Mr. Heater, Inc. | Kerosene Forced Air Heater

Operating Instructions and Owner’s Manual

3.  Slide the large washer, then wheel onto the axle next to the 

cotter pin.

4.  Slide the spacer onto the axle next to the wheel.
5.  Slide the partially assembled axle through the wheel support 

frame.

6.  Slide the spacer onto the axle next to the wheel support.
7.  Slide the wheel then large washer onto the axle and hold in 

place with the remaining cotter pin.

8.  Install the caps over the larger washers to finish the wheel 

assembly.

PREPARING FOR OPERATION

1.  Check the heater for possible shipping damage. If any is 

found, 

immediately

 contact the manufacturer at  

800-251-0001.

2.  Follow all of the “Precautions”. 
3.  Fill the fuel tank with clean kerosene. In extremely cold 

weather, condensation may develop in the tank and it is 
recommended that a tablespoon of de-icer be added for 
each gallon (4 liters) of fuel in the tank. When filling the 
heater, use at least 2 gallons (8 liters) of fuel. Be sure heater 
is level and do not overfill. Use a funnel or can with a long fill 
spout.

IMpORTANT: Before filling fuel tank the first time or after ex-
tended storage periods, drain the fuel tank of any moisture 
or condensation.

4.  Locate heater at a safe distance from combustible materials. 

Models MH50KR & MH75KTR are not suitable for use on 
wood floors or other combustible materials. When used, the 
heater should rest on suitable insulating material at least 1 
inch thick and extending 3 ft. or more beyond the heater in 
all directions.

HEATER START up

1. 

MH50KR:

 Plug the heater into a grounded 115V, 60 Hz, 1 Ø 

outlet.

MH75KTR, MH125KTR, MH175KTR & MH210KTR:

 

Turn 

thermostat to lowest setting, make sure “On/Off” switch 

is “Off”. Plug the heater into a grounded 115V, 60 Hz, 1 Ø 

outlet. Turn thermostat to highest setting. Start heater by 
pushing toggle switch to “On” position (light signifies switch 
is in “ON” position). Adjust thermostat to desired setting. 
Heater will cycle on/off as heat is required.
EXTENSION CORD REQUIREMENTS: Up to 100’ (30.5m) use 
16 awg. conductor. 101’ - 200’ (30.5 - 61.0m) use 14 awg. 
conductor.

For all models: 

•  In cold weather (below 10° F), starting may be improved by 

holding a finger over the vent hole of the pump adjustment 
screw cap until the heater starts. 

•  This unit is equipped with an interrupt circuit. The reset is 

integrated into the “On/Off” switch. If the unit does not 
start, toggle the switch to “Off”, wait 5 min. and toggle 
the switch to “On”.

HEATER SHuT DOWN

1. 

MH50KR: 

Unplug heater from power source.

 

MH75KTR, MH125KTR, MH175KTR & MH210KTR: 

Push 

“On/Off” switch to “Off” position. For extended shutdown, 
unplug heater from power source.

RESTART AFTER SAFETY SHuTDOWN

 (

MH50KR, MH75KTR, 

MH125KTR, MH175KTR & MH210KTR) See page 7

MH50KR - Unplug unit. Wait 5 minutes. Plug back in.
MH75KTR, MH125KTR, MH175KTR & MH210KTR - Toggle switch to 

“OFF” position, wait 5 minutes. Restart.

MAINTENANCE AND STORAGE

WARNING.

 To prevent personal injury, unplug the heater from the 

wall outlet before servicing. 
For maximum efficiency and trouble-free service, make the 
following periodic maintenance, cleaning and inspections.

AdjUSTING PUMP PRESSURE 

Due to varying fuel viscosities and normal component wear the 
pump pressure on this heater may need to be adjusted.  

ADJUSTMENT PROCEDURE:

Fill fuel tank.

1. 

Start heater.

2. 

Locate the fuel pressure adjustment screw (ref. #29) in the 

3. 

exploded parts drawing.  The pressure adjustment screw 
is located at the rear of the heater, in the air filter housing 
cover (approx.2” from the left side and 1” from the top). 
Remove and discard the rubber cap (ref. #4) to expose the 
screw.
Using a flat bladed screw driver, turn the pump pressure 

4. 

adjustment screw clockwise to increase pump pressure and/
or counter-clockwise to decrease pump pressure.  Base pump 
pressures can be found in the specifications chart on page 3 
of the “Operating Instructions and Owners’ Manual”.
For best results, the nose cone in the combustion chamber 

5. 

should be cherry red with no dark spots and the flame 
should not extend beyond the nose cone.

IMPROPER PRESSURE ADJUSTMENT

problem: 

   Heater does not have a strong consistent flame.

 

 

Heater smokes and spits raw fuel.

 

 

Nose cone does not get cherry red.

Adjustment:

 Pump pressure is too low.  

 

 

Turn adjustment screw clockwise to increase pump  

 

 

pressure.

problem:

 

Flame extends beyond the end of the heater.

Adjustment:

 Pump pressure is too high. 

 

 

Turn adjustment screw counter clockwise to  

 

 

decrease pump pressure.

DAILY SCHEDULE

1.  GENERAL. Make general visual inspection of heater for loose 

or damaged parts. Check nuts and bolts to insure against 
looseness caused by vibration or rough handling. Damaged 
parts should be repaired or replaced before using heater 
again. Check heater operation to be sure it is operating 
normally (See “Servicing” section for description of normal 
operation).

2.  FILTERS. Dirty air or fuel filters will cause an imbalance in 

the air-fuel mixture. The best indication that this condition 
exists is an increase in odors or difficulty getting your heater 
to ignite. This heater should never be operated without the 
filters in place. If required, clean filters as described under 
“500 Hours” and “Annual Schedules”.

Summary of Contents for 125KTR

Page 1: ...ed portable heater It uses air oxygen from the area in which it is used Adequate combustion and ventilation air must be provided Refer to page 3 KEROSENE FORCED AIR HEATER UL 733 CSA CAN3 B140 9 3 03...

Page 2: ...D USE OR SERVICE THIS HEATER IF YOU NEED ASSISTANCE OR HEATER INFORMATION SUCH AS AN INSTRUCTIONS MANUAL LABELS ETC CONTACT THE MANUFACTURER WARNING FIRE BURN INHALATION AND EXPLOSION HAZARD KEEP SOLI...

Page 3: ...ns and instructions and of the hazards involved SAFETY PRECAUTIONS 1 Recommended for use with No 1 K kerosene fuel Factory tested for use with No 2 K kerosene No 1 or No 2 Diesel No 1 or No 2 fuel oil...

Page 4: ...ater from power source MH75KTR MH125KTR MH175KTR MH210KTR Push On Off switch to Off position For extended shutdown unplug heater from power source RESTART AFTER SAFETY SHUTDOWN MH50KR MH75KTR MH125KTR...

Page 5: ...solid object to remove contaminates Compressed air or liquids should not be used to clean this filter Reinstall cleaned filter in filter body in the same position as it was when removed If the filter...

Page 6: ...wing troubleshooting guide for unit status and corrective action if necessary SYMPTOM TROUBLE SHOOTING High limit switch Open Circuit 1 Make sure heater is cooled off toggle switch to OFF position wai...

Page 7: ...SET MOTOR CAPACITOR CIRCUIT BOARD 18AWG YELL 18AWG YELL 18AWG RED 18AWG RED 18AWG WHT 18AWG BLK 18AWG GRN 18AWG PURPLE 18AWG PINK 18AWG PINK 1 2 3 4 5 6 18AWG PURPLE THERMOSTAT 18AWG BLUE 7 8 ELECTR0...

Page 8: ...ert 19 26898 26898 26898 26898 Receptacle 110V 20 22104 22104 22104 22104 AC Receptacle Cover 21 26833 26833 26833 26833 26833 Air Pump Cylinder 22 21810 21810 21810 21810 21810 Outlet Housing 23 2181...

Page 9: ...ions and Owner s Manual Kerosene Forced Air Heater Model MH50KR MH75KTR MH125KTR MH175KTR MH210KTR 1 2 3 4 5 6 7 9 10 1 1 13 14 15 16 17 18 19 20 21 24 25 Filter Kit 26 53 28 29 30 31 32 34 35 36 37 3...

Page 10: ...dealer or direct from the factory FOR INFORMATION REGARDING SERVICE Please call Toll Free 800 251 0001 www mrheater com Our office hours are 8 30 AM 5 00 PM EST Monday through Friday Please include t...

Reviews: