mr
.
steam
®
Broadway Collection Towel Warmers
Installation, Operation & Maintenance Instructions
_______________________________________________________________
6
ELECTRICAL CONNECTIONS
TO PREVENT SHOCK HAZARD,
THE ELECTRICITY MUST BE TURNED OFF AT THE
MAIN PANEL BEFORE ANY WIRING IS ATTEMPTED.
The towel warmer is an electric device.
It must be installed by a licensed electrician in accordance
with the National Electrical Code (NEC) and local code.
Installation of a wall switch or timer to
turn the towel warmer on and off is required.
NOTE:
When the towel warmer is energized (ON), the
indicator light on the towel warmer will illuminate.
NOTE:
The Towel Warmer wires are color coded: BLACK
for LINE, WHITE for NEUTRAL, GREEN/YELLOW for
EQUIPMENT GROUND.
IMPORTANT NOTE:
Some towel warmers have a ground
lug inside the wiring box. Secure the ground wire from the
house wiring to the ground lug using the provided nut.
• Install Towel Warmers in upright position only. Locate
with wiring box and pilot light on bottom as shown on
pages 4 & 5. Failure to install properly may result in
overheating and a hazardous condition.
• All wiring must conform to National Electrical Code
(NEC) and local code.
• Do Not alter or modify any MrSteam products. Doing
so may result in an inoperable or hazardous installation
and will void the warranty.
!
WARNING
!
WARNING
!
WARNING
!
CAUTION
Wiring Box
Set Screw(s)
Wiring Box
Wiring Box
Field
Wires
Wiring Box
Escutcheon
Wiring Box
Escutcheon
BX Connector
Lock Nut
BX Cable*
(or greenfield)
Wires from
wiring box
1. Assemble the BX cable connector to
the wiring box escutcheon as shown.
NOTE:
NM (non-metallic) cable,
if permitted by National and
Local Codes, may be used
instead of BX cable
2. Secure wiring box escutcheon to the
wall with screws provided.
(Use longer screws as required by
construction conditions.)
3. Connect wiring per instructions.
4. Slide the wiring box into the wiring
box escutcheon and tighten the set
screw firmly. Secure the upper and
lower brackets per the instructions
on page 5.
INSTALLATION OF A BROADWAY COLLECTION TOWEL WARMER
WITH A JUNCTION BOX.
A wall plate is required to complete this installation.
Available wall plates: Polished Chrome 104093PC
Field
Wires
Wires from
Wiring Box
Wiring Box
Wiring
Box Set
Screw
Wiring
Box
Wiring Box
Escutcheon
Wall
Plate
Screws
1. Assemble the bushing
to the wall plate and
wiring box escutcheon
as shown.
2. Secure the assembly
to the junction box
using the screws
provided with the
wall plate.
3. Connect wires
per instructions
4. Slide the wiring box into
the wiring box escutcheon
and tighten the set screw
firmly. Secure the upper
and lower brackets per the
instructions on page 5.