Installation
Electrical Connection - Single or Three Phase
WARNING:
Electrocution hazard when working on energized circuits.
Disconnect power at the main breaker or service disconnect
switch, then lock out and tag it to indicate that work is being
performed on the circuit.
1.
Position the machine near its final location.
2.
Remove top-mounted control cabinet cover.
3.
Route conduit to terminal block at rear of control cabinet. Be sure to leave a 6 foot / 2
meter service loop.
4.
Refer to the MACHINE ELECTRICAL CONNECTION DATA PLATE located adjacent
to the input terminal block.
Volt: 208-240
Amp: 46-41
Ph: 3 Hz: 60
Machine Electrical Connection Data Plate
Mod: DH6000T
Series: VHR
Minium Supply Conductor Ampacity
For supply connection, use copper connectors in accordance
with local electrical code. Rated Minimum 90°C (194°F).
60/60
AMPS
60/60
AMPS
Maximum Supply Overcurrent
Protection Device
Overcurrent Protection Device: Time Delay or Inverse Time
Circuit Breaker
2
18"
[457]
12 18"
[308]
LINE IN
3 PHASE CONNECTION
L1
L2
L3
GRD
Fig. 8
LINE IN
1 PHASE CONNECTION
L1
L2
NOT
USED
GRD
8