background image

Part

 

name

1

2

3

4

5

6

7

8

9

10 1

1

1

2

1

3

1

2

3

4

5

6

7

8

9

10

11

12

13

LCD

Φ

Mounting hole

Load

 

status

red

Chrge

 

status

green

Input PV1

Battery terminal

Dry contact terminal

RS485 Communication

Attention

!

Input solar panel matrix power 

Grounding operation.

Input PV2

Forward or Increase

Backward

 

or

 

Reduce

Setting or Enter

Load ON/OFF or Ese

1. the MPPT solar controller has the function of simultaneous input of two solar panels. In theory, the two solar panels can input
 different open circuit voltages and different power, and both can work normally. however, in order to balance the overcurrent 
 inside the controller, it is strongly recommended that the solar panels of the same specification be used in both ways, which is 

 beneficial to the service life and efficiency of the controller. 

2.

The controller has a limited power function, and when the total power of the two solar panels or each input solar panel exceeds

   the rated power, the controller will limit the charging power to the rated power, so it is strongly recommended not to connect to 
  solar panels that exceed the rated power.

Connect the wire

1.For the specification of the connecting cable, refer to the installation instructions. 
2.When the connection cable between the solar panel or controller and the battery is relatively far away, the use of a thicker cable 
can reduce the voltage drop and increase charging efficiency

Installation and connection

Warning: the danger of explosion! 
Never install the controller and thebattery in the same airtight space! Nor should it be installed in an airtight battery where gas 
may accumulate the place. 

Warning: high pressure is dangerous! 

PV  arrays may generate high open-circuit voltages. Disconnect circuit breakers or safety before wiring, and be careful 
during wiring. 

Note

: when installing the controller, make sure that enough air flows through the heat sink of the controller, and there is at least 

150mm space above and below the controller to ensure natural convection and heat dissipation. 

If installed. In a closed box, it is necessary to ensure reliable heat dissipation through the box.

M4860ADS is a common positive design controller. The 

 electrode of solar panel and battery can be grounded at the 

same time, or any positive terminal can be grounded. In practical application, the terminal can also be grounded. 
It is not necessary to ground separately, but the shell must be grounded during installation, which can prevent external 

electromagnetic interference and shell electrification from causing damage to the human body.

positive

Temperature compensation

Note

: when the remote temperature sensor is not connected, the controller will charge or discharge the battery at 25 

 by 

default, without temperature compensation.

Modification of battery charging parameters

Note: when selecting the default battery type, the charging parameters cannot be modified. If you want to modify the charging 

parameters, the battery type must select "Custom".

Overheat protection

When the internal temperature of the controller is more than 80 

, the controller stops working. When the temperature drops 

to 60 

, the controller resumes charging. If the overtemperature protection is repeated three times, the charge will be stopped

completely. which needs to be reset manually or can be recharged the next day.

14

14

Temperature sensor

Summary of Contents for M4860ADS

Page 1: ...ure that the battery works in the best state and greatly prolong the service life of the battery 8 It has full automatic control such as overcharge overdischarge overload protection anti reverse prote...

Page 2: ...rtight battery where gas may accumulate the place Warning high pressure is dangerous PV arrays may generate high open circuit voltages Disconnect circuit breakers or safety before wiring and be carefu...

Page 3: ...hort circuit in the whole process otherwise it may cause serious safety accidents Connection cable the connection cable between the controller and the battery is as short as possible which can effecti...

Page 4: ...tal stripes rolling up dynamically Load ON Load OFF Press K1 or K2 to cycle forward or backward to browse the current working parameters or set working status Battery voltage PV1 voltage PV2 voltage C...

Page 5: ...rface Browse and press K1 or K2 to cycle to the parameter interface you want to set Short press K3 button SET display SET font flashes to indicate that you can start to change the current parameter pr...

Page 6: ...lashes press K1 or K2 key to change the number of minutes in a cycle 0 59 5 Press the K3 key again the SET and M icons stop flashing the load time is set and save the settings Dual period real time co...

Page 7: ...the battery voltage here otherwise The controller will report an error and the controller will not work Battery voltage Automatic identification Set night detection voltage The night detection voltage...

Page 8: ...or code is displayed and the buzzer alarms synchronously and the alarm continues until the error is corrected Press K4 to exit the wrong generation interface return to the main interface and turn off...

Page 9: ...3 7V Equalization charge 14 6V no 14 8V Boost voltage 0 2V Boost charge 14 4V 14 3V 14 7V 14 15V Float charge 13 5V 13 8V 13 5V 13 14V Boost charge recovery 13 2V Low voltage recovery load output 12 5...