Moxa VPort 364 Industrial Video Encoder
Getting Started
3-13
STEP 3:
Once the screws are fixed in the wall, insert the four screw heads through the large parts of the keyhole-shaped
apertures, and then slide the VPort 364 downwards, as indicated in the figure. Tighten the four screws for
added stability.
Wiring Requirements
ATTENTION
Be sure to disconnect the power cord before installing and/or wiring your Moxa VPort 364.
Calculate the maximum possible current in each power wire and common wire. Observe all electrical codes
dictating the maximum current allowable for each wire size.
If the current goes above the maximum ratings, the wiring could overheat, causing serious damage to your
equipment.
You should also pay attention to the following:
•
Use separate paths to route wiring for power and devices. If power wiring and device wiring paths must
cross make sure the wires are perpendicular at the intersection point.
NOTE: Do not run signal or communications wiring and power wiring in the same wire conduit. To avoid
interference, wires with different signal characteristics should be routed separately.
•
You can use the type of signal transmitted through a wire to determine which wires should be kept separate.
The rule of thumb is that wiring that shares similar electrical characteristics can be bundled together.
•
Keep input wiring and output wiring separated.
•
It is strongly advised that you label wiring to all devices in the system when necessary.
Grounding the VPort 364
Grounding and wire routing help limit the effects of noise due to electromagnetic interference (EMI). Run the
ground connection from the ground screw to the grounding surface prior to connecting devices.
ATTENTION
This product is intended to be mounted to a well-grounded mounting surface such as a metal panel.