Rear Panel 

 

1.

 

Phone jack for audio output 

2.

 

Phone jack for audio input 

3.

 

RJ45 port for PoE/non-PoE connection 

4.

 

Ground screw for connecting a ground wire 

5.

 

3-pin terminal block for power input 

6.

 

LED indicator to show network and system status. Green indicates 
normal operation. 

7.

 

LED indicator to show power status. Green indicates normal 
operation. 

8.

 

9-pin terminal block for RS-485 and DI and relay. 

9-pin terminal block pin assignment 

 

RS-485 

Relay (Relay Output)  DI (Digital Input) 

Tx+/D+  Tx-/D-  Rx+  Rx- 

: NC  : COM  : NO  IN: + 

: GND 

Full/Half duplex RS-485 

Max. 1 A, 24 VDC 
Initial status is NO 
(Normal Open) 

High: +13 V to +30 

Low: -30 V to +3 V 

 

NOTE 

The VPort 36-2L can be powered by a 12 VDC, 24 VDC, or 24 VAC 
input or Power-over-Ethernet (PoE, 802.3af). Input rating is 
12/24 VDC, 0.91/0.38 A or 24 VAC, 47-63 Hz, 0.8 A or PoE 48 
VDC, 0.24 A. Use an external power supply together with PoE 
(802.3af) for power redundancy. 

 

Software Installation 

Step 1: Configure the VPort 36-2L’s IP address 

When the VPort 36-2L is first powered on, the POST (Power On Self Test) 
will run for a few moments (about 90 seconds). The network environment 
determines how the IP address is assigned. 
 

Tx+/D+ Tx-/D- Rx+ Rx- 

Summary of Contents for VPort 36-2L Series

Page 1: ...mericas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 21 5258 5505 Moxa Europe Tel 49 89 3 70 03 99 0 Fax...

Page 2: ...ice representative for assistance 1 VPort 36 2L3X or VPort 36 2L2X camera with a 3 pin terminal block for power input and 9 pin terminal block for RS 485 DI and Relay Quick installation guide printed...

Page 3: ...Product Description Front and Top Panels SD Card Socket The VPort supports the SDXC interface which can use SD cards with more than 64 GB of memory for local storage of video recordings by event or di...

Page 4: ...nput Tx D Tx D Rx Rx NC COM NO IN GND Full Half duplex RS 485 Max 1 A 24 VDC Initial status is NO Normal Open High 13 V to 30 V Low 30 V to 3 V NOTE The VPort 36 2L can be powered by a 12 VDC 24 VDC o...

Page 5: ...web browser to access the VPort s web based manager web server Non DHCP Server Network Environment If your VPort 36 2L is connected to a network that does not have a DHCP server then you will need to...

Page 6: ...security configuration to enable the installation of the VPort s ActiveX Control component Step 4 Access the homepage of the VPort 36 2L s web based manager After installing the ActiveX Control compon...

Page 7: ...nd the default password is moxamoxa Please change the default password for better protection Grounding VPort 36 2L Grounding and wire routing help limit the effects of noise due to electromagnetic int...

Page 8: ...s mounting bracket screw hole Screw in until the lens secures the front glass to the housing Then install the VP CI701 onto the wall mount bracket VP CI800 Indoor installation with indoor mounting bra...

Page 9: ...separate The rule of thumb is that wiring that shares similar electrical characteristics can be bundled together Keep input wiring and output wiring separated It is strongly advised that you label wi...

Reviews: