Industrial I/O

Patented Automatic Tag Generation

Patented “Auto Tag Generation” eliminates the headache of specifying 
target IP addresses, I/O channels, and data formats one by one, or 
editing and importing configuration text files since Active OPC Server 
Lite creates the tags for the target ioLogik automatically. One of the 

biggest payoffs is that users will no longer need to be trained to install 
and configure your OPC system, since setting up Active OPC Server 
Lite is done automatically with a single click of the mouse.

ioLogik

It takes 5 seconds to create 20 or more tags

It takes 2.5 min.
to create only
1 tag

General OPC Server

Create Tags

Create Tags

5 steps for channels, interfaces, and protocol definition: takes 

20

 seconds.

13 steps for device, IP address, and other communication parameters: takes 

30

 seconds.

Select channels and press                  button to update configuration: takes 5 seconds.

1 step for looking up address table: takes 

100

 seconds.

Active OPC Server 

To control an input or output channel of a remote Ethernet I/O device 
running the most general Modbus/TCP protocol requires specifying 
the Modbus address of those input and output channels. This can take 
quite a bit of effort since you may need to look up the address and data 
type in the user’s manual for address mapping, and can also cause 
problems once the I/O channels change or a device is replaced. 

User-defined Modbus Addressing

The ioLogik E1200’s user-defined Modbus addressing offers the 
flexibility to make the Modbus address dynamic, and the address can 
be configured to be compatible with other Modbus devices. When a 
system is being replicated, or the filed I/O is being replaced, the user-
defined Modbus eliminates the effort of reconfiguring the PC control 
software or field controller. 

Mechanical Design

DIN and Wall Mountable

The ioLogik E1200 is designed with a vertical form factor, and can be 
used with both DIN-Rail and Wall Mounting.

Stress-relief for Solid Wiring

A stress-relief connector at the bottom of the ioLogik E1200 helps 
prevent the wiring from being pulled out.

Summary of Contents for ioLogik E1210

Page 1: ... Built in 2 port Ethernet switch for daisy chain topologies Free support of Moxa s push based Active OPC Server Lite Seamlessly connect to any SCADA system Save 80 on network bandwidth I O response that s seven times faster User defined Modbus TCP addressing MXIO programming library for Windows and WinCE VB VC NET and Linux C APIs Web configuration with Import Export function must be formed in a s...

Page 2: ...onnect to the next ioLogik in the daisy chain Applications such as factory automation security and surveillance systems and tunnel monitoring can make use of daisy chained Ethernet for building multi drop I O networks over standard Ethernet cables Many industrial automation users are familiar with the multi drop configuration typically used in fieldbus applications The daisy chain function on the ...

Page 3: ... O Test 2 I O Status ResponseTime This test used 128 ioLogik E2210 units with 2 560 I O points As shown in the figure the active architecture is 7 times better than the passive architecture in response time when the I O status changes Reduce Bandwidth Consumption by 80 Active Ethernet I O Passive Ethernet I O 0 1 2 3 4 5 0 1 2 3 4 5 6 7 7 Times Faster Active Ethernet I O Passive Ethernet I O archi...

Page 4: ... address table takes 100 seconds Active OPC Server To control an input or output channel of a remote Ethernet I O device running the most general Modbus TCP protocol requires specifying the Modbus address of those input and output channels This can take quite a bit of effort since you may need to look up the address and data type in the user s manual for address mapping and can also cause problems...

Page 5: ...ver current Limit 600 mA per channel Over temperature Shutdown 175 C typical 150 C min Output Current Rating Max 200 mA per channel Isolation 3K VDC or 2K Vrms Relay Output for ioLogik E1214 Type Form A N O relay outputs 5A Contact Rating 5 A 30 VDC 5 A 250 VAC 5 A 110 VAC Inductance Load 2 A Resistance Load 5 A Breakdown Voltage 500 VAC Relay On Off Time 1500 ms Max Initial Insulation Resistance ...

Page 6: ...NO 14 R2_C 15 R3_NO 16 R3_C 17 R4_NO 18 R4_C 19 R5_NO 20 R5_C 1 AI0 2 AI0 3 AI1 4 AI1 5 AI2 6 AI2 7 AI3 8 AI3 9 AI4 10 AI4 11 AI5 12 AI5 13 AI6 14 AI6 15 AI7 16 AI7 17 18 19 20 ioLogik E1214 top to bottom ioLogik E1240 top to bottom 1 COM0 2 DI0 3 DI1 4 DI2 5 DI3 6 GND 7 DI4 8 DI5 9 DI6 10 DI7 11 COM1 12 DIO0 13 DIO1 14 DIO2 15 DIO3 16 GND 17 DIO4 18 DIO5 19 DIO6 20 DIO7 ioLogik E1210 top to botto...

Reviews: