background image

11

Operating Instructions and Owner’s Manual

Mr. Heater | Forced Air Propane Construction Heater

Mr. Heater • Forced Air Propane Construction Heater • Model #MH125FAV

REF. #

ITEM #

DESCRIPTION

QTY.

1

1671

Grille Assembly

1

2

1551

Motor Assembly

1

3

7898

Fan, 8"

1

4

1998

Cylinder, Outer Shell Assembly

1

5

7095

Handle

1

6

7094

Clip Handle Mounting

2

7

7433

Fitting, Male Elbow

1

8

1083

Spark Plug, 1/8 Gap

1

9

2003

Control, High Limit Switch Assy.

1

10

3036

Bracket, Thermocouple

1

11

3787

Spacer, Thermocouple

1

12

2002

Orifice, LP Assembly

1

13

2001

Cylinder, Middle Assembly

1

14

3037

Nut, Spark Plug

3

15

2004

Flame Holder Assembly

1

16

3038

Nut, Orifice Mounting

1

17

1668

Fuel Tube Assembly

1

18

6654

Thermocouple

1

19

3044

Bracket Ignition Relay

1

20

6641

Terminal Board

1

21

6065

Spacer, Steel

1

22

1811

Relay Assembly

1

23

3275

Ignitor, Hi-Lo 801 Mini

1

24

6079

Spacer, PC Standoff Nylon

3

25

6265

Fitting, Elbow Street

2

26

7897

Ball Valve, Variable Rate

1

REF. #

ITEM #

DESCRIPTION

QTY.

27

7405

Fitting, Female Connector

1

28

6227

Snap Bushing, 1 1/4 Nylon

1

29

7158

Snap Bushing, 3/4 Nylon

1

30

6133

Fitting, Coupling

1

31

6127

Fitting, Male Connector

1

32

7285

Valve, Thermoelectric

1

33

6223

Bushing, Strain Relief

1

34

1036

Power Cord

1

35

6433

POL Excess Flow 1/4 MPT

1

36

6257

Regulator, 28" W.C.

1

37

6152

Hose Assembly, LP

2

38

4019

Bottom Control Box

1

39

7843

Washer, Flat

1

40

2005

Control Box Assembly

1

*

6374

Label, Electrical Ground

1

*

6373

Label, Fan

1

*

8784

Label, Operating Instructions

1

*

7709

Label, Ignition/Fuel

1

*

8371

Label, BTU Rating

2

*

7503

Label, Wiring

1

*

M8510

Label, Model

1

*

70056

Manual, Operating Instructions

1

*

8203

Label, Hang Tag, LP

1

*

7704

Label, Warning

1

* Item not shown on exploded view

Summary of Contents for Heatstar MH85FAV

Page 1: ...lowed exactly a fire or explo sion may result causing property damage personal injury or loss of life WARNING Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appli ance WHAT TO DO IF YOU SMELL GAS Do not try to light appliance Extinguish an...

Page 2: ... DAMAGE FROM HAZARDS OF FIRE EXPLOSION BURN ASPHYXIATION CARBON MONOX IDE POISONING AND OR ELECTRICAL SHOCK ONLY PERSONS WHO CAN UNDERSTAND AND FOLLOW THE INSTRUCTIONS SHOULD USE OR SERVICE THIS HEATER IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL LABELS ETC CONTACT THE MANUFACTURER WARNING FIRE BURN INHALATION AND EXPLOSION HAZARD KEEP SOLID COMBUSTIBLES SUCH AS BUIL...

Page 3: ...ducts enter the heated space Even though this heater operates very close to 100 percent combustion efficiency it still produces small amounts of carbon monoxide Carbon monoxide called CO is toxic We can tolerate small amounts but not a lot CO can build up in a heated space and failure to provide adequate ventilation could result in death The symptoms of inadequate ventilation are headache dizzines...

Page 4: ...e is cut replace with hose assembly listed on parts list before using heater 8 For indoor use only Area must be well ventilated Figure 1 also see Operating Precautions 9 If at any time gas odor is detected IMMEDIATELY DISCONTINUE operation until the source of gas has been located and corrected Read enclosed Odor fade and Propane Sheet for additional information about detecting propane leaks 10 Ins...

Page 5: ...e person and the firefighters check for escaped gas Have them air out the building and area before you return Properly trained service people must repair any leaks check for further leakages and then relight the appliance for you ODOR FADING NO ODOR DETECTED Some people cannot smell well Some people cannot smell the odor of the man made chemical added to propane LP or natural gas You must determin...

Page 6: ...tting If the O ring is cut scuffed or otherwise damaged replace it with part number 6681 3 Turn off the gas at the LP gas supply cylinder s when the heater is not in use 4 When the heater is to be stored indoors the connection between the LP gas supply cylinder s and the heater must be disconnected and the cylinder s removed from the heater and stored out of doors and in accordance with Chapter 5 ...

Page 7: ...expected at the bottom of the chart 2 Move straight up to time of operation desired left side of chart 3 Read the cylinder size required All heaters should have full cylinders good air circulation no frost on cylinders MAXIMUM OPERATING TIME HOURS MAXIMUM OPERATING TIME HOURS MAXIMUM OPERATING TIME HOURS 55 000 BTU HR 16 1 kW 85 000 BTU HR 33 4 kW 125 000 BTU HR 49 1 kW AIR TEMPERATURE o F o C AIR...

Page 8: ...unction Block 1806 Orange 6 152mm Relay Thermocouple Junction Block MH55FAV MH85FAV MH125FAV WIRING CHART WIRING DIAGRAMS CONNECTION DIAGRAM MOTOR IGNITOR B SCHEMATIC DIAGRAM HIGH LIMIT SWITCH THERMOCOUPLE SPARK PLUG MOTOR IGNITOR RELAY GAS HIGH LIMIT SWITCH SPARK PLUG THERMOCOUPLE R or Y R or Y I1 I2 B or O B B W B RELAY B W B W G LINE CORD 115V 60HZ VALVE I1 I2 COLOR CODE LEGEND BLACK BLUE WHITE...

Page 9: ...1654 Motor Grille Assy 1 20 3676 Brkt Motor Mounting 1 21 1652 Motor Assy 1 22 6086 Fan 7 1 23 1729 Outer Cylinder Assy 1 24 7094 Clip Handle Mounting 2 REF ITEM DESCRIPTION QTY 25 7095 Handle 1 26 6225 Snap Bushing 5 8 1 27 6226 Universal Bushing 1 28 6224 Snap Bushing 1 2 1 29 6654 Thermocouple 13 Lg w J B 1 30 1082 Spark Plug 1 31 3037 Spark Plug Nut 2 32 6121 Ftg Male Elbow 1 33 3038 Orifice N...

Page 10: ... 1 17 3275 Spark Ignition 115V 1 18 1668 Fuel Tube Assembly 1 19 6133 Fitting Coupling 1 20 3787 Spacer TC Bracket 1 21 6127 Fitting Male Connector 1 22 7285 TE Valve 1 23 7404 Ball Valve Variable Rate 1 REF ITEM DESCRIPTION QTY 24 7405 Fitting Female Connector 1 25 3690 Control Panel Assembly 1 26 6223 Strain Relief Bushing 1 27 1036 Power Cord 1 28 6152 Hose Assembly 1 29 6257 Regulator 28 W C 1...

Page 11: ...41 Terminal Board 1 21 6065 Spacer Steel 1 22 1811 Relay Assembly 1 23 3275 Ignitor Hi Lo 801 Mini 1 24 6079 Spacer PC Standoff Nylon 3 25 6265 Fitting Elbow Street 2 26 7897 Ball Valve Variable Rate 1 REF ITEM DESCRIPTION QTY 27 7405 Fitting Female Connector 1 28 6227 Snap Bushing 1 1 4 Nylon 1 29 7158 Snap Bushing 3 4 Nylon 1 30 6133 Fitting Coupling 1 31 6127 Fitting Male Connector 1 32 7285 Va...

Page 12: ...4135 Include your name address and telephone number and include details concerning the claim Also supply us with the purchase date and the name and address of the dealer from whom you purchased our product The foregoing is the full extent of the responsibility of the Company There are no other warranties express or implied Specifically there is no warranty of fitness for a particular purpose and t...