background image

F50S

 Service Parts and Maintenance 

MASTER PNEUMATIC  -  DETROIT, INC.   

6701 -18 Mile Rd

. | 

Sterling Heights, MI 48314   |   Phone: (586) 254-1000  |  Fax: (586) 254-6055  |  Email: [email protected] 

JAA 10-10-03 

REV 10-03-05 

(ECN 4075) 

STU-2004 

Installation Procedures 

Replacement Parts & Kits 

BF50S Section View 

(Manual Drain) 

KEY 

DESCRIPTION 

BF50S-2V 

F50S-2V 

Head 

130-15S-1/4 

130-15S-1/4 

O-Ring, Bowl 

406-23V 

406-23V 

Element Kit  

KA130-27PE5V  KA130-27PE5V 

Metal Bowl with Manual Drain 

ABF130-22SV 

ABF130-22SV 

Manual Drain Kit  

K60F-11M 

A130-19V 

Not 

Shown

 

Plastic Bowl with Manual Drain 

A10F-130V 

A10F-130V 

THANK YOU! 

 

You have just purchased a quality Filter from Master Pneumatic. 

 

With care in it’s installation and maintenance, you can expect it to have a long and 

economical service life.  Before you go any further, please take a few  

minutes to look over this information, then save it for future reference and  

for the useful service information it contains.   

INSTALLATION: 

Depressurize and lockout air pressure.  Install the filter as near as possible to the device it is to serve, following the arrow direction on the filter 
head for air flow.  Filters should be installed upstream of any regulators, lubricators, or valves in the air line. 
 
 

ADJUSTMENTS: 
Manual Drain: 

For Metal Bowls: Turn knob (B) clockwise to drain filter.  For Plastic bowls: Push drain knob to drain filter. 

 
 

MAINTENANCE: 

To clean or service the unit, depressurize and lockout air pressure.  Remove bowl assembly by turning counterclockwise.  To remove the element 
(#3), insert a screwdriver in the slot located at the bottom of stem (A).  Turn stem (A) counterclockwise until it is free of head (#1).  Replace with 
new element and reassemble to finger tight.  Do not clean filter elements, they must be replaced.  Sintered bronze elements may be cleaned by 
soaking several hours in a suitable solvent, then blowing them out in reverse direction to normal flow with compressed air or steam.  For manual 
drain models, periodically drain to discharge accumulated liquids.  
 
 
Plastic bowls may be cleaned with soap and water.  Replace plastic bowls with metal if any signs of crazing or cracking are observed.

 

FLOW

 