Moxa Technologies TSN-G5000 Series Quick Installation Manual Download Page 9

- 9 - 

Wiring Requirements 

 

ATTENTION 

Safety First!

 

Be sure to disconnect the power cord before installing and/or 
wiring your Moxa TSN-G5000 Series. Calculate the maximum 
possible current in each power wire and common wire. Observe 
all electrical codes dictating the maximum current allowable for 
each wire size. If the current goes above the maximum ratings, 
the wiring could overheat, causing serious damage to your 
equipment. 

 

Be sure to read and follow these important guidelines: 

 

Use separate paths to route wiring for power and devices. If power 
wiring and device wiring paths must cross, make sure the wires are 
perpendicular at the intersection point. 
 

NOTE 

Do not run signal or communications wiring and power wiring 
through the same wire conduit. To avoid interference, wires 
with different signal characteristics should be routed separately. 

 

 

 

You can use the type of signal transmitted through a wire to 
determine which wires should be kept separate. The rule of thumb 
is that wiring that shares similar electrical characteristics can be 
bundled together. 

 

You should separate input wiring from output wiring. 

 

We advise that you label the wiring to all devices in the system. 
 

Grounding the TSN-G5000 Series 

Grounding and wire routing help limit the effects of noise due to 
electromagnetic interference (EMI). Run the ground connection from 
the ground screw (chassis ground) to the grounding surface prior to 
connecting devices. The grounding screw is located on the top panel of 
the TSN-G5000 Series. 

 

 

ATTENTION 

This product is intended to be mounted onto a well-grounded 
mounting surface, such as a metal panel. 

 

Summary of Contents for TSN-G5000 Series

Page 1: ...com support Moxa Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 21 5258 5505 Moxa Europe Tel 49 8...

Page 2: ...representative for assistance 1 TSN G5000 Series industrial Ethernet switch 1 RJ45 to RS 232 9 pin female console cable 1 Quick installation guide printed 1 Warranty card 2 Terminal blocks Default Set...

Page 3: ...0BaseT X 6 LED indicator for 10 100BaseT X 7 Ethernet ports x 2 SFP 100 1000BaseSFP 8 Rubber cover for reset button and microSD card slot currently disabled 9 Grounding screw chassis ground 10 Relay o...

Page 4: ...4 Dimensions TSN G5004 TSN G5008 2GTXSFP Unit mm inch...

Page 5: ...TSN G5000 Series on the corrosion free mounting rail that adheres to the EN 60715 standard Suggested Installation Method Step 1 Insert the upper lip of the DIN rail kit into the mounting rail Step 2...

Page 6: ...eres to the EN 60715 standard Default Installation Side Installation Suggested Installation Method Step 1 Detach the metal DIN rail mounting kit from the back panel and attach it to the side panel ver...

Page 7: ...Series should be securely fastened before mounting on the mounting rail Please make sure that if you remove the DIN rail kit it must be securely fastened when it is reattached Wall mounting For some a...

Page 8: ...about 2 mm to allow room for sliding the wall mount panel between the wall and the screws Step 3 Once the screws are fixed in the wall insert the four screw heads through the large parts of the keyho...

Page 9: ...d power wiring through the same wire conduit To avoid interference wires with different signal characteristics should be routed separately You can use the type of signal transmitted through a wire to...

Page 10: ...tor Step 2 Insert the wire Step 3 Release the screwdriver after the wire has been fully inserted Please refer to the diagram below Wiring the Relay Contact The TSN G5000 Series has one relay output fo...

Page 11: ...d one can integrate the relay contact on the TSN G5000 Series with an external alarming system circuit so that the status of user configured events or no power supply can be monitored An example is gi...

Page 12: ...a Low Voltages SELV The TSN G5000 Series has two sets of power inputs power input 1 PWR 1 P1 and power input 2 PWR 2 P2 The top view of the terminal block connector and the positions of the power inpu...

Page 13: ...able following wiring diagrams to connect the TSN G5000 s console port to your PC s COM port You may then use a console terminal program such as Moxa PComm Terminal Emulator to access the TSN G5000 th...

Page 14: ...of device NIC type or HUB Switch type connected to the port In the following section we give pinouts for both MDI NIC type ports and MDI X HUB Switch type ports We also give cable wiring diagrams for...

Page 15: ...ne of the optical lines is used to transmit data from device I to device II and the other optical line is used to transmit data from device II to device I for full duplex transmission Remember to conn...

Page 16: ...o reset the switch to factory default settings and the other is to reboot the switch if the button has been pressed and released immediately This button is located inside the rubber cover on the top p...

Page 17: ...ied to the main system s power input PWR2 SYNC Currently disabled Per Port LED Copper 10 100 1000 Mbps Green On When the port is active and linking at 1000 Mbps Blinking When the data is being transmi...

Page 18: ...mension W x H x D TSN G5004 25 x 135 x 115 mm 0 98 x 5 32 x 4 53 in TSN G5008 2GTXSFP 36 x 135 x 115 mm 1 42 x 5 32 x 4 53 in Weight TSN G5004 582 g 1 28 lb TSN G5008 2GTXSFP 787 g 1 74 lb Installatio...

Page 19: ...ns 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation ATTENTION This product is for indoor u...

Reviews: