![mpec SA380-IT User Manual Download Page 72](http://html1.mh-extra.com/html/mpec/sa380-it/sa380-it_user-manual_1843052072.webp)
Auxiliary Power Output
5 V
1 W
+/- 10 %
+/- 10 %
Volt-Free Contact Output
N.O
SPST
Volt-Free Contact Withstand Voltage
+/- 100 V Pk
Min.
Volt-Free Contact On Resistance
8
Max.
Volt-Free Contact Off Resistance
1 M
Min.
Volt-Free Contact Current Handling
150 mA
AC or DC RMS
Volt-Free Contact Mimimum Load
100
required to assure surge immunity
Serial Data Output
EIA RS485
Wireless Modem (SIM Factory Fitted)
SMA (Female)
GSM 2G GPRS
Ethernet*
RJ45
10/100 Mbs
Auto MDIX
*Ethernet is ordinarily for use as a monitoring port only. Ethernet port requires additional surge protection when used as a
permanent connection.
Supported Protocols
MPEC RailDaq
Efficient Data Communications
Ethernet
GSM
RS485
TCP/IP Port 7777
Port 7777
TCP/IP
112,800 bps
Network Rail MIMOSA
Verbose Data Communications
Ethernet
GSM
TCP/IP Port 80
TCP/IP Port 80
SNTP
Time Synchronization
Ethernet
GSM
UDP Port 123
Port 123
UDP
HTTP
Configuration and Live Data
Ethernet
GSM
TCP/IP Port 80
Port 80
TCP/IP
Environmental
EMC Emissions & Immunity
EN50121-4
Surge Immunity: Monitored Circuits & Earth
EN61000-4-5
4kV
Voltage Withstand
EN50124-1
EN61010-1
Climatic Class
EN50125-3
T1 In cubicle
Ambient Operating Temperature
-25 °C to +70 °C
Storage Temperature
-40 °C to +85 °C
Humidity
5 % to 100 %
Condensing
Vibration
2.3 m/s
2
3 - axis'
Impact Protection
IK06
Ingress Protection
IP52
Flammability Rating
UL94 V0
ESD
Not protected
Observe ESD handling precautions