Moxa Technologies MGate EIP3000 User Manual Download Page 8

 

2

2

 

 

Chapter 2 

Getting Started 

This chapter provides basic instructions for installing the MGate EIP3000.  

The following topics are covered: 

 

‰

 

Connecting Power 

‰

 

Connecting Serial Devices 

‰

 

Connecting to a Host or the Network 

‰

 

Installing the Software 

‰

 

Mounting the Unit 

 

RSPSupply  -  1-888-532-2706 -  www.RSPSupply.com

http://www.RSPSupply.com/p-9617-Moxa-MGate-EIP3270I.aspx

Summary of Contents for MGate EIP3000

Page 1: ...ay User s Manual First Edition June 2009 www moxa com product 2009 Moxa Inc All rights reserved Reproduction without permission is prohibited RSPSupply 1 888 532 2706 www RSPSupply com http www RSPSup...

Page 2: ...or changes to this manual or to the products and or the programs described in this manual at any time Information provided in this manual is intended to be accurate and reliable However Moxa assumes...

Page 3: ...P3270I 4 1 Panel Layout 4 2 LED Indicators 4 2 Dimensions 4 3 Jumpers 4 4 Pin Assignments 4 5 DB9 Male 4 5 Power Input Relay Output 4 5 DIN Rail Wall Mounting 4 6 Specifications 4 7 Chapter 5 Configur...

Page 4: ...lter Traffic Information 5 19 Save Log to File 5 20 Upgrading Firmware 5 20 Chapter 6 Pin Assignments 6 1 DB9 Male 6 2 Terminal Block RS 422 6 3 Power Input Relay Output 6 3 RSPSupply 1 888 532 2706 w...

Page 5: ...om DF1 to EtherNet IP and RS 232 422 ports for DF1 communication One port and two port models are available This chapter is an introduction to the MGate EIP3000 and includes the following sections Ove...

Page 6: ...l serial port function gives RSLinx or some SCADA systems the capability to connect to multiple DF1 and EtherNet IP devices through a protocol gateway Windows utilities for easy setup and traffic moni...

Page 7: ...vided y ProCOM function provides virtual serial port for multiple DF1 and EtherNet IP device communication y Embedded EtherNet IP and DF1 protocol analyzer y Redundant dual DC power inputs y Built in...

Page 8: ...talling the MGate EIP3000 The following topics are covered Connecting Power Connecting Serial Devices Connecting to a Host or the Network Installing the Software Mounting the Unit RSPSupply 1 888 532...

Page 9: ...9 cable to connect a serial device to the unit Plug one end of the cable into the port on the unit s back panel and plug the other end of the cable into the device s serial port y You may make your ow...

Page 10: ...gement utility is installed from the Document and Software CD Follow the onscreen instructions after inserting the CD Mounting the Unit The unit can be mounted on the wall or mounted on a DIN Rail RSP...

Page 11: ...0 and EIP3170I The following topics are covered Panel Layout LED Indicators Dimensions Jumpers Pin Assignments DB9 Male Terminal Block RS 422 Power Input Relay Output DIN Rail Wall Mounting Specificat...

Page 12: ...reen Steady on Power is on and unit is functioning normally Blinking Unit is responding to software Locate function RDY Off Power is off or power error condition exists Orange 10 Mbps Ethernet connect...

Page 13: ...5 mm 2 74 in 25 9 mm 1 02 in 35 mm 1 38 in 20 6 mm 0 81 in 29 91 mm 1 18 in 11 5 mm 0 45 in 124 5 mm 4 9 in 118 5 mm 4 67 in 89 2 mm 3 51 in 14 5 mm 0 57 in 29 mm 1 14 in 14 5 mm 0 57 in 3 3 RSPSupply...

Page 14: ...igh low resistors to 150 K set switches 1 and 2 to OFF This is the default setting To set the pull high low resistors to 1 K set switches 1 and 2 to ON Switch 4 on the port s assigned DIP switch is re...

Page 15: ...ions to DF1 devices 1 5 6 9 Pin RS 232 1 DCD 2 RxD 3 TxD 4 DTR 5 GND 6 DSR 7 RTS 8 CTS Terminal Block RS 422 The MGate EIP3170 and EIP3170I use a terminal block connector for RS 422 connections to DF1...

Page 16: ...DIN Rail Wall Mounting There are two sliders on the back of the unit for DIN Rail and wall mounting Mounting on a DIN Rail Pull out the bottom slider latch the unit onto the DIN Rail and push the slid...

Page 17: ...CTS DTR DSR Transmission Speed 1200 bps to 921 6 Kbps Software Features Utilities MGate Manager Multi Request 8 simultaneous EtherNet IP clients with up to 16 simultaneous requests per client Protocol...

Page 18: ...Gate EIP3270 and EIP3270I The following topics are covered Panel Layout LED Indicators Dimensions Jumpers Pin Assignments DB9 Male Power Input Relay Output DIN Rail Wall Mounting Specifications RSPSup...

Page 19: ...een Steady on Power is on and unit is functioning normally Blinking Unit is responding to software Locate function RDY Off Power is off or power error condition exists Orange 10 Mbps Ethernet connecti...

Page 20: ...5 mm 2 74 in 25 9 mm 1 02 in 35 mm 1 38 in 20 6 mm 0 81 in 29 91 mm 1 18 in 11 5 mm 0 45 in 124 5 mm 4 9 in 118 5 mm 4 67 in 89 2 mm 3 51 in 14 5 mm 0 57 in 29 mm 1 14 in 14 5 mm 0 57 in 4 3 RSPSupply...

Page 21: ...ors to 150 K set switches 1 and 2 on the port s assigned DIP switch to OFF This is the default setting To set the pull high low resistors to 1 K set switches 1 and 2 on the port s assigned DIP switch...

Page 22: ...ts two serial interfaces RS 232 and RS 422 1 5 6 9 Pin RS 232 RS 422 1 DCD TxD 2 RxD TxD 3 TxD RxD 4 DTR RxD 5 GND GND 6 DSR 7 RTS 8 CTS Power Input Relay Output V2 V2 V1 V1 Shielded Ground DC Power I...

Page 23: ...DIN Rail and wall mounting Mounting on a DIN Rail Pull out the bottom slider latch the unit onto the DIN Rail and push the slider back in Mounting on the wall Pull out both the top and bottom sliders...

Page 24: ...ed 1200 bps to 921 6 Kbps Software Features Utilities MGate Manager Multi Request 8 simultaneous EtherNet IP clients with up to 16 simultaneous requests per client Protocol Ethernet CIP PCCC on EtherN...

Page 25: ...ge Se Connecting to the Unit Broadcast Search Specify by IP Addre Modifying the Configur Configure IP Address a Configure Serial Communi Set up Routing and ProCOM function Set up Protocol Set Up Misce...

Page 26: ...work 1 Insert the Document and Software CD into the CD ROM drive Locate and run the following setup program to begin the installation process MGM_Setup_ Version _Build_ DateTime exe The latest version...

Page 27: ...ue You may change the destination directory by first clicking on Browse 4 When the Select Additional Tasks window appears click Next to continue You may select Create a desktop icon if you would like...

Page 28: ...erNet IP Gateway 5 Click Next to start copying the software files 6 A progress bar will appear The procedure should take only a few seconds to complete 5 4 RSPSupply 1 888 532 2706 www RSPSupply com h...

Page 29: ...Manager is successfully installed You may choose to run it immediately by selecting Launch MGate Manager 8 You may also open MGate Manager through Start Programs MGate Manager MGate Manager as shown...

Page 30: ...refer to Chapter 2 for more details You may open MGate Manager from the Windows Start menu by clicking Start Programs MGate Manager MGate Manager The MGate Manager window should appear as shown below...

Page 31: ...e active for the current MGate Manager session When you open MGate Manager again the language will revert to your original setting Connecting to the Unit MGate Manager needs to connect to the unit bef...

Page 32: ...ith MAC address and IP address Simply select the one that you wish to configure Specify by IP Address Click Specify by IPAddress if you know the IP address of the unit and wish to connect to it direct...

Page 33: ...e EIP3000 is located on the same LAN as your PC but on a different subnet In this case you can modify your PC s IP address and or netmask so that it is on the same subnet as the MGate EIP3000 After yo...

Page 34: ...tc Network Configuration Static IP DHCP BootP or DHCP BootP Select Static IP if you are using a fixed IP address Select one of the other options if the IP address is set dynamically IP1 Address 192 16...

Page 35: ...ic string Re type the password again for confirmation ATTENTION Both IP1 and IP2 all can be set manually Since IP1 is the main IP address please assign the IP2 address to the same network subnet as IP...

Page 36: ...rial Communication Parameters The Serial tab is where each serial port s communication parameters are configured You can configure Baud Rate Parity Stop Bit Flow Control FIFO and Interface Mode Parame...

Page 37: ...OM 3 4 5 6 If you would like to connect to an EIP interface EtherNet IP device you must configure the relationship between Node DST and Target Node IP of the EIP interface device manually Another rout...

Page 38: ...it were an additional serial port on the EIP3000 Before using this powerful function you must complete ProCOM mapping After finding the EIP3000 with the search function select the EIP3000 device for w...

Page 39: ...out since it requires at least double the timeout values of DF1 ACK after the EIP3000 forwards a PCCC command and before it gets a response ACK timeout for DF1 settings defines how much time the EIP30...

Page 40: ...ect and Telnet Console The auto relay warning includes power failure Ethernet 1 or 2 links down to trigger relay warning If any checked trigger condition occurs the EIP3000 will open the circuit of th...

Page 41: ...itoring EtherNet IP Activity For troubleshooting or management purposes you can monitor the data passing through any MGate EIP3000 on the network Data events will be logged as they pass through the ga...

Page 42: ...nit that you wish to monitor and click Monitor to open the Traffic Monitor window In the Traffic Monitor window click Start to begin live monitoring of the data passing through the selected MGate EIP3...

Page 43: ...nager also allows the data to be filtered so only the relevant information is displayed The filter is selected using the radio buttons and customized using the Filter info field as follows Filter Desc...

Page 44: ...e Firmware updates for the MGate EIP3000 are located at www moxa com After you have downloaded the new firmware onto your PC you can use MGate Manager to write it onto your MGate EIP3000 Select the de...

Page 45: ...mware is written to the unit progress is displayed in the window Once the firmware has been successfully written onto the unit click Exit to close the Upgrade Firmware window MGate Manager will automa...

Page 46: ...n Assignments We discuss the following topics in this chapter DB9 Male Terminal Block RS 422 Power Input Relay Output RSPSupply 1 888 532 2706 www RSPSupply com http www RSPSupply com p 9617 Moxa MGat...

Page 47: ...ach port supports two serial interfaces RS 232 and RS 422 1 5 6 9 Pin RS 232 RS 422 1 DCD TxD 2 RxD TxD 3 TxD RxD 4 DTR RxD 5 GND GND 6 DSR 7 RTS 8 CTS EIP3170 EIP3170I Pin RS 232 1 DCD 2 RxD 3 TxD 4...

Page 48: ...connector for RS 422 signal Pin RS 422 1 TxD 2 TxD 3 RxD 4 RxD 5 GND Power Input Relay Output V2 V2 V1 V1 Shielded Ground DC Power Input 1 DC Power Input 1 Relay Output Relay Output DC Power Input 2...