Moxa Technologies ToughNet TN-5524-8PoE Quick Installation Manual Download Page 2

- 2 - 

Overview 

The ToughNet TN-5524-8PoE series M12 managed Ethernet switches are 
designed for industrial applications in harsh environments. The TN series 
switches use M12 and other circular connectors to ensure tight, robust 
connections, and guarantee reliable operation against environmental 
disturbances, such as vibration and shock. The TN-5524-8PoE series 
switches provide 24 Fast Ethernet M12 ports, 8 of which are 
10/100BaseT(X) PoE compliant. 
TN-5524-8PoE switches provide up to 15.4 watts of power per PoE port, 
and allow power to be supplied to connected devices (such as surveillance 
cameras, wireless access points, and IP phones) when AC power is not 
readily available or is cost-prohibitive to provide locally. Models with an 
extended operating temperature range of -40 to 75°C are also available. 
The TN-5524-8PoE series Ethernet switches are compliant with 
mandatory sections of EN 50155, covering operating temperature, power 
input voltage, surge, ESD, and vibration, as well as conformal coating and 
power insulation, making the switches suitable for a variety of industrial 
applications. 

Package Checklist 

Your ToughNet TN-5524-8PoE switch is shipped with the following items. 
If any of these items is missing or damaged, contact your customer 
service representative for assistance. 

 

1 Moxa ToughNet switch 

 

M12 to DB9 console port cable 

 

2 protective caps for console and relay output ports 

 

Panel mounting kit  

 

CD-ROM with user’s manual, Windows utility, and SNMP MIB file 

 

Quick installation guide (printed) 

 

Warranty card 

Features 

Anti-Vibration Circular Connectors for Robust Links 

 

M12 D-coding 4-pin female connectors for Fast Ethernet 
10/100BaseT(X) ports 

 

M12 A-coding 5-pin male connectors for console and relay output 

 

M23 6-pin male connector for power input 

Isolated Power Input 

 

Supports 24 VDC (16.8 to 30 VDC), isolated 

High Performance Network Switching Technology 

 

IPv6 ready, certified by the IPv6 Logo Committee 

 

IEEE 1588 PTP (Precision Time Protocol) for the precise time 
synchronization of networks 

 

DHCP Option 82 for IP address assignment with different policies 

 

Modbus/TCP industrial Ethernet protocol 

 

Turbo Ring, Turbo Chain,and RSTP/STP (IEEE802.1w/D) 

 

IGMP Snooping and GMRP for filtering multicast traffic from industrial 
Ethernet protocols 

 

Port-based VLAN, IEEE802.1Q VLAN, and GVRP protocol to ease 
network planning 

 

QoS (IEEE802.1p/1Q and TOS/DiffServ) to increase determinism 

Summary of Contents for ToughNet TN-5524-8PoE

Page 1: ...ort Moxa Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 21 5258 5505 Moxa Europe Tel 49 89 3 70 03...

Page 2: ...ckage Checklist Your ToughNet TN 5524 8PoE switch is shipped with the following items If any of these items is missing or damaged contact your customer service representative for assistance 1 Moxa Tou...

Page 3: ...ating temperature range for T models IP40 rugged high strength housing Panel mounting mounting installation capability This product is suitable for rolling stock railway applications as defined by the...

Page 4: ...n shielded M23 connector 7 PWR1 LED for power input 1 8 PWR2 LED for power input 2 9 FAULT LED 10 MSTR HEAD LED for ring master or chain head 11 CPLR TAIL LED for ring coupler or chain tail 12 TP port...

Page 5: ...sliding the ToughNet switch between the wall and the screws NOTE Before tightening the screws into the wall make sure the screw head and shaft size are suitable by inserting the screw through one of...

Page 6: ...trical codes dictating the maximum current allowable for each wire size If the current goes above the maximum ratings the wiring could overheat causing serious damage to your equipment Be sure to read...

Page 7: ...r input port on the TN 5524 8PoE Pinouts for the power input port on the TN 5524 8PoE Pin Description Usage 1 PWR1 Live DC Connect PWR1 Live DC to the Live terminal when using an AC power source or to...

Page 8: ...contacts form an open circuit when a user configured event is triggered If a user configured event does not occur the fault circuit remains closed Connecting the Data Lines 10 100BaseT X Ethernet Port...

Page 9: ...uts Pin Signal 1 Tx 2 Tx 3 Rx 6 Rx Pin Signal 1 Rx 2 Rx 3 Tx 6 Tx M12 4 pin M to M12 4 pin M Cross Over Cable Wiring M12 4 pin M to M12 4 pin M Straight Trough Cable Wiring M12 4 pin M to RJ45 8 pin C...

Page 10: ...Chain Blinking When the TN switch is Ring Master of this Turbo Ring and the Turbo Ring is broken or it is Chain Head of this Turbo Chain and the Turbo Chain is broken OFF When the TN switch is neithe...

Page 11: ...ity Queues 4 Max Number of Available VLANs 64 VLAN ID Range VID 1 to 4094 IGMP Groups 256 Interface Fast Ethernet Front cabling M12 connector 10 100BaseT X auto negotiation speed F H duplex mode and a...

Page 12: ...er 2 kV Signal 2 kV IEC 61000 4 6 CS 10 V IEC 61000 4 8 Rail Traffic for panel mounting installations EN 50155 EN 50121 4 EN 45545 2 This product is suitable for rolling stock railway applications as...