Installation and Operating Instructions
4
Installation to be performed by a
qualified and licensed electrician.
Insure that power is not supplied to
the field wiring during installation. Turn off power at
breaker panel.
Insulation must be a minimum of
3
" away from all sides of the fixture assembly.
1.
Determine the placement of the light.
Do not install the fixture assembly
(light) where direct contact with steam or water emission
could occur. Do not install the light in a location where it
could become submerged.
2.
The light requires a 4-
1
⁄
4
" diameter hole for mounting.
3.
Provide electrical service (
120
VAC) with flexible cable
only. Pass cable through ceiling opening and wire fixture
in accordance with NEC and local electrical code. A stan-
dard single pole wall switch must be installed to turn the
light on and off. One wall switch can be used to control
multiple lights.
DO NOT install the wall switch in the
steam room. The switch must be installed in a location and
manner described in the NEC and local electric codes.
Do not use a dimmer switch to
control the ChromaSteam Lights
4.
Connect the supply wires per the wiring diagram. Use
suitable wire nuts (not included) to insulate and secure
the connection.
5.
Connect copper ground wire from wiring box to ground
wire from electrical service using a wire nut to secure
the connection.
6.
Use the support adjustment screw shown to provide
support for the housing on the inside surface of the
ceiling when installed.
7.
With the clips folded into the fixture as shown in figure
1
insert the wired housing into the ceiling junction box
first as shown in figure
2
.
8.
Hold fixture up against the ceiling and push clips through
housing slot. To lock clip in place push flat portion
against the side of the fixture using a flat head
screwdriver (Fig.
3
).
3"
MIN. CLEARANCE ALL AROUND
AND BETWEEN FIXTURE AND INSULATION
FIXTURE MUST BE INSTALLED IN A DRY LOCATION
Retainer Clip
Pulled In During
Installation
Support
Adjustment Screw
3"
3"
3"
Retainer clips
locked in place
to secure fixture
1
⁄
2
"– 1
1
⁄
8
"
Ceiling Thickness
STEAM ROOM
WARNING
!
WARNING
!
WARNING
!
CAUTION
!
WARNING
!
CAUTION
!
CHROMA
Field Supplied
Wiring
120 VAC
L
N
G
Wall Switch
(Field Supplied)
Wiring Box
bl
ac
k
w
h
it
e
gr
ou
n
d
Wiring Diagram
GENERAL INSTALLATION
with iTEMPO
®
, eTEMPO & Stand Alone
See page
3
for installation instructions when installed with an eTempo/Plus control.
Not required for Tempo, Tempo/Plus, eTempo or stand alone installations
Figure 1
Figure 2
Figure 3