5 Mounting
28
BA5789879-01 EN
Opening the device
Prepare for mounting the device as follows:
1. In order that the protective cover can be removed, pull out signal pin (5)
and screw off the signal pin cap (6) using 2 open-ended wrenches,
wrench size 12 and 32.
2. Unscrew the 2 screws (1), wrench size 10, on the stand plate, and the
screw, wrench size 10, on the opposite side of the protective cover.
3. Lift off protective cover (4).
Mounting the device
The dimensions and connection data for mounting are specified in the ap-
pendix.
1. Place the mounting seal ring (delivered as an option) under the device,
see Dimensions with standard protective cover [
53].
2. Mount the device onto the counter flange on the transformer / on-load tap-
changer by inserting 6 screws M12 or 1/2" (not supplied) through the drill
holes in the device flange.
Figure 6: Mounting the device
1 Mounting seal ring Ø 200 x Ø
178.5 x 4.25 mm [Ø 7.87" x Ø7.03"
x 0.17"]
2 6 screws M12 or 1/2"