background image

MS AromaFlo

®

A

Table of Contents

Box Contents

. . . . . . . . . . . . . . . .

2

Assembly and Installation

General Installation . . . . . . . . . . . . .

3

Installation of Hoses . . . . . . . . . . . . .

4

Assembly Diagram . . . . . . . . . . . . . . . . . .

5

Electrical Wiring . . . . . . . . . . . . . . .

6

Start-up

Initial Priming of AromaSteam System . . .

7

Filling the Pressure Hose . . . . . . . . . .

7

Adjusting amount of oil delivery

. . . . 7

Troubleshooting

. . . . . . . . . . . . . .

8

Technical Information

. . . . . . . . . .

8

NOTE:

It is strongly recommended that this warning sign (supplied)

be posted in a conspicuous location near the steam room.

Do not use with water soluble

fragrance or fragrance containing emulsifiers or aldehy-
des. AromaSteam system damage may result. Mr.Steam
oils are approved for operation with this system.

The use of any oils other than

Mr.Steam oils may introduce excessive concentration of
oil into the steam room, resulting in a health hazard.

Vapors may cause drowsiness and

dizziness. Keep out of the reach of children. In case of
contact with eyes, rinse immediately with plenty of
water and seek medical advice. If swallowed, rinse mouth
with water (only if the person is conscious), seek medical
advice immediately and show this container or label.

Highly Flammable. Keep away

from sources of ignition– No smoking. Keep container
tightly closed & in a well-ventilated place. This material
& its container must be disposed of as hazardous waste.

Not for use in acrylic or fiberglass

rooms.

Material Safety Data Sheet (MSDS) available upon request

WARNING

!

WARNING

!

WARNING

!

WARNING

!

signals a situation where minor injury or product
damage may occur if you do not follow instructions.

IMPORTANT NOTE:

This highlights information that is especially relevant
to a problem-free installation.

IMPORTANT NOTE:

As you follow these instructions, you will notice warning and caution symbols. This blocked information is important for the safe and efficient
installation and operation of this AromaSteam. These are two types of potential hazards that may occur during this installation and operation:

states a hazard which may cause serious injury
or death if precautions are not followed.

AromaSteam

(for illustrative purposes only)

This room is equipped with an aromatic oil dispensing system.

Leave the room immediately if you have any adverse or
allergic reactions, including difficulty breathing or eye, nasal,
throat, or skin irritation and seek medical attention.

mr

.

steam

®

43-20 34th Street , Long Island City NY 11101

1 800 76 STEAM www.mrsteam.com

PUR 100405

WARNING

!

Motor Operated

Pumps 24VW

mr

.

steam

®

aromasteam

Operation and Installation Instructions

_________________________________________________

WARNING

!

CAUTION

!

mr

.

steam

®

Sussman-Automatic Corp

®

[email protected]
www.mrsteam.com

43-20 34th Street
Long Island City, NY 11101
Tel: 1-800-76 STEAM
Fax: 718-472-3256

9410 S. La Cienega Blvd.
Inglewood CA 90301
1-800 -72 STEAM
Fax: 310-216-2944

WARNING

!

PUR

100402 - 6/08

AromaSteam IOM 08:AromaSteam 05.IOM  6/16/08  10:24 AM  Page 1

Summary of Contents for eTempo Plus

Page 1: ...or fiberglass rooms Material Safety Data Sheet MSDS available upon request WARNING WARNING WARNING WARNING signals a situation where minor injury or product damage may occur if you do not follow instr...

Page 2: ...ARNING WARNING signals a situation where minor injury or product dam age may occur if you do not follow instructions IMPORTANT NOTE THIS HIGHLIGHTS INFORMATION THAT IS ESPECIALLY RELEVANT TO A PROBLEM...

Page 3: ...tem is 1 5 ft If this minimum distance of 1 5 ft cannot be maintained install a radiation plate or heat insulation between the heat source and AromaSteam system Ambient temperature at and around the A...

Page 4: ...iner and discard 3 Insert the suction hose with the open end from below through the hole in the container cap see Fig 3 4 Insert the filter into the scent container so that the filter rests on the bot...

Page 5: ...am Head 90 T Atomizer Nozzle Pressure Hose Suction Hose Scent Container AromaSteam Demand Button Mounting Bracket AromaSteam System Steam Line Pump Line Cord 120V grounded receptacle required Tempo Te...

Page 6: ...on the request cable NOTE When using generators hooked up in tandem the AromaSteam steam system should be connected to the contactor on the primary generator The atomizing nozzle should be connected...

Page 7: ...e generator is steaming the pump will inject oil into the steam line at preset time intervals 3 If the generator is not steaming no oil will be pumped Note After the generator has been turned off the...

Page 8: ...hose or the pump head To eliminate air bubbles see Priming Pump 4 Check valves for contamination Clean valves if necessary 5 Check filter in container for contamination Rinse filter under clean water...