11: SAFETY PRECAUTION
Attention
1. Do not use the machine in the high temperature (over 42
0
C) place, or much more
oil and moist place. That will be affecting the machine’s ozone producing rate.
2. Take care to move it. Do not shelter from the gas outside to keep the indoor air
convection
3. Please place the machine in proper location for avoid children improper operation
to cause the Accident
4. Keep gas tube vent hole clean and unfold.
5. When sterilizer is working, please do not use the eyes, breathing to contact the
ozone vent hole directly. Doing so may cause discomfort.
6. When purify the air in the closed room, please ask all the people leave until 30
minutes after the machine stop.
7. Please stop the sterilizer if you feel uncomfortable, strongly stimulate or
headache when sterilizer working.
8. If the indoor air is not circulate, do not use ozone for long time and please open
the window to make the air circulate to avoid the ozone consistence too high.
9. Ozone safety value: 0.01-0.1ppm, as the capacity in the nature.
(
a
)
Please leave the room when purifying the indoor air.
(
b
)
Do not expose Human’s breathing path into ozone’s consistence over 0.1ppm
(
c
)
The ozone half life in the atmosphere is about 40 minutes.
(d) The ozone half life in the water is about 20 minutes.
10. It is normally that the tube became white or yellow.
11. Please put the gas stone at the bottom when sterilizing in the water.
12. For using in process water, the water depth should be at 20cm - 40cm for get a
better result.
Warning
Do keep the control panel and the area around the cleaner clean and dry -- wipe up
solution which spills over the tank brim. Water and high voltage can cause electrical
shock.
Do not operate the cleaner without proper grounding.
Do not remove the grounding prong on the line cord plug.
Do not disassemble the sterilizer -- high voltage inside the cleaner is dangerous.