PAGE 40 — DCA-300SSK III — PARTS AND OPERATION MANUAL (FEMA) — REV. #1 (05/07/03)
Engine Shutdown
To shutdown the generator use the following procedure:
1. Place both the
MAIN
,
GFCI
and
LOAD
circuit breakers
(Figure 54) to the "
OFF
position".
Figure 54. Main, Aux. and GFCI
Circuit Breakers (OFF)
2. Place the engine speed switch in the “
LOW
” position
(Figure 55).
Figure 55. Engine Speed Switch (High)
3. Let the engine cool by running it for 3-5 minutes with no
load applied.
4. Place the Auto-Off/ Reset Manual switch (Figure 56) to the
OFF/Reset position
Figure 56. Off/Manual Auto Switch
2. Verify that the
all
status LED on the MPEC display are
"
OFF
" (not lit).
3. Remove all loads from the generator.
Emergency Shutdown Procedure
1.
PUSH
inward the
RED
emergency stop button located
on the
engine operating panel
(Figure 57) to turn off
the generator in the event of an emergency.
Figure 57. Emergency Stop Button
NEVER
stop the engine suddenly except
in an emergency.
DO NOT
use the
emergency stop switch a as method of
shutting down the generator. This switch is
ONLY
to be used in the event of an
emergency.
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION
:
DCA-300SSK III — GENERATOR SHUT-DOWN PROCEDURE (MANUAL)
NOTE
To disengage the emergency
stop function, pull the
emergency stop button outward
to its original position. This will
allow the generator to operate
normally.
Remember the
generator will not start if the emergency stop button is
engaged.
Summary of Contents for DCA-300SSK III Series
Page 2: ...PAGE 2 DCA 300SSK III PARTS AND OPERATION MANUAL FEMA REV 1 05 07 03 ...
Page 7: ...DCA 300SSK III PARTS AND OPERATION MANUAL FEMA REV 1 05 07 03 PAGE 7 NOTE PAGE ...
Page 41: ...DCA 300SSK III PARTS AND OPERATION MANUAL FEMA REV 1 05 07 03 PAGE 41 NOTE PAGE ...
Page 53: ...DCA 300SSK III PARTS AND OPERATION MANUAL FEMA REV 1 05 07 03 PAGE 53 NOTE PAGE ...
Page 103: ...DCA 300SSK III PARTS AND OPERATION MANUAL FEMA REV 1 05 07 03 PAGE 103 NOTE PAGE ...