background image

3, Hagavish st. Israel 58817  Tel: 972 3 5595252, Fax: 972 3 5594529   

  

com

.

mrclab

@

mrc

 

  

  
  
  
  
  

Block Dry Bath

 

DBD-001N 
DBD-002N 

Operation Manual

 

  
  
 

  

  

 

 

Summary of Contents for DBD-001N

Page 1: ...3 Hagavish st Israel 58817 Tel 972 3 5595252 Fax 972 3 5594529 com mrclab mrc Block Dry Bath DBD 001N DBD 002N Operation Manual ...

Page 2: ...r abnormal function of the instrument Note Notes alert you to pertinent facts and conditions Warning If the MRC Digital Dry bath is used in a manner not specified by the manufacturer the protection provided by the unit may be impaired Thank you for selecting MRC for your equipment needs Your MRC Digital Dry bath has been designed with functionality reliability and safety in mind It is your respons...

Page 3: ...tures 3 1 Section 4 Unpacking and installation 4 1 Installation environment Connecting to Power Supply Location Condition Connecting to the main power Section 5 Preparation Work 5 1 Structure Diagram Display Panel Diagram Section 6 Operation 6 1 Examination Before Start Up Start Up Set the Temperature Value Autotuning AT Temperature Offsetting OFFSET Section 7 Troubleshooting 7 1 Error Codes and C...

Page 4: ...ttage heater to provide precise accurate control and rapid heating The Aluminum block chamber ensures an even transfer of heat from the heating element to the block Temperature is easily set using arrow keys while the value is shown on the large display The user calibration function allows for easy calibration to in house standards when required Interchangeable blocks are available to accommodate ...

Page 5: ...void the electric shock the input power line must be reliably grounded The instrument is equipped with the three pin plug that has the third pin the pin connects the ground therefore the plug should be used with the grounded power socket only This is a kind of safety device If the plug cannot be plugged into the power socket b Servicing and Replacement of Parts The operator should not take apart t...

Page 6: ...he instrument should not be placed in a wet or dusty location the openings on this instrument are for ventilation circulation and in order to avoid over heat of the instrument body they should not be blocked or covered When a single set of instrument is used the interval between ventilation opening before and after the instrument and its nearest object should not be less than 25cm Also don t use t...

Page 7: ...s operating in a high temperature state or just finished operation to avoid burns Caution In any of the following cases immediately turn off the power supply withdraw the power plug from the power socket contact the supplier for service Liquid drops into the inside of the instrument The instrument is rained on or water is spilled on it The instrument works abnormally especially if generating an ab...

Page 8: ...tal Microprocessor Controller Heating chamber Molded aluminum alloy chamber Temp control range 5 C Above ambient to 150 C Temperature increment 0 1 C Temp uniformity in working area at 37 C 0 2 C Temp accuracy in working area at 37 C 0 2 C Temperature calibration Yes Operating temperature Ambient to 40 C Block material Aluminum alloy Block type Standard customized type are available Data log optio...

Page 9: ...that all the following parts and accessories are included in the package If not contact your dealer or MRC immediately Item Quantity Main Body 1 Operation Manual 1 Blocks option 1or 2 RS 232 Communication option 1 Installation Environment It should be installed in suitable environment as described below Avoid direct sunlight Room temperature 40 C Relative Humidity RH should be less 80 Altitude sho...

Page 10: ...the motor vibrations should not be placed near this equipment Connecting to Power Supply When connecting power use only the power cord that came with your instrument The power connection procedures are as follows 1 Before connecting the power cord make sure that the main power switch is turned off 2 Plug the other end into a properly grounded and dedicated power outlet nearby Connecting to Main Po...

Page 11: ...apter introduces the structure of the instrument user interface and functions of all buttons and preparation before startup Read the content in the section carefully before startup when using the instrument for the first time 1 Structure Diagram Unit Front 1 Aluminum Alloy Block 2 Housing 3 PID Digital Controller ...

Page 12: ...3 Hagavish st Israel 58817 Tel 972 3 5595252 Fax 972 3 5594529 com mrclab mrc Unit back 4 Power Switch 5 Fuse 5A 6 Power Socket 7 Identification Label ...

Page 13: ...Fax 972 3 5594529 com mrclab mrc 2 Display Panel Diagram 1 Upper Display Present Value PV 2 Lower Display Set Value SV 3 Escape Button Esc 4 Down Button 5 Up Button 6 Scroll Button 7 Auto tuning Indicator 8 Alarm Indicator 9 Heating Indicator Out ...

Page 14: ...reliably grounded Caution If the display of the instrument is abnormal after startup turn off the power source immediately and contact the supplier Start Up Press the power switch and the instrument will power on All indicator lights will be turned on About 3 5 seconds later temperature display window will show the real time temperature All indicator lights will be turned off Set the Temperature V...

Page 15: ...to automatically calculate and set the optimize PID value for your system DO NOT touch the block or the temperature controller during autotuning process Temperature Offsetting OFFSET The temperature shown on the Actual Temperature Display is measured by a temperature sensor inside the unit However this temperature can be different from the temperature of your own thermometer which you may use as a...

Page 16: ...ement Contact MRC for service Repetitive tripping of circuit breaker Controller failure Contact MRC for service Sensor is damaged or in poor contact Contact MRC for service Offset parameter is wrong Check offset parameter Temperature display does not conform to actual temperature Damages in controller Contact MRC for service Too low setting of the temperature controller Increase the temperature se...

Page 17: ...3 Hagavish st Israel 58817 Tel 972 3 5595252 Fax 972 3 5594529 com mrclab mrc Error Codes and Corrective Actions ...

Page 18: ... BK04 25 X Ø12mm 301 01081 05 BK05 25 X Ø13mm 301 01081 06 BK06 12 X Ø15mm 301 01081 07 BK07 16 X Ø15mm 301 01081 08 BK08 12 X Ø16mm 301 01081 09 BK09 16 X Ø16mm 301 01081 10 BK10 12 X Ø19mm 301 01081 11 BK11 16 X Ø19mm 301 01081 12 BK12 9 X Ø20mm 301 01081 13 BK13 9 X Ø26mm 301 01081 14 BK14 4 X Ø28mm 301 01081 15 BK15 4 X Ø40mm 301 01081 16 BK16 49 X 0 5ml tubes 301 01081 17 BK17 25 X 1 5ml tube...

Page 19: ...er supply should be shut off and unplugged The instrument surface should be cleaned with a noncorrosive cleaning agent Inspection Interval Item Daily Weekly Connection status of power cord or plug Damages in power cord or plug Cleanliness of block Cleanliness of main body and accessories Damages in Block Switch Controller Power socket Heating capability check up to 150 Cleaning Product WARNING Nev...

Page 20: ...h or a sponge soaked in water or diluted neutral detergent when necessary Relocation If you need to move the equipment to another place 1 Disconnect the power cord from the power outlet 2 Pack the equipment and its accessories into the original packaging or any other suitable container before moving CAUTION Pay attention to avoid mechanical shock or vibration while moving the instrument Damages ca...

Page 21: ...ement or repair of components parts or equipment under this warranty shall not extend the warranty to either the equipment or to the component part beyond the original warranty period The Technical Services Department must give prior approval for return of any components or equipment Your MRC Sales Office is ready to help with comprehensive site preparation information before your equipment arrive...

Reviews: