Code NFPA 54/ ANSI Z223.1, Section 5.3, Air for Com-
bustion and Ventilation for required size of ventilation
grills or ducts.

*IMPORTANT:

 Do not provide openings for inlet or

outlet into attic.  If attic has a thermostat-controlled
power vent, heated air entering the attic will activate
the power vent.

IMPORTANT:

 Vent-free heaters add moisture to the

air.  Although this is beneficial, installing heater in
rooms without enough ventilation air may cause
mildew to form from too much moisture. See Fresh
Air for Combustion and Ventilation, pages 3 through
5.

INSTALLATION

NOTICE:

 This heater is intended for the use as supple-

mental heat.  Use this heater along with your primary
heating system.  Do not install this heater as your
primary heat source.  If you have a central heating
system, you may run system’s circulating blower while
using heater.  This will help circulate the heat throughout
the house. In the event of a power outage, you can use
this heater as your primary heat source for the duration
of the outage.

WARNING:

 A qualified service person must install

heater.  Follow all local codes.

CHECK GAS TYPE

Use only 

LP-gas.

 If your gas supply is not 

LP-gas

, do

not install heater.  Call dealer where you bought heater
for proper type heater.

FOR PERMANENT INSTALLATION:

Before installing heater, make sure you have the items
listed below:

Piping (check local codes)

Sealant (resistant to LP_Gas)

Equipment shutoff valve*

Ground joint union

Test gauge connection*

Sediment trap

Tee joint

Pipe wrench

*A CSA/AGA certified equipment shutoff valve with 1/8”
NPT tap is an acceptable alternative to test gauge
connection.  Purchase a CSA/AGA certified equipment
shutoff valve from your dealer. See Accessories, page 17.

This heater may also be installed with the hose and
regulator assembly included with heater.

LOCATING HEATER

This heater is designed to be mounted on the wall.

For convenience and efficiency, install the heater:

Where there is easy access for operation,
inspection, and service.

In the coldest part of the room.

CAUTION:

 If you install the heater in a home garage:

Heater pilot and burner must be at least 18
inches above floor.

Locate heater where moving vehicle will not hit it.

CAUTION:

 This heater creates warm air currents. These

currents move heat to wall surfaces next to heater.  In-
stalling heater next to vinyl or cloth wall covering or oper-
ating heater where impurities (such as tobacco smoke,
aromatic candles, cleaning fluids, oil or kerosene lamps,
etc.) are present in the air may discolor walls.

WARNING:

 Never install the heater:

In a bathroom.

In a bedroom

In a recreational vehicle.

Where curtains, furniture, clothing, or other
flammable objects are less than 36 inches from
the front, top, or sides of the heater.

As a fireplace insert

In high-traffic areas

In windy or drafty areas

WARNING:

 Heater must be mounted to maintain the

minimum clearances shown in Figure 4. If possible,
provide greater clearances from the floor, ceiling, and
joining walls.

Figure 4

FASTENING HEATER TO WALL

Mounting Bracket

The mounting bracket in located on the back panel of
heater (see figure 5). It has been taped there for shipping.
Remove mounting bracket from back panel.

Left
Side

Right
Side

36” min. from
ceiling

6” Min from
adjoining
walls

2” min. to top surface of carpet,
tile or other combustible material

Floor

Summary of Contents for Blue Flame MHVFB10LP

Page 1: ... a qualified installer service agency or the gas supplier WARNING This is an unvented gas fired heater It uses air oxygen from the room in which it is installed Provi sions for adequate combustion and ventilation air must be provided Refer to FreshAir for Combustion and Ventila tion section on page 3 of this manual WARNING Improper installation adjustment alteration service or maintenance can caus...

Page 2: ...or anemia those under the influence of alcohol and those at high altitudes Propane LP Gas Propoane LP gas is odorless An odor making agent is added to propane LP gas The odor helps you detect a Propane LP gas leak However the odor added to propane LP gas may be present even though no odor exists Make certain you read and understand all warnings Keep this manual for reference It is your guide to sa...

Page 3: ...ir The information on pages 3 through 5 will help you classify your space and provide adequate ventilation Unusually Tight Construction If your home meets all of the three following criteria you must provide additional fresh air See Ventilation Air from Outdoors page 5 Unusually tight construction is defined as construction where a Walls and ceilings exposed to the outside atmo sphere have a conti...

Page 4: ...f an adjoining room If the extra space provides an unconfined space remove door to adjoining room or add ventila tion grills between the rooms See Ventilation Air From Inside Building Fig 2 B Vent room directly to the outdoors See Ventilation Air From Outdoors Fig 3 C Install a lower Btu hr heater if lower Btu hr size makes room unconfined If actual Btu hr used is less than the maximum Btu hr the ...

Page 5: ...off valve with 1 8 NPT tap is an acceptable alternative to test gauge connection Purchase a CSA AGA certified equipment shutoff valve from your dealer SeeAccessories page 17 This heater may also be installed with the hose and regulator assembly included with heater LOCATING HEATER This heater is designed to be mounted on the wall For convenience and efficiency install the heater Where there is eas...

Page 6: ... bracket to wall studs 1 Drill holes at marked locations using 9 64 drill bit 2 Place mounting bracket onto wall Line up holes on each end of bracket with hole drilled in wall 3 Insert mounting screws through bracket and into wall studs 4 Tighten screws until mounting bracket is firmly fastened to wall studs Attaching to Wall using Anchor For attaching mounting bracket to hollow walls wall areas b...

Page 7: ...pressure to between 11 and 14 inches of water If you do not reduce incoming gas pressure heater regulator damage could occur Install external regulator with the vent pointing down as shown in Figure 12 Pointing the vent down protects it from freezing rain or sleet CAUTION Use only new black iron or steel pipe Internally tinned copper tubing may be used in certain areas Check your local codes Use p...

Page 8: ...OTE CYLINDER MAXIMUM SIZE 20 LBS This Heater may be used in a Recreational Enclosure or Temporary Construction Work Enclosure with a Remote Refillable Propane Cylinder ONLY when the Cylinder is Located Outdoors and the Heater is Used with Mr Heater Hose assembly supplied DANGER NEVER bring a refillable propane cylinder indoors A fire or explosion can occur causing property damage serious injury or...

Page 9: ...to heater is on 3 Push in gas control knob and slightly turn clockwise to the OFF position see figure 16 Note Knob cannot be turned from PILOT to OFF unless knob is pushed in slightly Do not force 4 Wait five 5 minutes Then smell for gas including near the floor If you smell gas STOP Follow B in the safety information above If you do not smell gas go to the next step 5 Push in gas control know sli...

Page 10: ...ct pilot flame pattern is not touching thermocouple This will cause the thermocouple to cool When the thermo couple cools the heater will shut down If pilot flame pattern is incorrect as shown in Figure 22 Turn heater off see To Turn OFF Gas to Appli ance page 11 for non thermostat models See Troubleshooting pages 14 and 15 Figure 22 BURNER FLAME PATTERN Figure 23 show a correct burner flame patte...

Page 11: ... should also be followed 1 Shut off the unit including the pilot Allow the unit to cool for at least thirty minutes 2 Inspect burner and pilot for dust and dirt 3 Blow air through the port slots and holes in the burner A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly To clean the pilot assembly find the small pilot air inlet hole about two inches from where the pilot f...

Page 12: ...d 1 Burner orifice is clogged 2 Burner orifice diameter to small 3 Inlet gas pressure is too low 1 Manifold pressure is too low 2 Burner orifice is clogged When Piezo ignitor knob is turned there is no spark at pilot ODS pilot lights but flame goes out when control knob is released When Piezo ignitor knob is turned there is a spark at the ODS pilot but no ignition Burner does not light after ODS p...

Page 13: ... line have gas line checked by local gas company 3 Observe minimum installation clearances see Figure 4 page6 4 Clean burner orifice see Cleaning and Maintenance on page 13 or replace burner orifice 1 Turn heater off when using furniture polish wax carpet cleaner or similar products White powder residue forming within burner box or on adjacent walls or furniture 1 Heater burning vapors from paint ...

Page 14: ...nerco Group Inc s 800 on the back of this manual TECHNICAL SERVICE You may have further questions about installation operation or troubleshooting if so contact Enerco Group Inc s 800 on the back of this manual ACCESSORIES Purchase these heater accessories from your local dealer If they can not supply these accessories contact your nearest Parts Central or call Enerco Group Inc s 800 for informatio...

Page 15: ...Electrode 20 1 70654 Burner Mounting Bracket Right 1 20 2 70599 Burner Mounting Bracket Left 1 22 1 70328 Heat Shield Top 1 22 2 70329 Heat Shield Right 1 22 3 70331 Heat Shield Back 1 23 70663 Regulator Mounting Bracket 1 24 70665 Floor mount feet 2 26 70332 Grill guard 1 27 2 70364 Orifice 10 BF 1 33 1 70335 Heat Shield Left 1 42 70337 Control Valve Knob 1 43 70589 1 4 SAE Flare x 3 8 MPT 1 44 2...

Page 16: ... original factory replacement parts Failure to use original factory parts voids this warranty The heater MUST be installed by a qualified installer in accordance with all local codes and instructions furnished with the unit This warranty does not apply to parts that are not in original condition because of normal wear and tear of parts that fail or become damaged as a result of misuse accidents la...

Reviews: