MPB SERIES TX200 TRANSMITTING FLOWMETER 

Instruction Manual 

 

 

CONTENTS 

 
1  

INTRODUCTION  

2  

TECHNICAL  

3  

INSTALLATION 

 

 

3.1     Electrical connections 

4  

OPERATION  

 

4.1  

Transmitter board 

 

4.2 

Applying Power to the Transmitter for the  

                        first time 

 

 

4.3 

Calibrating the Transmitter 

 

4.4 

Setting Flow Rate Alarms 

 

4.5 

Extended output range 

– NAMUR 43 

 

4.6 

Special Output Current Capabilities 

 

4.7 

Power On Delay 

 

4.8 

ID/Serial Number 

 

4.9 

Setting Flow Rates and Flow Rate Units 

 

4.10 

Flow Volume and Flow Volume Alarm 

 

4.11 

Flowmeter Runtime Values 

 

4.12 

RS485 Full-Duplex Communications 

 

4.13 

Alarm Relay Configuration 

5  

MAINTENANCE  

TROUBLE SHOOTING 

WARRANTY 

 

ILLUSTRATIONS 
MPVA 2050 Overall dimensions      

 

 

 

 

  

MPVA 2051 Overall dimensions with wall mounting bracket  

 

 
1   

 INTRODUCTION 

 

The TX200 Flowmeter is for use with many types of gases.  Parts in contact with gases are of a 316 (A4) 
stainless steel construction.  The enclosure for the pointer and interface board is produced from an 
aluminium billet with a hard anodised coating.  
 
All versions have an analogue pointier and graduated scale display.  This can be a percentage display 
(0

–100%), or a calibrated scale to suit customer requirements.   

 
The TX200 Flowmeter can be fitted with a rotary encoder.  This gives 4-20mA output that reflects the 
specific flow rate of the flowmeter.  

 

Summary of Contents for TX200 Series

Page 1: ... Full Duplex Communications 4 13 Alarm Relay Configuration 5 MAINTENANCE 6 TROUBLE SHOOTING 7 WARRANTY 8 ILLUSTRATIONS MPVA 2050 Overall dimensions MPVA 2051 Overall dimensions with wall mounting bracket 1 INTRODUCTION The TX200 Flowmeter is for use with many types of gases Parts in contact with gases are of a 316 A4 stainless steel construction The enclosure for the pointer and interface board is...

Page 2: ...ss Temperature 150ºC Viton seals Min Process Temperature 5ºC Ingress Protection of Enclosure IP67 Performance Measuring Span 10 1 Measuring Accuracy 5 Full scale analogue scale Electrical Power Supply 7 12 Vdc Cable Gland Entry M12 Outputs 4 20 mA High and Low flow Alarms Factory set Normally Closed but can be supplied Normally Open Mechanical Flow Tube Body Material 316L Stainless Steel Float Bod...

Page 3: ...e instrument to avoid the accumulation of particles around the measuring float The TX200 flowmeter can be supplied with wall mounting brackets see fig 2 Note The inlet needle valve is designed to control the flow to the inlet of the measuring tube This is not a shut off valve Note Remove all packing including any internal transportation aids from inside the enclosure Do Not install a flowmeter int...

Page 4: ...be recalibrated to give a more linear output This can be done at the factory or onsite with the aid of bespoke software from MPB 4 2 Applying Power to the Transmitter for the first time Connect power to the board as detailed in section 3 1 Both LED s on the transmitter board will start to flash quickly This indicates the meter needs calibrating 4 3 Calibrating the Transmitter To set the 20mA upper...

Page 5: ... diagnostics is enabled a message will also be transmitted The corresponding LED will illuminate when the upper or lower flow rate alarm point is reached To disable the upper alarm move the pointer to the minimum flow rate press the upper button for 2 seconds then release The upper LED will flash twice if successful To disable the lower alarm move the pointer to the maximum flow position press the...

Page 6: ... report alarms in loop and the output current will show 3 6mA for lower alarm active 21 0mA for upper alarm active II Select report not cal in loop and if the flowmeter min max flow rates are not calibrated then the current loop will be 23 0mA 4 7 Power On Delay A value from 0 to 250 seconds default 3 can be set which will inhibit the loop output until the delay period from power on has elapsed Th...

Page 7: ...ays High and Low are configured as Normally Closed NC at the Factory These can be set to Normally open NO This should be stated at time of ordering or returned to the factory to be set 5 MAINTENANCE Minimal maintenance is required for TX200 Flowmeter It may be required to clean the internal flow tube to remove any chemical deposits that have adhered to the flow tube Remove the TX200 Flowmeter from...

Page 8: ...re is free from defects in workmanship and materials Corrosion or other decomposition by chemical action is specifically excluded as a defect covered hereunder MPB Industries Ltd s warranty does not cover 1 Damage caused by use of the items for purposes other than those for which they were designed 2 Damage caused by unauthorised attachments or modifications 3 Products subject to any abuse misuse ...

Page 9: ...MPBTB 130 Iss 1 Page 9 of 10 Figure 1 ...

Page 10: ...MPBTB 130 Iss 1 Page 10 of 10 Figure 2 ...

Reviews: