background image

35

Compatibility(Max. Conc. 1 mol/L)

Potassium hydroxide solution
Potassium iodate solution
Potassium permanganate solution*
Potassium thiocyanate solution
Silver nitrate solution*
Sodium arsenite solution
Sodium carbonate solution
Sodium chloride solution
Sodium hydroxide solution
Sodium nitrite solution
Sodium thiosulfate solution
Sulfuric acid
Tetra-n-butylammonium hydroxide sol.
Triethanolamine in Acetone*
Zinc sulfate solution

Summary of Contents for BDI-DIG

Page 1: ...User Manual BDI DIG Electronic Bottle Top Dispenser Hagavish st Israel 58817 3 Tel 972 3 5595252 Fax 972 3 5594529 mrc mrclab com MRC 12 22...

Page 2: ...ew 2 3 Parts Description 3 4 Display 8 5 Assembly Instruction 9 6 Operation 15 7 Accessories 20 8 Calibration 26 9 Cleaning and Maintenance 27 10 Trouble Shooting 31 11 Storage 32 12 Warranty 32 13 Li...

Page 3: ...y Reminder s w t i a CAUTION Possible damage to instrument Caution notes indicate any condition or practice which if not strictly observed or remedied could result in damage or destruction of the inst...

Page 4: ...r X 1 Controller X 1 Controller cable USB X 2 User Manual X 1 Bottle Adapter X 5 GL32 GL38 GL28 GL25 S40 Remote Dispensing pipe X 1 Remote Control Handle X 1 Filling valve X 1 Dispensing valve X 1 Fil...

Page 5: ...on 2 1 Specification Volume Range 0 1mL 99 9mL Increment 100 L Precision Dispensing R 10mL 30 L CV 10mL 10 L Stepper R 1mL 6 L CV 1mL 9 L Velocity 16 Stages Battery Capacity 4000mA h Fully charged in...

Page 6: ...3 3 1 BDI DIG No Description Liquid Level Observatin in piston running state Return Valve to adjust the liquid direction of dispensing Dispensing pipe Dispensing pipe cover Dispensing pipe Tip Bottle...

Page 7: ...4 No Description Controller Port Micro USB Main Body lock Air Admission Cap pressure balance 3 2 Remote Control Handle Data Connector Control Knob...

Page 8: ...lling press and hold for filling release it to stop Dispensing press and hold for dispensing release it to stop Setting press and hold 2s into setting interface Pre Filling press and hold 2s for pisto...

Page 9: ...6 Control Panel can be fully adjustable up to an angle of 45 No Description Sensor Holder Assembly Slot...

Page 10: ...7 No Description Power Switch symbol O indicates Off indicates On Remote control handle Port Communication port non function Charging Communication port Main Instrument Port...

Page 11: ...8 4 Display Liquid Volume Unit Battery Indication Indication Arrow piston movement N Dispensing step Max is 50 steps U Aspirating speed 16 speed D Dispensing speed 16 speed...

Page 12: ...g tube into position Step 2 Poke the Dispensing valve slightly with the tool as shows in the picture ensure the balls in the valve can move slightly Step 3 Connect the dispensing pipe tail end with th...

Page 13: ...ease confirm compatibility prior to use Refer to chapter Limitations and Step 4 Poke the filling valve slightly with the tool as shows in the picture ensure the balls in the valve can move slightly St...

Page 14: ...11 Step 6 Choose a suitable bottle adapter then connect it with BDI DIG main body Step 7 Turn bottle adapter to fasten main body and bottle...

Page 15: ...hat the adapter is fastened prior to each use For perfect working please do not move or touch main Instrument during operation to avoid physical damage to your BDI DIG Step 8 Use USB cable to connect...

Page 16: ...13...

Page 17: ...14 Step 9 Turn Return Valve to direction If liquid is needed to be emptied from the barrel turn Return Valve to direction BDI DIG basic system was assembled...

Page 18: ...seconds to let air out leaving the piston at the bottom of the barrel finally 6 2 Dispensing Step 1 Press and hold Setting button about 2s to active the parameter setting Step 2 Press Setting button...

Page 19: ...nd hold Dispensing button to dispense arbitrary target liquid CAUTION The value of liquid volume will not recording or display target liquid volume change 6 3 Stepper Step 1 Press and hold Setting but...

Page 20: ...range is 1 to 16 Step 3 Press Setting button to liquid volume parameter setting the total volume of the target liquid Parameter N setting BDI DIG one times max dispensing volume is 10mL Parameter N Th...

Page 21: ...ct the actual use please running several times aspirating and dispensing If this solution not works please contact with the dealer or manufacturer 6 4 Liquid Emptying If liquid is needed to be emptied...

Page 22: ...19 had been emptying Step 3 Turn Return Valve to direction Emptying operation was completed...

Page 23: ...20 7 Accessories 7 1 Remote Control Handle The Control Handle is fully map the operation of Control Panel easy to operate over a long distance MAX Length 90 cm...

Page 24: ...21 7 2 Assemble Sensor Holder Step 1 Fasten the Holder into place Step 2 Press black button of the clamp and release until reaching the appropriate altitude...

Page 25: ...22...

Page 26: ...23 Assembly diagram 7 3 Remote Dispensing pipe Remote Dispensing pipe can effectively extend the dispensing distance MAX Length 1 5m...

Page 27: ...e are made of FEP Please confirm compatibility prior to use Refer to chapter Limitations and Compatibility manufacturer Step 1 Connect the dispensing pipe tail end with the Dispensing valve Step 2 loc...

Page 28: ...25 Step 3 Follow the figure to assemble the adapter and remote Dispensing pipe...

Page 29: ...up at least five times Hardware needed Electronic balance with readability of 0 01 mg Distilled water X86 or X64 architectured PC with pre loaded Windows XP Vista 7 8 10 operating system Software need...

Page 30: ...he barrel the operation reference liquid emptying Step 1 Turn Return Valve to direction long press Pre filling button make the piston stop at the barrel bottom Step 2 Press Filling and Dispensing butt...

Page 31: ...elivery to service personnel and inform details of last liquid handling 9 33Filling and Dispensing valve Replacement Use the Installation tools to disassemble the old valve replace the new valve to th...

Page 32: ...29 Disassemble Dispensing valve Disassemble Filling valve...

Page 33: ...30...

Page 34: ...o refill refilling sucks back into the dispensing tip Dispensing valve is contaminated or dispensing tip damaged Bubbles in the instrument Dispensing volume is less than the volume displayed Filling p...

Page 35: ...lectronic pipettes are covered by one year warranty against defects in workmanship and materials Please contact us or your nearest distributor ANY WARRANTY WILL HOWEVER BE DEEMED AS VOID DUE TO NORMAL...

Page 36: ...dling liquids like hydrofluoric acid The instrument would be clogged or damaged by solid particles in turbid liquid like activated carbon The plastic parts of your BDI DIG would be in swelling conditi...

Page 37: ...solution Bromide bromate solution Cerium IV sulfate solution EDTA solution Hydrochloric acid Hydrochloric acid in Acetone Iodine solution Iodide Iodate solution Iron II sulfate solution Nitric acid Ox...

Page 38: ...lution Potassium thiocyanate solution Silver nitrate solution Sodium arsenite solution Sodium carbonate solution Sodium chloride solution Sodium hydroxide solution Sodium nitrite solution Sodium thios...