Moxa Technologies ToughNet TN-5524-8PoE Quick Installation Manual Download Page 10

- 10 - 

LED Indicators 

Several LED indicators are located on the ToughNet switch’s front panel. 
The function of each LED is described in the table below. 

LED 

Color 

State 

Description 

System LEDs 

PWR1 

AMBER 

ON 

Power is being supplied to power input 
PWR1. 

OFF 

Power is not being supplied to power 
input PWR1 

PWR2 

AMBER 

ON 

Power is being supplied to power input 
PWR2. 

OFF 

Power is not being supplied to power 
input PWR2. 

FAULT 

RED 

ON 

When the corresponding PORT alarm is 
enabled, and a user-configured event is 
triggered. 

OFF 

When the corresponding PORT alarm is 
enabled and a user-configured event is 
not triggered, or when the 
corresponding PORT alarm is disabled. 

MSTR/ 

HEAD 

GREEN 

ON 

When the TN switch is either the Master 
of this Turbo Ring, or the Head of this 
Turbo Chain. 

Blinking 

When the TN switch is Ring Master of 
this Turbo Ring and the Turbo Ring is 
broken, or it is Chain Head of this Turbo 
Chain and the Turbo Chain is broken. 

OFF 

When the TN switch is neither the 
Master of this Turbo Ring, nor the Head 
of this Turbo Chain. 

CPLR/ 

TAIL 

GREEN 

ON 

When the TN switch enables the 
coupling function to form a back-up path 
in this Turbo Ring, or it is the Tail of this 
Turbo Chain. 

Blinking  When the Turbo Chain is down. 

OFF 

When the TN switch disables the 
coupling function of Turbo Ring, or it is 
not the Tail of the Turbo Chain. 

Ports LEDs 

TP 

(10/100M) 

AMBER 

ON 

TP port’s 10 Mbps link is active. 

Blinking  Data is being transmitted at 10 Mbps. 

Off 

TP port’s 10 Mbps link is inactive. 

GREEN 

On 

TP port’s 100 Mbps link is active. 

Blinking  Data is being transmitted at 100 Mbps. 

off 

TP port’s 100 Mbps link is inactive. 

PoE 

AMBER 

On 

Power is being supplied to a Powered 
Device (PD) 

Off 

Power is not being supplied to a Powered 
Device (PD) 

 

Summary of Contents for ToughNet TN-5524-8PoE

Page 1: ...ort Moxa Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 21 5258 5505 Moxa Europe Tel 49 89 3 70 03...

Page 2: ...ckage Checklist Your ToughNet TN 5524 8PoE switch is shipped with the following items If any of these items is missing or damaged contact your customer service representative for assistance 1 Moxa Tou...

Page 3: ...ating temperature range for T models IP40 rugged high strength housing Panel mounting mounting installation capability This product is suitable for rolling stock railway applications as defined by the...

Page 4: ...n shielded M23 connector 7 PWR1 LED for power input 1 8 PWR2 LED for power input 2 9 FAULT LED 10 MSTR HEAD LED for ring master or chain head 11 CPLR TAIL LED for ring coupler or chain tail 12 TP port...

Page 5: ...sliding the ToughNet switch between the wall and the screws NOTE Before tightening the screws into the wall make sure the screw head and shaft size are suitable by inserting the screw through one of...

Page 6: ...trical codes dictating the maximum current allowable for each wire size If the current goes above the maximum ratings the wiring could overheat causing serious damage to your equipment Be sure to read...

Page 7: ...r input port on the TN 5524 8PoE Pinouts for the power input port on the TN 5524 8PoE Pin Description Usage 1 PWR1 Live DC Connect PWR1 Live DC to the Live terminal when using an AC power source or to...

Page 8: ...contacts form an open circuit when a user configured event is triggered If a user configured event does not occur the fault circuit remains closed Connecting the Data Lines 10 100BaseT X Ethernet Port...

Page 9: ...uts Pin Signal 1 Tx 2 Tx 3 Rx 6 Rx Pin Signal 1 Rx 2 Rx 3 Tx 6 Tx M12 4 pin M to M12 4 pin M Cross Over Cable Wiring M12 4 pin M to M12 4 pin M Straight Trough Cable Wiring M12 4 pin M to RJ45 8 pin C...

Page 10: ...Chain Blinking When the TN switch is Ring Master of this Turbo Ring and the Turbo Ring is broken or it is Chain Head of this Turbo Chain and the Turbo Chain is broken OFF When the TN switch is neithe...

Page 11: ...ity Queues 4 Max Number of Available VLANs 64 VLAN ID Range VID 1 to 4094 IGMP Groups 256 Interface Fast Ethernet Front cabling M12 connector 10 100BaseT X auto negotiation speed F H duplex mode and a...

Page 12: ...er 2 kV Signal 2 kV IEC 61000 4 6 CS 10 V IEC 61000 4 8 Rail Traffic for panel mounting installations EN 50155 EN 50121 4 EN 45545 2 This product is suitable for rolling stock railway applications as...

Reviews: