mr
.
steam
®
Electric Towel Warmers
Installation and Operating Instructions
________________________________________________________________
AVAILABLE DIGITAL PROGRAMMABLE TIMER
Installation: To The Installer
1. Read the operating instructions provided with the timer.
2. Disconnect power supply prior to installation to prevent
electrical shock.
3. Damage to the contacts caused by short circuiting will
void the warranty.
4. Wire in accordance with National Electrical and Local
Code requirements. Be sure all connections are secure.
Double check all twist-on wire connectors.
AVAILABLE DECORATIVE FACEPLATE FOR TIMER:
Polished Chrome 103872D-PC
Polished Nickel
103872D-PN
Brushed Nickel
103872D-BN
Oil Rubbed Bronze 103872D-ORB
8
ELECTRICAL SPECIFICATIONS
Field Wired Models: W500, W542, W634
Electrical Connections
TO PREVENT SHOCK HAZARD, BE CERTAIN THAT ELECTRICITY
IS TURNED OFF AT THE MAIN PANEL BEFORE ANY WIRING IS DONE.
All wiring must conform to National Electrical and Local Codes.
GENERAL:
The Towel Warmer requires 120VAC, 60 Hz power supply.
Specific amperage needed is listed in the Towel Warmer Specifications Chart on page 2 of
PUR
103852.
A. Electrical connections should be made as prescribed by the National Electric and Local Codes. The unit should be field wired
using 14 AWG min 90°C-rated copper wire. All models are to be protected by a separate 15 amp circuit breaker or equal.
B. Make connections between Towel Warmer and house wiring using approved connections to comply with National Electrical
Local Codes. LINE (black), NEUTRAL (white), and GROUND.
C. Install the Towel Warmer according to the specific instructions for each model.
TO PREVENT SHOCK HAZARD, NO BARE WIRE OR
WIRE STRANDS SHOULD BE VISIBLE AFTER MAKING CONNECTIONS.
Electric Towel Warmer
Thermal Fuse
Thermostat Element
Heating Element
Wiring Box
Field Wiring
L
N
GRND
L
N
GRND
Field Installed Wall Switch or
Mr. Steam Digital Programmable Timer
PN: 103588DIG
Indicator Light
X
X
X
5. Mount timer into wall box using supplied screws.
6. If timer does not operate, check that the timer’s black
wire is connected to
hot line and not the load. If necessary, reverse connec-
tions to red and black wires
7. When the indicator light on the towel warmer is illumi-
nated, the towel warmer is energized.
!
WARNING
!
WARNING