INSTALLATION
14
INSTALLATION
(Cont.)
Chemical Connections
NOTE:
Consult a qualified chemical supplier
for your chemical needs.
Refer to Fig. 10
1. A chemical signal terminal block is
supplied for chemical dispensing
equipment.
2. The terminal block is located below
the cycle timer on the left side of the
hinged control panel.
Refer to Fig. 11
3. The detergent signal is limited
to a maximum load of 1 Amp
Signal voltage is 230VAC.
4. The Rinse aid/Sanitizer
signal is limited to a max-
imum load of 1 Amp.
Signal voltage is 230VAC.
Rinse aid/Sanitizer
Signal Connection Point
1 Amp Max load/230VAC
Common Return
Figure 10
Chemical Dispenser
Signal
Terminal Block
Figure 11
Chemical Signal
Connection Points
Detergent Signal Connection Point
1 Amp Max Load/230VAC