UC-8112-LX-STK Manual
Hardware Introduction
2-4
Default Operations for Programmable LEDs
Status of the 3 LEDs
Green LED Yellow LED Red LED Status Description
Off
Off
On
SD Card Error – Can’t read from or write to the SD card
Off
On
On
WAN Ethernet Error – WAN Ethernet controller malfunction
On
Off
On
LAN Ethernet Error – LAN Ethernet controller malfunction
Off
Blinking
On
IP Address Error – IP Address conflict; re-configure the UC-8110’s LAN
IP address to solve this problem
Off
Off
Blinking
Power-Off Warning
Power off may result in damage to the UC-8110 due to
•
Updating firmware
•
Saving configuration
•
Initialization process
On
On
On
RS-232 Interface Error
Blinking
Blinking
Blinking
Proceeding with Self Diagnosis
Blinking
Off
Off
Automatic Pairing (Button)
•
Press and hold the button for 2 seconds to enable automatic
pairing mode.
•
Simply click the button “Smart Connect” on the software utility
(Moxa Nexus for Windows, iOS, or Android) on any handheld
device to seamlessly access this device via the Moxa Cloud
Solution.
•
Automatic pairing mode will be disabled after X seconds. (X is
configurable, default is 30.)
•
When automatic pairing mode is enabled, the green “Diagnosis”
LED will keep blinking.
•
Any successful pairing will disable the automatic pairing mode
immediately.
Off
Blinking
Off
Automatic Pairing (QR-Code)
•
Scanning the QR-Code on the UC-8110 from the software utility on
a handheld device will enable automatic pairing mode
•
Refer to “Automatic Pairing (Button)”
•
The only exception is the Yellow “Diagnosis” LED, which will keep
blinking when automatic pairing mode is enabled.
Off
On
Off
Reset to Factory Default
Reset to Default Button
Press and hold the
Reset Button
continuously for at least 5 seconds to load the
factory default
configuration
. After the factory default configuration has been loaded, the system will reboot automatically.
The
Ready
LED will blink on and off for the first 5 seconds, and then maintain a steady glow once the system
has rebooted.
We recommend that you only use this function if the software is not working properly and you want to load
factory default settings. The
Reset to Default
functionality is not designed to hard reboot the UC-8112.
ATTENTION
Reset to Default preserves user’s data
The
Reset to Default
function will NOT format the user directory and erase the user’s data. Using the Reset
to default function will only load the configuration file. The rest of the user’s data stored in the Flash ROM will
remain intact.