Use a torque of 4Kgf-cm to secure the mounting screws to fasten the 
panel-mounting kit onto the wall. 

 

VESA Mounting 

The MPC-2120 is provided with VESA-mounting holes on the back panel, 
which you can use directly without the need for an adapter. The 
dimension of the VESA mounting area is 50 mm x 75 mm. You will require 
four 6-mm M4 screws to VESA mount the MPC-2120. 

 

 
 

 

Summary of Contents for MPC-2070 Series

Page 1: ...Americas Toll free 1 888 669 2872 Tel 1 714 528 6777 Fax 1 714 528 6778 Moxa China Shanghai office Toll free 800 820 5036 Tel 86 21 5258 9955 Fax 86 21 5258 5505 Moxa Europe Tel 49 89 3 70 03 99 0 Fax 49 89 3 70 03 99 99 Moxa Asia Pacific Tel 886 2 8919 1230 Fax 886 2 8919 1231 Moxa India Tel 91 80 4172 9088 Fax 91 80 4132 1045 2018 Moxa Inc All rights reserved ...

Page 2: ...terfaces as well as high speed IT communications all with native network redundancy Package Checklist Before installing the MPC 2120 verify that the package contains the following items 1 MPC 2120 panel computer 1 2 pin terminal block for DC power input 1 10 pin terminal block for DIO 1 2 pin terminal block for remote power switch 8 panel mounting screws Quick installation guide printed Warranty c...

Page 3: ... For details on the dimensions and the cabinet space required to panel mount the MPC 2120 refer to the following illustration To install the panel mounting kit on the MPC 2120 place the mounting units in the holes provided on the rear panel and push the units to the left as shown in the illustration below ...

Page 4: ...ing kit onto the wall VESA Mounting The MPC 2120 is provided with VESA mounting holes on the back panel which you can use directly without the need for an adapter The dimension of the VESA mounting area is 50 mm x 75 mm You will require four 6 mm M4 screws to VESA mount the MPC 2120 ...

Page 5: ... Press and hold for 4 seconds Power off Brightness Press Manually increase the brightness of the panel Brightness Press Manually decrease the brightness of the panel ATTENTION The MPC 2120 comes with a 1000 nit display the brightness level of which is adjustable up to level 10 The display is optimized for use in the 40 to 70 C temperature range However if you are operating the MPC 2120 at an ambie...

Page 6: ... 485 4 wire RS 485 2 wire 1 DCD TxDA TxDA 2 RxD TxDB TxDB 3 TxD RxDB RxDB DataB 4 DTR RxDA RxDA DataA 5 GND GND GND GND 6 DSR 7 RTS 8 CTS Ethernet Ports The pin assignments for the two Fast Ethernet 100 1000 Mbps RJ45 ports are shown in the following table Pin 100 Mbps 1000 Mbps 1 ETx TRD 0 2 ETx TRD 0 3 ERx TRD 1 4 TRD 2 5 TRD 2 6 ERx TRD 1 7 TRD 3 8 TRD 3 The LEDs on the LAN ports indicate the f...

Page 7: ...ides two storage options CFast and SD card The storage slots are located on the left panel You can install the OS on the CFast card and save your data into the SD card For a list of compatible CFast models check the MPC 2120 component compatibility report available on Moxa s website To install the storage devices do the following 1 Remove the 2 screws holding the storage slot cover to the MPC 2120...

Page 8: ...C 2120 Connect a Terminal Block to Power Jack Converter to the MPC 2120 terminal block and connect a 60 W power adapter to the converter Supply power through the power adapter After you have connected a power source the system power turns on automatically It takes about 10 to 30 seconds for the system to boot up You can change the power on behavior of your computer by changing the BIOS settings To...

Page 9: ...yyy I II III I Screen size MPC 2070 7 panel MPC 2120 12 panel II CPU type E2 Intel Atom Processor E3826 1 46 GHz E4 Intel Atom Processor E3845 1 91 GHz MPC 2120 series only III Marketing purpose 0 to 9 A to Z dash blank or any character for marketing purpose Rating For model MPC 2070 E2 yyyyyyyyy 12 24 VDC 2 5 A or 24 VDC 1 25 A or 12 VDC 2 5 A For model MPC 2120 xx yyyyyyyyy 12 24 VDC 3 5 A or 24...

Page 10: ...gree 2 in accordance with IEC EN 60664 1 Subject devices are intended for use in low risk of mechanical impact environments The equipment shall be installed panel mount to an enclosure that provides a degree of protection not less than IP54 in accordance with IEC EN 60079 15 and accessible only by use of a tool Hazardous Location Standard EN 60079 0 2012 A11 2013 EN 60079 15 2010 IEC 60079 0 6th E...

Reviews: