Specifications 

Interface 

RJ45 Ports 

10/100/1000BaseT(X) 

Fiber Ports 

100/1000BaseSFP 

Console Port 

RS-232 (RJ45) 

Relay Contact (Relay 
Output) 

1 normally open electromagnetic relays output 
with current carrying capacity of 1 A @ 24 VDC 

Digital Input 

1 isolated digital input: 
• +13 to +30 V for state “1” 
• -30 to +3 V for state “0” 
• Max. input current: 8 mA 

Button 

Reset button 

Power Requirements 

Rated Input Voltage 

12-48 VDC, redundant dual inputs 

Input Current 

TSN-G5004: 1.25 A @ 12 V 
TSN-G5008-2GTXSFP: 1.72 A @ 12 V 

Connection 

2 removable 4-contact terminal blocks 

Overload Current 
Protection 

Supported 

Reverse Polarity 
Protection 

Supported 

Physical Characteristics 

Housing 

Metal   

IP Rating 

IP40 

Dimension (W x H x D)  TSN-G5004: 25 x 135 x 115 mm (0.98 x 5.32 

x 4.53 in) 
TSN-G5008-2GTXSFP: 36 x 135 x 115 mm 
(1.42 x 5.32 x 4.53 in) 

Weight 

TSN-G5004: 582 g (1.28 lb) 
TSN-G5008-2GTXSFP: 787 g (1.74 lb) 

Installation 

DIN-rail mounting, wall mounting (with 
optional kit) 

Environmental Limits 

Operating Temperature  -10 to 60°C (14 to 140°F) 
Storage Temperature  -40 to 85°C (-40 to 185°F) 
Ambient Relative 
Humidity 

5% to 95% (non-condensing) 

Altitude 

Up to 2000 m 
Note: Please contact Moxa if you require 
products guaranteed to function properly at 
higher altitude. 

Standards and Certifications 

Safety 

UL 61010-2-201, EN 62368-1 

EMC 

EN 55035/55032 

EMI 

CISPR 32, FCC Part 15B Class A 

EMS 

IEC 61000-4-2 ESD: Contact: 6 kV; Air: 8 kV 
IEC 61000-4-3 RS: 80 MHz to 1 GHz: 10 V/m   
IEC 61000-4-4 EFT: Power: 2 kV; Signal: 1 kV     
IEC 61000-4-5 Surge: Power: 2 kV; Signal: 1 
kV 
IEC 61000-4-6 CS: Signal: 10 V 
IEC 61000-4-8 PFMF: 100 A/m, 60 s 
 

Summary of Contents for TSN-G5000 Series

Page 1: ...com support Moxa Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 21 5258 5505 Moxa Europe Tel 49 8...

Page 2: ...representative for assistance 1 TSN G5000 Series industrial Ethernet switch 1 RJ45 to RS 232 9 pin female console cable 1 Quick installation guide printed 1 Warranty card 2 Terminal blocks Default Set...

Page 3: ...0BaseT X 6 LED indicator for 10 100BaseT X 7 Ethernet ports x 2 SFP 100 1000BaseSFP 8 Rubber cover for reset button and microSD card slot currently disabled 9 Grounding screw chassis ground 10 Relay o...

Page 4: ...4 Dimensions TSN G5004 TSN G5008 2GTXSFP Unit mm inch...

Page 5: ...TSN G5000 Series on the corrosion free mounting rail that adheres to the EN 60715 standard Suggested Installation Method Step 1 Insert the upper lip of the DIN rail kit into the mounting rail Step 2...

Page 6: ...eres to the EN 60715 standard Default Installation Side Installation Suggested Installation Method Step 1 Detach the metal DIN rail mounting kit from the back panel and attach it to the side panel ver...

Page 7: ...Series should be securely fastened before mounting on the mounting rail Please make sure that if you remove the DIN rail kit it must be securely fastened when it is reattached Wall mounting For some a...

Page 8: ...about 2 mm to allow room for sliding the wall mount panel between the wall and the screws Step 3 Once the screws are fixed in the wall insert the four screw heads through the large parts of the keyho...

Page 9: ...d power wiring through the same wire conduit To avoid interference wires with different signal characteristics should be routed separately You can use the type of signal transmitted through a wire to...

Page 10: ...tor Step 2 Insert the wire Step 3 Release the screwdriver after the wire has been fully inserted Please refer to the diagram below Wiring the Relay Contact The TSN G5000 Series has one relay output fo...

Page 11: ...d one can integrate the relay contact on the TSN G5000 Series with an external alarming system circuit so that the status of user configured events or no power supply can be monitored An example is gi...

Page 12: ...a Low Voltages SELV The TSN G5000 Series has two sets of power inputs power input 1 PWR 1 P1 and power input 2 PWR 2 P2 The top view of the terminal block connector and the positions of the power inpu...

Page 13: ...able following wiring diagrams to connect the TSN G5000 s console port to your PC s COM port You may then use a console terminal program such as Moxa PComm Terminal Emulator to access the TSN G5000 th...

Page 14: ...of device NIC type or HUB Switch type connected to the port In the following section we give pinouts for both MDI NIC type ports and MDI X HUB Switch type ports We also give cable wiring diagrams for...

Page 15: ...ne of the optical lines is used to transmit data from device I to device II and the other optical line is used to transmit data from device II to device I for full duplex transmission Remember to conn...

Page 16: ...o reset the switch to factory default settings and the other is to reboot the switch if the button has been pressed and released immediately This button is located inside the rubber cover on the top p...

Page 17: ...ied to the main system s power input PWR2 SYNC Currently disabled Per Port LED Copper 10 100 1000 Mbps Green On When the port is active and linking at 1000 Mbps Blinking When the data is being transmi...

Page 18: ...mension W x H x D TSN G5004 25 x 135 x 115 mm 0 98 x 5 32 x 4 53 in TSN G5008 2GTXSFP 36 x 135 x 115 mm 1 42 x 5 32 x 4 53 in Weight TSN G5004 582 g 1 28 lb TSN G5008 2GTXSFP 787 g 1 74 lb Installatio...

Page 19: ...ns 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation ATTENTION This product is for indoor u...

Reviews: