MPC-2121/2101 Series Win 7 UM
Utilities
3-2
Serial Interface Utility
The Serial Interface utility can be used to configure different serial modes on the MC-2121 computer. The
MC-2121 supports the serial modes
RS232, RS485-2-wire
and
RS422/RS485-4-wire
.
Follow these steps to change the serial interface mode settings.
1.
From the Start menu, Click
All Programs >Moxa >mxSetSerialInterface
.
2.
Select the port, for which you want to set the mode, from the
Port
combo box.
3.
Select the mode for the port.
4.
Click
OK
.