ATTENTION
Do not locate the antenna near overhead power lines or other
electric light or power circuits, or where it can come into contact
with such circuits. When installing the antenna, take extreme
care not to come into contact with such circuits, because they
may cause serious injury or death when there is a surge. For
instructions on proper installation and grounding of the antenna,
refer to national and local codes (for example, U.S.: NFPA 70,
National Electrical Code, Article 810, and Canada: Canadian
Electrical Code, Section 54).
ATTENTION
For EXPLOSION-PROOF applications, the OnCell G3150A-LTE is
designed and certified to meet ATEX and IECEx requirements.
You should mount the device in a suitable enclosure rated at least
IP54, in accordance with IEC/EN 60079-15 standard, so that it is
accessible only by the use of a tool. The device is not intended for
use in an area with pollution degree rating > 2 in accordance with
EN 60664-1.
When you install the OnCell G3150A-LTE in an enclosure, the
antennas must also be installed in such a way that they are inside
the enclosure. External antenna deployment is allowed only if the
antennas are certified for ATEX Zone 2 use or confirm to IECEx
standards.
WARNING
EXPLOSION HAZARD!
Do not disconnect equipment unless you have removed the
power source to the equipment or the area is known to be
non-hazardous.
ATEX Zone 2 Certification Information
Demko 16 ATEX 1812X
II 3 G Ex nA IIC T5 Gc
Ambient Range:
-30°C
≦
Tamb
≦
+70°C
IECEx UL 16.0166X
Hazardous Location Standards
EN 60079-0:2012+A11:2013 / IEC 60079-0 6th Edition
EN 60079-15: 2010 / IEC 60079-15 4th Edition
Input Terminal Block Information
Input Terminal Block (J3) is suitable for 12-28 AWG (3.31-0.0804 mm
2
)
wire size, torque value 4.5 lb-in (0.51 Nm).