The failure service 

Some unexpected failures may arise during running. Please pay attention to the running 

status of your 

DW-40FW110

 freezer. If any exceptional case arises, please check and solve it 

according to the following introductions. If the problem is not solved well, please contact our 

service center for details. 

Problem 

Possible Cause   

DW-40FW110

 freezer 

does not operate 

 

Power outage has occurred.

 

The plug is bad or not securely plugged-in.

 

Fuse is blown.

 

Voltage is too low or too high.

Compressor does not 

work 

 

Power in control panel is off.

 

Temperature setting is wrong.

Temperature is higher 

than setting 

 

Frost in inner wall is too thick

 

The door is not closed properly or is opened too frequently.

 

Overfull materials are put into chamber.

 

Ambient temperature is too high.

Too great noise 

 

Freezer is not leveled well.

 

Freezer leans upon the wall.

 

Below are normal operation

 

T

here are some light clashes when the compressor starts up and stops.

 

During rainy and watery season some frost may accumulate on the surfaces of cabinets.

Please clean it with dry rag. 

 

The freezer running, The compressor heat and felt hot.

 

The compressor start or close, the parts may cause the light clash sound.

DO NOT open the door twice within 5 miniatures. This may lead the hot air into the interior 

of freezer and the door may be difficult to open because of a negative pressure due to a sharp 
decrease of temperature of this part air. 

Before call the service engineer, Please clean and disinfect the freezer. 
Condition: Can not shake heavily, strike, prevent drench. 

Environment Temperature: -40

℃~

+55

,  Relative humidity: 10

 

Summary of Contents for DW-40FW110

Page 1: ...Low Temperature Freezer DW 40FW110 Operation Manual PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION Hagavish st Israel 58817 Tel 972 3 5595252 Fax 972 3 5594529 mrc mrclab com MRC 7 16...

Page 2: ...ature Freezer should be trained and authorized The maintenance of equipment should be made by MRC or their s agent If happen the questions which not mentioned in the manual please contact MRC or agent...

Page 3: ...ery low temperature condition for hospital epidemic station blood bank research institute university biological pharmaceutical industry and gene engineering etc The internal temperature in cabinet can...

Page 4: ...us happen to get an electric shock Once the powel line damage Need to change as the special line which provided by the factory or the appointed maintain servic The freezer powei is 220V 50Hz alternati...

Page 5: ...ature Examine parameter Not in the setting status Press show the setting temperature After seconds will show current temperature Press show the return difference temperature After seconds will show cu...

Page 6: ...uicken the process of defrost You can put the 50 water container in the freezer 5 Note Any electric heater metal tool or edge tool CAN NOT be used during defrost operation 6 Then to clean the water wi...

Page 7: ...frequently Overfull materials are put into chamber Ambient temperature is too high Too great noise Freezer is not leveled well Freezer leans upon the wall Below are normal operation There are some li...

Page 8: ...rature 10 25 Valid capacity L 110 Rating vlotage V 220 Rating frequency HZ 50 Input power W 145 Refrigerant R134a Size depth width height mm 549 549 845 The encasement list Item Operation Manual Key D...

Reviews: