![Moxa Technologies PT-G7728 User Manual Download Page 110](http://html.mh-extra.com/html/moxa-technologies/pt-g7728/pt-g7728_user-manual_1842658110.webp)
PT-G7828/G7728
Featured Functions
3-98
Temperature (°C) – Current Fiber connection current temperature.
Temperature (°C) – Max.
Fiber connection Max. temperature threshold.
Tx power (dBm) – Current
The current amount of light being transmitted into the fiber optic cable.
Tx power (dBm) – Max.
The Max. threshold of light being transmitted into the fiber optic cable.
Tx power (dBm) - Min.
The Min. threshold of light being transmitted into the fiber optic cable.
Rx power (dBm) – Current
The current amount of light being received from the fiber optic cable.
Rx power (dBm) – Max.
The Max. threshold of light being received from the fiber optic cable.
Fiber Check Threshold Values
Model Name
Temperature
Threshold (°C)
Tx Power (Max./Min.)
(dBm)
Rx Power (Min.)
(dBm)
FEMST
120
-11.0/-23.0
-31.0
FEMSC
120
-11.0/-23.0
-31.0
FESSC
120
3.0/-8.0
-34.0
SFP-1FEMLC-T
120
-5.0/-21.0
-37.0
SFP-1FESLC-T
120
3.0/-8.0
-37.0
SFP-1FELLC-T
120
3.0/-8.0
-37.0
SFP-1GSXLC-T
110
-1.0/-12.5
-18.0
SFP-1GLSXLC-T
120
2.0/-12.0
-19.0
SFP-1GLXLC-T
120
0.0/-12.5
-20.0
SFP-1GLHLC-T
120
1.0/-11.0
-23.0
SFP-1GLHXLC-T
120
4.0/-7.0
-24.0
SFP-1GZXLC-T
120
8.0/-3.0
-24.0
SFP-1G10ALC-T
120
0.0/-12.0
-21.0
SFP-1G10BLC-T
120
-5.0/-21.0
-34.0
SFP-1G20ALC-T
120
1.0/-11.0
-23.0
SFP-1G20BLC-T
120
-5.0/-21.0
-34.0
SFP-1G40ALC-T
120
5.0/-6.0
-23.0
SFP-1G40BLC-T
120
-5.0/-21.0
-34.0
SFP-1GSXLC
100
-1.0/-12.5
-18.0
SFP-1GLSXLC
100
2.0/-12.0
-19.0
SFP-1GLXLC
100
0.0/-12.5
-20.0
SFP-1GLHLC
100
1.0/-11.0
-23.0
SFP-1GLHXLC
100
4.0/-7.0
-24.0
SFP-1GZXLC
100
8.0/-3.0
-24.0
SFP-1GEZXLC
100
8.0/-3.0
-30.0
SFP-1GEZXLC-120
100
6.0/-5.0
-33.0
SFP-1G10ALC
100
0.0/-12.0
-21.0
SFP-1G10BLC
100
-5.0/-21.0
-34.0
SFP-1G20ALC
100
1.0/-11.0
-23.0
SFP-1G20BLC
100
-5.0/-21.0
-34.0
SFP-1G40ALC
100
5.0/-6.0
-23.0
SFP-1G40BLC
100
-5.0/-21.0
-34.0
NOTE
Certain tolerances exist between real data and measured data.
www.ipc2u.ru
www.moxa.pro