pH measurement state and then 
press “ENTER” button to confirm the temperature value selected. 

PHmV—Being pH and mV measurement value unit 

—Being temperature unit. The   light is flashing, the meter enters adjusting temperature 

state manually. 

Calibration/slope/measurement

ʊ

Displaying corresponding working state.

 

Summary of Contents for INE-PHS-3E

Page 1: ...INE PHS 3E pH Meter Operating Manual PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION Hagavish st Israel 58817 Tel 972 3 5595252 Fax 972 3 5594529 mrc mrclab com MRC 12 16...

Page 2: ...be used until it is up to standard z The warranty of the glass PH electrode is one year The electrode should be replaced in time after one year no matter whether it is used or not since the performan...

Page 3: ...INE PHS 3E 2016 2 CONTENT 1 GENERAL 2 MAIN SPECIFICATIONS AND PERFORMANCE 3 CONSTRUCTION 4 OPERATION INSTRUCTION 5 MAINTENANCE 6 CAUTIONS FOR ELECTRODE OPERATING 7 COMMON PROBLEMS AND SOLVING...

Page 4: ...MANCE 2 1 Range pH mV Temp Measuring range 0 14 00 pH displaying range 2 00 18 00pH 0 1999 mV automatic polar display 0 99 9 Resolution 0 01pH 1mV 0 1 Temp compensation 0 99 9 2 2 Accuracy pH mV Temp...

Page 5: ...alue larger manually at the pH measurement state Press the button to adjust the calibration slope pH value larger manually at the calibration slope adjusting state button This button is a reducing val...

Page 6: ...Enter slope adjusting state Press pH mV button If the temperature electrode is not connected to the meter enter manual adjusting temp state Press or button to adjust temp larger or smaller manually a...

Page 7: ...her calibration that it is not PH 4 00 PH 7 00 and PH 10 01 PH buffer Adjust PH value in the state of calibration to the PH value of the standard solution at this temperature to press Enter button and...

Page 8: ...ion press pH mV button to exit Two point calibration g Prepare two standard buffer solutions Insert the electrode which has been cleaned with distilled water into pH4 00 press Std button once the scre...

Page 9: ...will display Std yes Press Enter button to enter calibration state press any button to exit and return the measuring state Enter the calibrating state the meter recognizes the buffer automatically an...

Page 10: ...on screen 4 3 Electrode potential mV measurement 1 Turn on the meter to enter mV measurement state 2 Clip ion selective electrode or metal electrode and reference electrode on the electrode support s...

Page 11: ...lectrode glass bulb must not be touched to hard substance any damage will make the electrode cease to be effective 3 After measurement put on the electrode sleeve that has little supplementary liquid...

Page 12: ...n liquid interface is the main cause of measuring error 3 when measured solution is PH 10 00 please select buffer solution pH 10 01 4 when measured solution is PH 4 50 please select buffer solution pH...

Page 13: ...ature electrode E 201 PH sealed combination electrode Optional 0 14PH E 201 C PH refillable combination electrode Optional 0 14PH E 201 Z PH cone combination electrode Optional 0 14PH E 201 P PH plate...

Page 14: ...asuring state the instrument can not switch to pH measuring state When the measuring range is over 20 00pH the instrument will show Err first and then switch to mV measuring state 1 Reduce the input s...

Page 15: ...issolve 3 387g GR monopotassium phosphate and 3 533g GR disodium hydrogen phosphate in 1000ml high purity deionized water 3 pH 9 18 solution Dissolve 3 80g GR sodium tetraborate into 1000mL high purit...

Page 16: ...E pH Meter Number Description Quantity 1 INE PHS 3E pH Meter 1 set 2 Power Line universal 1 3 Buffer Solution pH 4 7 10 5 bags for each 4 Fuse BGXP 5 20 0 5A 2 5 Protective Cover small 1 6 PH Combinat...

Page 17: ...n of outer reference solution is always higher than the position of measured solution E When in calibration or measuring in order to avoid cross pollution between different solutions please wash the e...

Reviews: